No invasive measurement of urea in blood based in optical sensing for Hemodialysis treatments

被引:0
|
作者
Adolfo Martinez, Gustavo [1 ]
机构
[1] Tech Univ Catalonia, Biomed Engn Res Ctr, Barcelona, Spain
关键词
D O I
10.1109/IEMBS.2005.1616847
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The present work shows the development of a low-cost system to measure on-line blood urea concentration during dialysis procedures using optical sensor in the visible range. The objective in this project is obtaining the quantification of urea on-line during practices of the hemodialysis treatments. For which it has been considered to be a hypothesis that the dependence in the volume change of the red globules with the urea concentration in the blood is due to the changes to the osmotic pressure and to the mechanisms of regulation of the cellular volume. A bigger concentration of urea would imply a reduction of the volume of the cells and, therefore, a decrease of the optical absorbance. To validate this hypothesis, we used a simplified cellular model based on a yeast cell suspension. Measurements at urea concentrations using a custom single wavelength absorbance meter, and electrical impedance measurements system as contrast technique. Finally to validate this system have carried out thirty mensurations among diverse patient subject a Hemodialysis treatment in the Military Hospital Centre in Mexico, City.
引用
收藏
页码:1998 / 2001
页数:4
相关论文
共 50 条
  • [21] NON-INVASIVE OPTICAL ESTIMATION OF INTRADIALYTIC CONCENTRATIONS OF UREMIC TOXINS IN BLOOD OF HEMODIALYSIS PATIENTS
    Paats, Joosep
    Adoberg, Annika
    Arund, Jurgen
    Fridolin, Ivo
    Holmar, Jana
    Lauri, Kai
    Leis, Liisi
    Pilt, Kristjan
    Tanner, Risto
    Luman, Merike
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2023, 38 : I149 - I150
  • [22] Blood pressure measurement in hemodialysis patients
    Lazar, AE
    Smith, MC
    Rahman, M
    SEMINARS IN DIALYSIS, 2004, 17 (04) : 250 - 254
  • [23] Blood pressure measurement in hemodialysis: The importance of the measurement technique
    Kubrusly, M.
    Costa de Oliveira, Claudia Maria
    Silva, R. P.
    Pinheiro, M. A.
    Rocha, M. B. C.
    Magalhaes, R. M.
    SAUDI JOURNAL OF KIDNEY DISEASES AND TRANSPLANTATION, 2016, 27 (02) : 241 - 249
  • [24] Online measurement of urea concentration in spent dialysate during hemodialysis
    Olesberg, JT
    Armitage, B
    Arnold, MA
    Flanigan, MJ
    OPTICAL DIAGNOSTICS AND SENSING OF BIOLOGICAL FLUIDS AND GLUCOSE AND CHOLESTEROL MONITORING II, 2002, 4624 : 95 - 105
  • [25] Online measurement of urea concentration in spent dialysate during hemodialysis
    Olesberg, JT
    Arnold, MA
    Flanigan, MJ
    CLINICAL CHEMISTRY, 2004, 50 (01) : 175 - 181
  • [26] Kinetics of urea and β2-microglobulin during and after short hemodialysis treatments
    Leypoldt, JK
    Cheung, AK
    Deeter, RB
    Goldfarb-Rumyantzev, A
    Greene, T
    Depner, TA
    Kusek, J
    KIDNEY INTERNATIONAL, 2004, 66 (04) : 1669 - 1676
  • [27] Non-Invasive Potentiometric Sensor for Measurement of Blood Urea in Human Subjects Using Reverse Iontophoresis
    Varadharaj, Eswaramoorthy K.
    Jampana, Nagaraju
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2016, 163 (07) : B340 - B347
  • [28] Smartphone-based optical blood pressure monitoring in the acute care setting: Accuracy compared to invasive blood pressure measurement.
    Gregory, Hofmann
    Jean, Degott
    Raoul, Schorer
    Guillaume, Bonnier
    Martin, Proenca
    Patrick, Schoettker
    SWISS MEDICAL WEEKLY, 2020, : 3S - 3S
  • [29] Non-invasive Optical Sensing Method Based on Random Lasing
    Tommasi, Federico
    Fini, Lorenzo
    Ignesti, Emilio
    Martelli, Fabrizio
    Cavalieri, Stefano
    2019 PHOTONICS & ELECTROMAGNETICS RESEARCH SYMPOSIUM - SPRING (PIERS-SPRING), 2019, : 219 - 222
  • [30] Advancement in glucose concentration measurement in human blood: a surface plasmon resonance-based optical sensing approach
    Bisht, Sagar
    Singh, Anshuman
    Kushwah, Himanshu
    Pratap, Yogesh
    JOURNAL OF OPTICS-INDIA, 2024,