Analysis of HPM Pulse with Use of Data Base

被引:0
|
作者
Bugaj, Marek [1 ]
Przesmycki, Rafal [1 ]
机构
[1] Mil Univ Technol, Fac Elect, Gen S Kaliskiego 2 Str, PL-00908 Warsaw, Poland
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
With the development of technology there are more and more electronic devices and as a consequence there are more and more opportunities of negative influence of electromagnetic waves on their proper work. High Power Microwave (HPM) are increasingly used to interrupt or even destroy electronic devices. This article proposes a database to determine the distance from which the HPM was generated. The article presents database suggestions that will help you determine the distance from which the HPM pulse has been generated. The paper presents proposals for a measuring station for generation and measurement of HPM pulses. Discuss the usage of the HPM generator and the concepts of database creation. The paper presents the results of the measurement of the impulse of the HPP DS from different distances and the results of comparative analysis for the measurements performed from the reference pulse base.
引用
收藏
页码:975 / 980
页数:6
相关论文
共 50 条
  • [21] SIMULATION OF DATA BASE OPERATIONS IN A SYSTEM FOR DATA BASE DESIGN AND ANALYSIS.
    Greenleaf, John E.
    Petry, Frederick E.
    1978, : 30 - 1
  • [22] USE OF A DATA-BASE FOR COMPILATION OF DICTIONARIES
    MELNIKOVA, MM
    SMIRNOV, IP
    CHERKASOVA, GM
    NAUCHNO-TEKHNICHESKAYA INFORMATSIYA SERIYA 1-ORGANIZATSIYA I METODIKA INFORMATSIONNOI RABOTY, 1988, (06): : 21 - &
  • [23] Quick Guides for Use of the CompOSE Data Base
    Dexheimer, Veronica
    Mancini, Marco
    Oertel, Micaela
    Providencia, Constanca
    Tolos, Laura
    Typel, Stefan
    PARTICLES, 2022, 5 (03) : 346 - 360
  • [24] A Survey Data Base Use by SRS Members
    Raso, V. J.
    Sanders, J.
    Kumar, D.
    Knight, R.
    Burton, D.
    Bowen, R.
    Spratt, K.
    RESEARCH INTO SPINAL DEFORMITIES 8, 2012, 176 : 491 - 491
  • [25] Material permittivity measurement with the use of HPM pulses
    Rudyk, Karol
    Kubacki, Roman
    Kuchta, Marek
    PRZEGLAD ELEKTROTECHNICZNY, 2021, 97 (01): : 185 - 187
  • [26] HPM Detection System for Mobile and Stationary Use
    Adami, Christian
    Braun, Christian
    Clemens, Peter
    Suhrke, Michael
    Schmidt, H. U.
    Taenzer, Achim
    10TH INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY, 2011, : 1 - 6
  • [27] Statistical characteristics and inheritance analysis of signals between WB-HPM pulse and field-to-cable coupling
    Zhong, L. Q.
    Cai, J. L.
    Huang, H.
    Lin, J. C.
    Qin, F.
    Zhao, G.
    AOPC 2019: OPTICAL SENSING AND IMAGING TECHNOLOGY, 2019, 11338
  • [28] State parameter data base for MIPAS data analysis
    Kiefer, M
    von Clarmann, T
    Grabowski, U
    EARTH'S ATMOSPHERE, OCEAN AND SURFACE STUDIES, 2002, 30 (11): : 2387 - 2392
  • [29] Data Base Analysis using a Compact Data Set
    Ferrnando Kuri-Morales, Angel
    2014 IEEE INTERNATIONAL CONGRESS ON BIG DATA (BIGDATA CONGRESS), 2014, : 227 - 233
  • [30] ANALYSIS OF A REPLICATED DATA-BASE
    NELSON, RD
    IYER, BR
    PERFORMANCE EVALUATION, 1985, 5 (03) : 133 - 148