PET Performance Evaluation of an MR-Compatible PET Insert

被引:32
|
作者
Wu, Yibao [1 ]
Catana, Ciprian [2 ]
Farrell, Richard [3 ]
Dokhale, Purushottam A. [3 ]
Shah, Kanai S. [3 ]
Qi, Jinyi [1 ]
Cherry, Simon R. [1 ]
机构
[1] Univ Calif Davis, Dept Biomed Engn, Davis, CA 95616 USA
[2] Massachusetts Gen Hosp, Dept Radiol, Athinoula A Martinos Ctr Biomed Imaging, Charlestown, MA 02129 USA
[3] Radiat Monitoring Devices Inc, Watertown, MA 02472 USA
基金
美国国家卫生研究院;
关键词
Avalanche photodiodes; positron emission tomography (PET); magnetic resonance imaging (MRI); POSITRON-EMISSION-TOMOGRAPHY; SENSITIVE AVALANCHE PHOTODIODES; SMALL ANIMAL PET; SIMULTANEOUS PET/MRI; SCANNER; MICROPET; DETECTOR; DESIGN; ACQUISITION; RESOLUTION;
D O I
10.1109/TNS.2009.2015448
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A magnetic resonance (MR) compatible positron emission tomography (PET) insert has been developed in our laboratory for simultaneous small animal PET/MR imaging. This system is based on lutetium oxyorthosilicate (LSO) scintillator arrays with position-sensitive avalanche photodiode (PSAPD) photodetectors. The PET performance of this insert has been measured. The average reconstructed image spatial resolution was 1.51 mm. The sensitivity at the center of the field of view (CFOV) was 0.35%, which is comparable to the simulation predictions of 0.40%. The average photopeak energy resolution was 25%. The scatter fraction inside the MRI scanner with a line source was 12% (with a mouse-sized phantom and standard 35 mm Bruker 1H RF coil), 7% (with RF coil only) and 5% (without phantom or RF coil) for an energy window of 350-650 keV. The front-end electronics had a dead time of 390 ns, and a trigger extension dead time of 7.32 mu s that degraded counting rate performance for injected doses above similar to 0.75 mCi (28 MBq). The peak noise-equivalent count rate (NECR) of 1.27 kcps was achieved at 290 mu Ci (10.7 MBq). The system showed good imaging performance inside a 7-T animal MRI system; however improvements in data acquisition electronics and reduction of the coincidence timing window are needed to realize improved NECR performance.
引用
收藏
页码:574 / 580
页数:7
相关论文
共 50 条
  • [21] Design and development of an MR-Compatible PET scanner for imaging small animals
    Mackewn, JE
    Strul, D
    Hallett, WA
    Halsted, P
    Page, RA
    Keevil, SF
    Williams, SCR
    Cherry, SR
    Marsden, PK
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3271 - 3274
  • [22] Hybrid RCD-WTA Multiplexer for MR-compatible PET Detector
    Yang, Jingyu
    Lee, Minho
    Kang, Jihoon
    JOURNAL OF MAGNETICS, 2020, 25 (04) : 626 - 631
  • [23] Evaluation of a silicon photomultiplier PET insert for simultaneous PET and MR imaging
    Ko, Guen Bae
    Kim, Kyeong Yun
    Yoon, Hyun Suk
    Lee, Min Sun
    Son, Jeong-Whan
    Im, Hyung-Jun
    Lee, Jae Sung
    MEDICAL PHYSICS, 2016, 43 (01) : 72 - 83
  • [24] Feasibility of image fusion from MR and MR-compatible flexible PET: a pilot study
    Nakamoto, Ryusuke
    Nakamoto, Yuji
    Ishimori, Takayoshi
    Fushimi, Yasutaka
    Aki, Kido
    Togashi, Kaori
    JOURNAL OF NUCLEAR MEDICINE, 2017, 58
  • [25] Performance Evaluation of Magnetic Compatible PET Insert Scanner Prototype Using GATE
    Huang, Yanchao
    Lu, Lijun
    Feng, Qianjin
    2018 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE PROCEEDINGS (NSS/MIC), 2018,
  • [26] A Brain PET Insert MR Compatible: Final Design and First Results
    Gonzalez, Antonio J.
    Gonzalez-Montoro, Andrea
    Aguilar, Albert
    Conde, Pablo
    Canizares, Gabriel
    Hernandez, Liczandro
    Iborra, Amadeo
    Moliner, Laura
    Vidal, Luis F.
    Sanchez, Sebastian
    Sanchez, Filomeno
    Garcia, Reineiry
    Barbera, Julio
    Correcher, Carlos
    Aussenhofer, Sesbastian
    Gareis, Daniel
    Galasso, Matteo
    Fabbri, Andrea
    Preziosi, Enrico
    Visvikis, Dimitris
    Bert, Julien
    Autret, Awen
    Benlloch, Jose M.
    2016 IEEE NUCLEAR SCIENCE SYMPOSIUM, MEDICAL IMAGING CONFERENCE AND ROOM-TEMPERATURE SEMICONDUCTOR DETECTOR WORKSHOP (NSS/MIC/RTSD), 2016,
  • [27] PET Insert for PET/MR Brain Imaging
    不详
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (07) : 23N - 24N
  • [28] Development of a large area, high resolution, MR-compatible PET detector module
    Raylman, Raymond
    Majewski, Stan
    Stolin, Alexander
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [29] A Multi-Slice Dual Layer MR-Compatible Animal PET System
    Yamamoto, S.
    Hatazawa, J.
    Imaizumi, M.
    Shimosegawa, E.
    Aoki, M.
    Sugiyama, E.
    Kawakami, M.
    Takamatsu, S.
    Minato, K.
    Matsumoto, K.
    Senda, M.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2009, 56 (05) : 2706 - 2713
  • [30] Development of a SiPM Based MR-Compatible DOI-TOF-PET Detector
    Furumiya, Tetsuo
    Tsuda, Tomoaki
    Tonami, Hiromichi
    Satoh, Masanobu
    Nakazawa, Masayuki
    Ohi, Junichi
    Kitamura, Keishi
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,