Characterization of and correction for artifacts in linogram MRI

被引:5
|
作者
Gai, N [1 ]
Axel, L [1 ]
机构
[1] HOSP UNIV PENN,DEPT RADIOL,PHILADELPHIA,PA 19104
关键词
linogram MRI; field inhomogeneity; gradient nonlinearity; chemical-shift;
D O I
10.1002/mrm.1910370223
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Chemical shift differences, field inhomogeneity, and gradient nonlinearity result in artifacts in magnetic resonance imaging. Three artifacts are characterized for linogram imaging and it is shown that, based on computer simulations and theory, linogram MRI behaves similarly to 2DFT. A correction technique similar to a scheme for 2DFT imaging based on the Dixon technique and coordinate transform methods is proposed. The algorithm is applied to correct for field inhomogeneity and gradient nonlinearity-induced artifacts in both simulations and images of a clinical phantom. The results show good correlation with the theory. It is concluded that linogram imaging offers certain attractive features of both 2DFT and PR imaging techniques, and is a potentially viable alternative to PR imaging in the presence of field inhomogeneity.
引用
收藏
页码:275 / 284
页数:10
相关论文
共 50 条
  • [31] Inadequacy of motion correction algorithms in functional MRI: Role of susceptibility-induced artifacts
    Wu, DH
    Lewin, JS
    Duerk, JL
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (02): : 365 - 370
  • [32] Real-time correction by optical tracking with integrated geometric distortion correction for reducing motion artifacts in functional MRI
    Rotenberg, David
    Chiew, Mark
    Ranieri, Shawn
    Tam, Fred
    Chopra, Rajiv
    Graham, Simon J.
    MAGNETIC RESONANCE IN MEDICINE, 2013, 69 (03) : 734 - 748
  • [33] Automatic correction of in-plane bulk motion artifacts in self-navigated radial MRI
    Kim, Sungheon
    Dougherty, Lawrence
    Rosen, Mark A.
    Song, Hee Kwon
    Poptani, Harish
    MAGNETIC RESONANCE IMAGING, 2008, 26 (03) : 367 - 378
  • [34] Correction of metal-induced susceptibility artifacts for functional MRI during deep brain stimulation
    In, Myung-Ho
    Cho, Shinho
    Shu, Yunhong
    Min, Hoon-Ki
    Bernstein, Matt A.
    Speck, Oliver
    Lee, Kendall H.
    Jo, Hang Joon
    NEUROIMAGE, 2017, 158 : 26 - 36
  • [35] Characterization and correction of cardiovascular motion artifacts in diffusion-weighted imaging of the pancreas
    Geng, Ruiqi
    Zhang, Yuxin
    Starekova, Jitka
    Rutkowski, David R.
    Estkowski, Lloyd
    Roldan-Alzate, Alejandro
    Hernando, Diego
    MAGNETIC RESONANCE IN MEDICINE, 2021, 86 (04) : 1956 - 1969
  • [36] Artifacts and pitfalls in diffusion MRI
    Le Bihan, Denis
    Poupon, Cyril
    Amadon, Alexis
    Lethimonnier, Franck
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 24 (03) : 478 - 488
  • [37] Imaging Artifacts in MRI Simulators
    Carrasco, S.
    Huete, I.
    Zunino, R.
    NEURORADIOLOGY JOURNAL, 2011, 24 (04): : 547 - 550
  • [38] Harmonic analysis for the characterization and correction of geometric distortion in MRI
    Tadic, Tony
    Jaffray, David A.
    Stanescu, Teodor
    MEDICAL PHYSICS, 2014, 41 (11)
  • [39] A linogram/sinogram cross-correlation method for motion correction in planar and SPECT imaging
    Sarkar, Saeed
    Oghabian, Mohammad A.
    Mohammadi, Iraj
    Mohammadpour, Alireza
    Rahmim, Arman
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2007, 54 (01) : 71 - 79
  • [40] Correction of voxelization artifacts by revoxelization
    Srámek, M
    Dimitrov, LI
    Bærentzen, JA
    VOLUME GRAPHICS 2001, 2001, : 265 - 275