Personalized glucose-insulin model based on signal analysis

被引:4
|
作者
Goede, Simon L. [1 ]
de Galan, Bastiaan E. [2 ]
Leow, Melvin Khee Shing [3 ,4 ]
机构
[1] Syst Res, Oterlekerweg 4, NL-1841 GP Stompetoren, Netherlands
[2] Radboud Univ Nijmegen, Med Ctr, Dept Gen Internal Med, Postbus 9101, NL-6500 HB Nijmegen, Netherlands
[3] Tan Tock Seng Hosp, Dept Endocrinol, Singapore 308433, Singapore
[4] Nanyang Technol Univ, Off Clin Sci, Duke NUS Grad Med Sch, Singapore Lee Kong Chian Sch Med, Singapore, Singapore
关键词
Appearance profile; Model identification; Electrical network model; Simulation; Personalized target; Validation;
D O I
10.1016/j.jtbi.2016.12.018
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Glucose plasma measurements for diabetes patients are generally presented as a glucose concentration-time profile with 15-60 min time scale intervals. This limited resolution obscures detailed dynamic events of glucose appearance and metabolism. Measurement intervals of 15 min or more could contribute to imperfections in present diabetes treatment. High resolution data from mixed meal tolerance tests (MMTT) for 24 type 1 and type 2 diabetes patients were used in our present modeling. We introduce a model based on the physiological properties of transport, storage and utilization. This logistic approach follows the principles of electrical network analysis and signal processing theory. The method mimics the physiological equivalent of the glucose homeostasis comprising the meal ingestion, absorption via the gastrointestinal tract (GIT) to the endocrine nexus between the liver, pancreatic alpha and beta cells. This model demystifies the metabolic 'black box' by enabling in silico simulations and fitting of individual responses to clinical data. Five-minute intervals MMIT data measured from diabetic subjects result in two independent model parameters that characterize the complete glucose system response at a personalized level. From the individual data measurements, we obtain a model which can be analyzed with a standard electrical network simulator for diagnostics and treatment optimization. The insulin dosing time scale can be accurately adjusted to match the individual requirements of characterized diabetic patients without the physical burden of treatment.
引用
收藏
页码:333 / 342
页数:10
相关论文
共 50 条
  • [41] Multi-Step Approach for Sensitivity Analysis for a Unified Model of Glucose-Insulin Metabolism
    Tolks, Christian
    Ament, Christoph
    Eberle, Claudia
    IFAC PAPERSONLINE, 2020, 53 (02): : 16394 - 16399
  • [42] Global stability in a model of the glucose-insulin interaction with time delay
    Bennett, DL
    Gourley, SA
    EUROPEAN JOURNAL OF APPLIED MATHEMATICS, 2004, 15 : 203 - 221
  • [43] Investigation of Glucose-Insulin Model Efficacy for Diabetes Patient in the ICU
    Razak, Athirah Abdul
    Abu-Samah, Asma
    Razak, Normy N.
    Ahamad, Nurhamim
    Suhaimi, Fatanah M.
    Jamaludin, Ummu K.
    Ralib, Azrina Md
    Mat-Nor, M. B.
    2ND INTERNATIONAL CONFERENCE FOR INNOVATION IN BIOMEDICAL ENGINEERING AND LIFE SCIENCES, 2018, 67 : 177 - 181
  • [44] Delay-induced uncertainty for a paradigmatic glucose-insulin model
    Karamched, Bhargav
    Hripcsak, George
    Albers, David
    Ott, William
    CHAOS, 2021, 31 (02)
  • [45] A new application of fractional glucose-insulin model and numerical solutions
    Ozturk, Zafer
    Bilgil, Halis
    Sorgun, Sezer
    SIGMA JOURNAL OF ENGINEERING AND NATURAL SCIENCES-SIGMA MUHENDISLIK VE FEN BILIMLERI DERGISI, 2024, 42 (02): : 407 - 413
  • [46] A RELEVANT GLUCOSE-INSULIN MODEL: VALIDATION USING CLINICAL DATA
    Magdelaine, N.
    Chaillous, L.
    Guilhem, I.
    Poirier, J. Y.
    Krempf, M.
    Guilloux, A. L. Fournier
    Moog, C.
    Le Carpentier, E.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2016, 18 : A93 - A94
  • [47] Estimation and SVM classification of glucose-insulin model parameters from OGTT data: a comparison with the ADA criteria Estimation and SM classification of glucose-insulin model parameters
    Vargas, Paola
    Moreles, Miguel Angel
    Pena, Joaquin
    Monroy, Adriana
    Alavez, Silvestre
    INTERNATIONAL JOURNAL OF DIABETES IN DEVELOPING COUNTRIES, 2021, 41 (01) : 54 - 62
  • [48] A Hardware Acceleration Based on High-Level Synthesis Approach for Glucose-Insulin Analysis
    Daud, Nur Atikah Mohd
    Mahmud, Farhanahani
    Jabbar, Muhamad Hairol
    INTERNATIONAL CONFERENCE ON ENGINEERING, SCIENCE AND NANOTECHNOLOGY 2016 (ICESNANO 2016), 2017, 1788
  • [49] SYSTEMS-ANALYSIS AND GLUCOSE-INSULIN CONTROL-SYSTEM
    ATKINS, G
    CLINICAL SCIENCE AND MOLECULAR MEDICINE, 1974, 46 (06): : P27 - P27
  • [50] Analysis of IVGTT glucose-insulin interaction models with time delay
    Li, JX
    Kuang, Y
    Li, BT
    DISCRETE AND CONTINUOUS DYNAMICAL SYSTEMS-SERIES B, 2001, 1 (01): : 103 - 124