Personalized glucose-insulin model based on signal analysis

被引:4
|
作者
Goede, Simon L. [1 ]
de Galan, Bastiaan E. [2 ]
Leow, Melvin Khee Shing [3 ,4 ]
机构
[1] Syst Res, Oterlekerweg 4, NL-1841 GP Stompetoren, Netherlands
[2] Radboud Univ Nijmegen, Med Ctr, Dept Gen Internal Med, Postbus 9101, NL-6500 HB Nijmegen, Netherlands
[3] Tan Tock Seng Hosp, Dept Endocrinol, Singapore 308433, Singapore
[4] Nanyang Technol Univ, Off Clin Sci, Duke NUS Grad Med Sch, Singapore Lee Kong Chian Sch Med, Singapore, Singapore
关键词
Appearance profile; Model identification; Electrical network model; Simulation; Personalized target; Validation;
D O I
10.1016/j.jtbi.2016.12.018
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Glucose plasma measurements for diabetes patients are generally presented as a glucose concentration-time profile with 15-60 min time scale intervals. This limited resolution obscures detailed dynamic events of glucose appearance and metabolism. Measurement intervals of 15 min or more could contribute to imperfections in present diabetes treatment. High resolution data from mixed meal tolerance tests (MMTT) for 24 type 1 and type 2 diabetes patients were used in our present modeling. We introduce a model based on the physiological properties of transport, storage and utilization. This logistic approach follows the principles of electrical network analysis and signal processing theory. The method mimics the physiological equivalent of the glucose homeostasis comprising the meal ingestion, absorption via the gastrointestinal tract (GIT) to the endocrine nexus between the liver, pancreatic alpha and beta cells. This model demystifies the metabolic 'black box' by enabling in silico simulations and fitting of individual responses to clinical data. Five-minute intervals MMIT data measured from diabetic subjects result in two independent model parameters that characterize the complete glucose system response at a personalized level. From the individual data measurements, we obtain a model which can be analyzed with a standard electrical network simulator for diagnostics and treatment optimization. The insulin dosing time scale can be accurately adjusted to match the individual requirements of characterized diabetic patients without the physical burden of treatment.
引用
收藏
页码:333 / 342
页数:10
相关论文
共 50 条
  • [31] Extension of the Bergman minimal model for the glucose-insulin interaction
    Department of Control Engineering and Information Technology, Budapest University of Technology and Economics, Magyar Tudósok kit. 2, H-1117 Budapest, Hungary
    Period Polytech Electr Eng, 2006, 1-2 (23-32):
  • [32] A Mobile Platform for Model-based Monitoring of Glucose-Insulin Homeostasis for Diabetics
    Tolks, Christian
    Ament, Christoph
    Eberle, Claudia
    2018 IEEE/ACM INTERNATIONAL CONFERECE ON CONNECTED HEALTH: APPLICATIONS, SYSTEMS AND ENGINEERING TECHNOLOGIES (CHASE), 2018, : 15 - 16
  • [33] A Simulation Model of Glucose-Insulin Metabolism and Implementation on OSG
    Rad, Milad Ghiasi
    Immaneni, Aditya
    McCabe, Megan
    Pierobon, Massimiliano
    Cui, Juan
    2017 IEEE INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICINE (BIBM), 2017, : 1832 - 1839
  • [34] Modelling glucose-insulin feedback signal interchanges involving β-cells with delays
    Sarika, Warunee
    Lenbury, Yongwimon
    Kumnungkit, Kanchana
    Kunphasuruang, Wannapa
    SCIENCEASIA, 2008, 34 (01): : 77 - 86
  • [35] Study of the glucose-insulin equivalent
    Bouckaert, JP
    Stricker, W
    COMPTES RENDUS DES SEANCES DE LA SOCIETE DE BIOLOGIE ET DE SES FILIALES, 1924, 91 : 100 - 102
  • [36] An LMI-Based Controller for the Glucose-Insulin System
    Latafat, P.
    Palumbo, P.
    Pepe, P.
    Kovacs, L.
    Panunzi, S.
    De Gaetano, A.
    2015 EUROPEAN CONTROL CONFERENCE (ECC), 2015, : 7 - 12
  • [37] Estimation and SVM classification of glucose-insulin model parameters from OGTT data: a comparison with the ADA criteriaEstimation and SM classification of glucose-insulin model parameters
    Paola Vargas
    Miguel Angel Moreles
    Joaquin Peña
    Adriana Monroy
    Silvestre Alavez
    International Journal of Diabetes in Developing Countries, 2021, 41 : 54 - 62
  • [38] Application of the Integrated Glucose-Insulin Model to the Graded Glucose Infusion and Glucose Clamp Studies
    Fancourt, Craig
    Gao, Wei
    Bosch, Rolien
    Valiathan, Chandni
    Vargo, Ryan
    Kothare, Prajakti
    Post, Teun
    JOURNAL OF PHARMACOKINETICS AND PHARMACODYNAMICS, 2014, 41 : S92 - S92
  • [39] Dynamical analysis of a nonlinear model for glucose-insulin system incorporating delays and β-cells compartment
    Chuedoung, Meechoke
    Sarika, Warunee
    Lenbury, Yongwimon
    NONLINEAR ANALYSIS-THEORY METHODS & APPLICATIONS, 2009, 71 (12) : E1048 - E1058
  • [40] Analysis of physical activity effects on plasma glucose-insulin system dynamics: A mathematical model
    Ntaganda, Jean Marie
    Minani, Froduald
    Banzi, Wellars
    Mpinganzima, Lydie
    Niyobuhungiro, Japhet
    Dusabejambo, Vincent
    Kambutse, Immaculate
    Rutaganda, Eric
    TRANSACTIONS OF THE INSTITUTE OF MEASUREMENT AND CONTROL, 2021, 43 (14) : 3272 - 3281