Cochlear Implant Electrode Array Exposure: A Delayed Complication

被引:6
|
作者
Mishu, Christina [1 ,2 ]
Klodd, David A. [2 ]
Redleaf, Miriam [2 ]
机构
[1] Rush Univ, Med Ctr, Dept Commun Disorders & Sci, Chicago, IL 60612 USA
[2] Univ Illinois Hosp & Hlth Sci Syst, Dept Otolaryngol, 1855 W Taylor St,3rd Fl, Chicago, IL 60612 USA
关键词
D O I
10.1177/014556131709600708
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Exposure of the cochlear implant electrode array as a late complication has been reported rarely in the literature. A retrospective analysis revealed 4 patients presenting with exposure of their cochlear implant electrode arrays from 2 to 17 years after implantation. Data collected from these 4 patients were surgical implantation approach, type of implant, age at implant, interval between implant and complication, surgical correction of the problem, pathology at the time of correction, and length of follow-up after intervention. All 4 patients presented with otitis or mastoiditis. Each had undergone a transmastoid approach with facial recess and cochleostomy and full implant insertion. In 3 cases, the tympanic membrane had retracted to expose the electrode array. In 1 patient, the electrode array had eroded through the external canal, lateral to the facial recess. The exposed arrays were addressed surgically, including explantation/reimplantation for 1 patient. Cochlear implant electrode arrays can become exposed by relative migration of the array and the tympanic membrane. Implant surgeons and audiologists need to be aware of the possibility of this complication. Closure of the ear canal appears to be the most effective surgical intervention.
引用
收藏
页码:E40 / E43
页数:4
相关论文
共 50 条
  • [31] Shape optimization of cochlear implant electrode array using genetic algorithms
    Choi, CTM
    PROCEEDINGS OF THE 23RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: BUILDING NEW BRIDGES AT THE FRONTIERS OF ENGINEERING AND MEDICINE, 2001, 23 : 1445 - 1448
  • [32] The Impact of a Cochlear Implant Electrode Array on the Middle Ear Transfer Function
    Pazen, David
    Anagiotos, Andreas
    Nuenning, Maike
    Gostian, Antoniu-Oreste
    Ortmann, Magdalene
    Beutner, Dirk
    EAR AND HEARING, 2017, 38 (04): : E241 - E255
  • [33] Influence of the Cochlear Implant Electrode Array Placement on the Current Spread in the Cochlea
    Schaefer, Friederike
    Enke, Joerg
    Boehnke, Frank
    Hemmert, Werner
    Bai, Siwei
    2018 40TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2018, : 6145 - 6148
  • [34] Nanostructuring of cochlear implant electrode contacts induces delayed impedance increase in vivo
    Linke, Ines
    Fadeeva, Elena
    Scheper, Verena
    Esser, Karl-Heinz
    Koch, Juergen
    Chichkov, Boris N.
    Lenarz, Thomas
    Paasche, Gerrit
    PHYSICA STATUS SOLIDI A-APPLICATIONS AND MATERIALS SCIENCE, 2015, 212 (06): : 1210 - 1215
  • [35] Electrode array misplacement into the superior semicircular canal: As a rare complication of cochlear implantation
    Sun, Jia-Qiang
    Sun, Jing-Wu
    Hou, Xiao-Yan
    Bie, Yuan-Zhi
    Chen, Jian-Wen
    INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2014, 78 (09) : 1537 - 1540
  • [36] Design of a Cochlear Implant Electrode
    Dhanasingh, Anandhan
    ENT UPDATES, 2022, 12 (02): : 97 - 109
  • [37] MULTIPLE ELECTRODE COCHLEAR IMPLANT
    CLARK, GM
    TONG, YC
    BLACK, R
    FORSTER, IC
    PATRICK, JF
    DEWHURST, DJ
    JOURNAL OF LARYNGOLOGY AND OTOLOGY, 1977, 91 (11): : 935 - 945
  • [38] Pneumolabyrinth: An atypical complication in a cochlear implant
    Venegas, M. del Prado
    de Juan, Julia
    Orus, Cesar
    de Juan, Manuel
    ACTA OTORRINOLARINGOLOGICA ESPANOLA, 2016, 67 (02): : 114 - 116
  • [39] A Rare Case of Cochlear Implant Electrode Array Misplacement Into the Posterior Semicircular Canal
    Zhao, Christopher H.
    Quimby, Alexandra E.
    Bigelow, Douglas C.
    LARYNGOSCOPE, 2023, 133 (01): : 175 - 177
  • [40] Investigating variability in cochlear implant electrode array alignment and the potential of visualization guidance
    Yasin, Rashid
    Dedmon, Matthew
    Dillon, Neal
    Simaan, Nabil
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2019, 15 (06):