No invasive measurement of urea in blood based in optical sensing for Hemodialysis treatments

被引:0
|
作者
Adolfo Martinez, Gustavo [1 ]
机构
[1] Tech Univ Catalonia, Biomed Engn Res Ctr, Barcelona, Spain
关键词
D O I
10.1109/IEMBS.2005.1616847
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The present work shows the development of a low-cost system to measure on-line blood urea concentration during dialysis procedures using optical sensor in the visible range. The objective in this project is obtaining the quantification of urea on-line during practices of the hemodialysis treatments. For which it has been considered to be a hypothesis that the dependence in the volume change of the red globules with the urea concentration in the blood is due to the changes to the osmotic pressure and to the mechanisms of regulation of the cellular volume. A bigger concentration of urea would imply a reduction of the volume of the cells and, therefore, a decrease of the optical absorbance. To validate this hypothesis, we used a simplified cellular model based on a yeast cell suspension. Measurements at urea concentrations using a custom single wavelength absorbance meter, and electrical impedance measurements system as contrast technique. Finally to validate this system have carried out thirty mensurations among diverse patient subject a Hemodialysis treatment in the Military Hospital Centre in Mexico, City.
引用
收藏
页码:1998 / 2001
页数:4
相关论文
共 50 条
  • [1] Measurement of blood urea based in optical sensing by employ in hemodialysis treatment
    Martinez, Gustavo Adolfo
    2006 28th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Vols 1-15, 2006, : 2812 - 2815
  • [2] On-Line Measurement of Blood Urea Based in Optical Sensing by Employ in Hemodialysis Treatment
    Adolfo Martinez, Gustavo
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 651 - +
  • [3] Non-invasive, optical measurement of absolute blood volume in hemodialysis patients
    Johnson, DW
    McMahon, M
    Campbell, S
    Wilkinson, J
    Kime, N
    Shannon, G
    Fleming, SJ
    KIDNEY INTERNATIONAL, 1996, 49 (01) : 255 - 260
  • [4] Study on optical measurement conditions for non-invasive blood glucose sensing
    Xu, KX
    Chen, WL
    Jiang, JY
    Qiu, QJ
    COMPLEX DYNAMICS, FLUCTUATIONS, CHAOS, AND FRACTALS IN BIOMEDICAL PHOTONICS, 2004, 5 (19): : 83 - 91
  • [5] Near-infrared spectroscopic measurement of urea in dialysate samples collected during hemodialysis treatments
    Eddy, CV
    Flanigan, M
    Arnold, MA
    APPLIED SPECTROSCOPY, 2003, 57 (10) : 1230 - 1235
  • [6] Noninvasive measurement of blood glucose based on optical sensing and internal standard method
    Morikawa, Tomotaka
    Saiki, Fujio
    Ishizawa, Hiroaki
    Toba, Eiji
    2006 SICE-ICASE INTERNATIONAL JOINT CONFERENCE, VOLS 1-13, 2006, : 5843 - +
  • [7] Noninvasive measurement of blood glucose based on optical sensing and internal standard method
    Saiki, Fujio
    Ishizawa, Hiroaki
    Muro, Akinobu
    Toba, Eiji
    PROCEEDINGS OF SICE ANNUAL CONFERENCE, VOLS 1-8, 2007, : 780 - 783
  • [8] Non-invasive tunnel convergence measurement based on distributed optical fiber strain sensing
    Piccolos, A.
    Lecieux, Y.
    Delepine-Lesoille, S.
    Leduc, D.
    SMART MATERIALS AND STRUCTURES, 2019, 28 (04)
  • [9] Non-invasive blood glucose measurement Application of near infrared optical measurement
    Anas, M. N.
    Syafirah, A.
    Norali, A. N.
    Normahira, M.
    2012 IEEE Conference on Sustainable Utilization and Development in Engineering and Technology (STUDENT), 2012, : 258 - 261
  • [10] Optical flow sensor for continuous invasive measurement of blood flow velocity
    Ruiz-Vargas, Albert
    Morris, Scott A.
    Hartley, Richard H.
    Arkwright, John W.
    JOURNAL OF BIOPHOTONICS, 2019, 12 (10)