Automating the correction of flow integration drift during whole-body plethysmography

被引:0
|
作者
Stucky, Frederic [1 ]
Cazzaniga, Giacomo [2 ]
Aliverti, Andrea [2 ]
Kayser, Bengt [1 ]
Uva, Barbara [1 ]
机构
[1] Univ Lausanne, Inst Sport Sci, CH-1015 Lausanne, Switzerland
[2] Politecn Milan, Dipartimento Bioingn, I-20133 Milan, Italy
来源
42ND ANNUAL INTERNATIONAL CONFERENCES OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY: ENABLING INNOVATIVE TECHNOLOGIES FOR GLOBAL HEALTHCARE EMBC'20 | 2020年
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Prolonged measurement of total body volume variations (deltaVb) with whole-body, flow-based plethysmography (WBP) results in a drift of the signal due to changes in temperature and humidity inside the plethysmograph and to numerical integration of the flow to obtain deltaVb. This drift has been previously corrected with the application of a wavelet-based filter using visual inspection of the signal to select the optimal filter level (Uva et al. Front. Physiol. 6:411, 2016), thus introducing potential operator bias. To exclude the latter we compared this approach with a newly developed automatic method based on (1) correction for actual changes in temperature and humidity inside the plethysmograph (algorithm TH) and (2) automatic selection of the wavelet filter level based on comparison between deltaVb and intra-thoracic and abdominal pressure variations measured simultaneously (algorithm WAV). The Pearson's correlation coefficient between deltaVb and the changes in volume of the chest wall (deltaVcw) simultaneously obtained by optoelectronic plethysmography (OEP) was calculated after correction of deltaVb with TH and WAV applied separately, TH andWAV applied consecutively (TH+WAV), manual selection of a wavelet filter based on visual inspection (MAN) or no correction (CTRL). The correlation between deltaVb and deltaVcw increased marginally with WAV, TH+WAV and MAN compared to CTRL ( P < 0.01). Conversely, TH alone yielded a lower correlation (P < 0.01). It follows that while the automated wavelet filter level selection method (WAV) represents an effective, operator-independent method for the correction of deltaVb, whether or not it is combined with specific correction for changes in thermodynamic conditions inside the plethysmograph, the manual method (MAN) yields satisfactory results without the constraints of intra-thoracic and abdominal pressure measurement.
引用
收藏
页码:5 / 8
页数:4
相关论文
共 50 条
  • [42] Measuring Respiratory Function in Mice Using Unrestrained Whole-body Plethysmography
    Lim, Rebecca
    Zavou, Marcus J.
    Milton, Phillipa-Louise
    Chan, Siow Teng
    Tan, Jean L.
    Dickinson, Hayley
    Murphy, Sean V.
    Jenkin, Graham
    Wallace, Euan M.
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2014, (90):
  • [43] Whole-body Plethysmography in African Green Monkeys (Chlorocebus aethiops) with and without Jackets
    Foster, Chad D.
    Hunter, Ty C.
    Gibbs, Paul H.
    Leffel, Elizabeth K.
    JOURNAL OF THE AMERICAN ASSOCIATION FOR LABORATORY ANIMAL SCIENCE, 2008, 47 (05): : 52 - 55
  • [44] Evaluation of pulmonary function in European land tortoises using whole-body plethysmography
    Schifino Valente, A. L.
    Martinez-Silvestre, A.
    Garcia-Guasch, L.
    Riera-Tort, A.
    Marco, I.
    Lavin, S.
    Cuenca, R.
    VETERINARY RECORD, 2012, 171 (06) : 154 - +
  • [45] ONLINE MEASUREMENT, MODELING AND GRAPHIC PROCESSING OF SIGNALS OBTAINED BY WHOLE-BODY PLETHYSMOGRAPHY
    ADAMEC, M
    CETTL, L
    FELKEL, H
    BULLETIN EUROPEEN DE PHYSIOPATHOLOGIE RESPIRATOIRE-CLINICAL RESPIRATORY PHYSIOLOGY, 1985, 21 : 11 - 11
  • [46] Pulmonary function assessment by whole-body plethysmography in restrained versus unrestrained mice
    DeLorme, MP
    Moss, OR
    JOURNAL OF PHARMACOLOGICAL AND TOXICOLOGICAL METHODS, 2002, 47 (01) : 1 - 10
  • [47] ELECTROCORTICOGRAM DURING WHOLE-BODY VIBRATION
    NICHOLSO.AN
    GUIGNARD, JC
    ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1965, 19 (01): : 103 - &
  • [48] ANESTHESIA DURING WHOLE-BODY HYPERTHERMIA
    EISLER, K
    HIPP, R
    IPPISCH, A
    LANGE, J
    ZANKER, K
    STRAHLENTHERAPIE, 1985, 161 (09) : 531 - 532
  • [50] PRESSURE CORRECTION IN VOLUME AND FLOW-DISPLACEMENT BODY PLETHYSMOGRAPHY
    CLEMENT, J
    VANDEWOE.KP
    JOURNAL OF APPLIED PHYSIOLOGY, 1969, 27 (06) : 895 - &