Characterization of and correction for artifacts in linogram MRI

被引:5
|
作者
Gai, N [1 ]
Axel, L [1 ]
机构
[1] HOSP UNIV PENN,DEPT RADIOL,PHILADELPHIA,PA 19104
关键词
linogram MRI; field inhomogeneity; gradient nonlinearity; chemical-shift;
D O I
10.1002/mrm.1910370223
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Chemical shift differences, field inhomogeneity, and gradient nonlinearity result in artifacts in magnetic resonance imaging. Three artifacts are characterized for linogram imaging and it is shown that, based on computer simulations and theory, linogram MRI behaves similarly to 2DFT. A correction technique similar to a scheme for 2DFT imaging based on the Dixon technique and coordinate transform methods is proposed. The algorithm is applied to correct for field inhomogeneity and gradient nonlinearity-induced artifacts in both simulations and images of a clinical phantom. The results show good correlation with the theory. It is concluded that linogram imaging offers certain attractive features of both 2DFT and PR imaging techniques, and is a potentially viable alternative to PR imaging in the presence of field inhomogeneity.
引用
收藏
页码:275 / 284
页数:10
相关论文
共 50 条
  • [41] Automatic Correction of Motion Artifacts in 4D Left Ventricle Model Reconstructed from MRI
    Su, Yi
    Tan, May-Ling
    Lim, Chi-Wan
    Teo, Soo-Kng
    Selvaraj, Senthil Kumar
    Wan, Min
    Zhong, Liang
    Tan, Ru-San
    2014 COMPUTING IN CARDIOLOGY CONFERENCE (CINC), VOL 41, 2014, 41 : 705 - 708
  • [42] SIMULTANEOUS BAYESIAN CORRECTION OF SLAB BOUNDARY ARTIFACTS AND BIAS FIELD FOR HIGH RESOLUTION EX VIVO MRI
    Iglesias, J. E.
    Paz-Alonso, P.
    Lerma-Usabiaga, G.
    Insausti, R.
    Miller, K.
    Caballero-Gaudes, C.
    2016 IEEE 13TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2016, : 1384 - 1387
  • [43] Adaptive retrospective correction of motion artifacts in cranial MRI with multicoil three-dimensional radial acquisitions
    Anderson, Ashley G., III
    Velikina, Julia
    Block, Walter
    Wieben, Oliver
    Samsonov, Alexey
    MAGNETIC RESONANCE IN MEDICINE, 2013, 69 (04) : 1094 - 1103
  • [44] BEST IN PHYSICS (IMAGING) - Novel Correction of Signal Modulation and Motion Artifacts in Temporal Bone BSSFP MRI
    Hoff, M.
    Xiang, Q.
    Wilson, G.
    Andre, J.
    MEDICAL PHYSICS, 2014, 41 (06) : 439 - +
  • [45] A Variational Image-Based Approach to the Correction of Susceptibility Artifacts in the Alignment of Diffusion Weighted and Structural MRI
    Tao, Ran
    Fletcher, P. Thomas
    Gerber, Samuel
    Whitaker, Ross T.
    INFORMATION PROCESSING IN MEDICAL IMAGING, PROCEEDINGS, 2009, 5636 : 664 - +
  • [46] Metal-Induced Artifacts in MRI
    Hargreaves, Brian A.
    Worters, Pauline W.
    Pauly, Kim Butts
    Pauly, John M.
    Koch, Kevin M.
    Gold, Garry E.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 197 (03) : 547 - 555
  • [47] EYE ARTIFACTS FROM MASCARA IN MRI
    WRIGHT, RM
    SWIETEK, PA
    SIMMONS, ML
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1985, 6 (04) : 652 - 652
  • [48] Artifacts Quantification of Metal Implants in MRI
    Vrachnis, I. N.
    Vlachopoulos, G. F.
    Maris, T. G.
    Costaridou, L. I.
    INTERNATIONAL CONFERENCE ON BIO-MEDICAL INSTRUMENTATION AND RELATED ENGINEERING AND PHYSICAL SCIENCES (BIOMEP 2017), 2017, 931
  • [49] MASCARA AND EYELINING TATTOOS - MRI ARTIFACTS
    WEISS, RA
    SAINTLOUIS, LA
    HAIK, BG
    MCCORD, CD
    TAVERAS, JL
    ANNALS OF OPHTHALMOLOGY, 1989, 21 (04): : 129 - 131
  • [50] Automatic compensation of motion artifacts in MRI
    Atkinson, D
    Hill, DLG
    Stoyle, PNR
    Summers, PE
    Clare, S
    Bowtell, R
    Keevil, SF
    MAGNETIC RESONANCE IN MEDICINE, 1999, 41 (01) : 163 - 170