On-Line Measurement of Blood Urea Based in Optical Sensing by Employ in Hemodialysis Treatment

被引:0
|
作者
Adolfo Martinez, Gustavo [1 ]
机构
[1] Mil Hosp Ctr, Mexico City, DF, Mexico
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The present paper shows the design and development the On-line measure system of the blood urea concentration during dialysis procedures, using non-invasive technical by employ the optical sensing in the visible range. Previous results obtained in Military Hospital Centre in Mexico displayed experimental evidence of a clear correlation between blood urea contents and optical absorbance in the red region obtained through the arterial line in hemodialysis machine. Our hypothesis considers that the cause of this dependence is the volume change of the red cells with the urea concentration due to the osmotic pressure and to the mechanisms of regulation of the cellular volume. The reduction of the volume of the cells would lead to a decrease of the optical absorbance. Measurements were first performed during experimental dialysis procedures, clinical measurements were carried out on a group of patients during hemodialysis procedures in Mexico City. The most relevant interfering parameter was the water extraction along the dialysis treatment, given that changes in the blood fluid and arterial pressure (Hypotention or Hypertention), thus affecting the measurement principle.
引用
收藏
页码:651 / +
页数:3
相关论文
共 50 条
  • [1] Measurement of blood urea based in optical sensing by employ in hemodialysis treatment
    Martinez, Gustavo Adolfo
    2006 28th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Vols 1-15, 2006, : 2812 - 2815
  • [2] Recirculation in vascular access for hemodialysis treatment by employ the on-line mesuring sytem of urea in blood
    Adolfo Martinez, Gustavo
    2008 INTERNATIONAL SPECIAL TOPIC CONFERENCE ON INFORMATION TECHNOLOGY AND APPLICATIONS IN BIOMEDICINE, VOLS 1 AND 2, 2008, : 24 - 28
  • [3] No invasive measurement of urea in blood based in optical sensing for Hemodialysis treatments
    Adolfo Martinez, Gustavo
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 1998 - 2001
  • [4] On-line slippage measurement system for optical fiber sensing array
    Liu, Chunhui
    Liu, Zhichao
    Yin, Lixin
    Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering, 2022, 51 (03):
  • [5] An Optical Fiber Sensing System for On-line Measurement of Soil Properties
    Yang, Haiqing
    Lv, Gang
    MATERIALS SCIENCE AND ENGINEERING, PTS 1-2, 2011, 179-180 : 1314 - 1317
  • [6] The on-line urea sensor: A useful method for hemodialysis prescription
    Almirall, J
    Jurkiewicz, M
    Garcia, M
    Sole, S
    Liesa, A
    Padilla, J
    Yuste, E
    Alegret, S
    MartinezFabregas, E
    NEFROLOGIA, 1996, 16 (06): : 524 - 530
  • [7] Manometric biosensor for on-line measurement of milk urea
    Jenkins, DM
    Delwiche, MJ
    BIOSENSORS & BIOELECTRONICS, 2002, 17 (6-7): : 557 - 563
  • [8] Modelling on-line urea sensor-measurements during hemodialysis
    Thomaseth, K
    Garred, L
    Ingegno, M
    Berti, M
    Pacini, G
    PROCEEDINGS OF THE 18TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 18, PTS 1-5, 1997, 18 : 1816 - 1817
  • [9] Factors affecting the application of on-line milk urea sensing
    Jenkins, DM
    Delwiche, MJ
    DePeters, EJ
    BonDurant, RH
    TRANSACTIONS OF THE ASAE, 2002, 45 (05): : 1687 - 1695
  • [10] Factors affecting the application of on-line milk urea sensing
    Jenkins, Daniel M.
    Delwiche, Michael J.
    DePeters, Edward J.
    BonDurant, Robert H.
    1687, American Society of Agricultural and Biological Engineers (45):