Cochlear Implant Electrode Array Exposure: A Delayed Complication

被引:6
|
作者
Mishu, Christina [1 ,2 ]
Klodd, David A. [2 ]
Redleaf, Miriam [2 ]
机构
[1] Rush Univ, Med Ctr, Dept Commun Disorders & Sci, Chicago, IL 60612 USA
[2] Univ Illinois Hosp & Hlth Sci Syst, Dept Otolaryngol, 1855 W Taylor St,3rd Fl, Chicago, IL 60612 USA
关键词
D O I
10.1177/014556131709600708
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Exposure of the cochlear implant electrode array as a late complication has been reported rarely in the literature. A retrospective analysis revealed 4 patients presenting with exposure of their cochlear implant electrode arrays from 2 to 17 years after implantation. Data collected from these 4 patients were surgical implantation approach, type of implant, age at implant, interval between implant and complication, surgical correction of the problem, pathology at the time of correction, and length of follow-up after intervention. All 4 patients presented with otitis or mastoiditis. Each had undergone a transmastoid approach with facial recess and cochleostomy and full implant insertion. In 3 cases, the tympanic membrane had retracted to expose the electrode array. In 1 patient, the electrode array had eroded through the external canal, lateral to the facial recess. The exposed arrays were addressed surgically, including explantation/reimplantation for 1 patient. Cochlear implant electrode arrays can become exposed by relative migration of the array and the tympanic membrane. Implant surgeons and audiologists need to be aware of the possibility of this complication. Closure of the ear canal appears to be the most effective surgical intervention.
引用
收藏
页码:E40 / E43
页数:4
相关论文
共 50 条
  • [11] Fixation of the electrode array with bone pate in cochlear implant surgery
    Gstoettner, WK
    Hamzavi, J
    Baumgartner, WD
    Czerny, CC
    ACTA OTO-LARYNGOLOGICA, 2000, 120 (03) : 369 - 374
  • [12] The rationale for FLEX (cochlear implant) electrode with varying array lengths
    Dhanasingh, Anandhan
    WORLD JOURNAL OF OTORHINOLARYNGOLOGY-HEAD & NECK SURGERY, 2021, 7 (01): : 45 - 53
  • [13] Challenging aspects of contemporary cochlear implant electrode array design
    Pavel Mistrík
    Claude Jolly
    Daniel Sieber
    Ingeborg Hochmair
    世界耳鼻咽喉头颈外科杂志英文版, 2017, (04) : 192 - 199
  • [14] Modelling and Optimization of the Insertion of a Preformed Cochlear Implant Electrode Array
    Rau, Th S.
    Lenarz, Th
    Majdani, O.
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2014, 59 : S1080 - +
  • [15] Cochlear implant electrode array misplacement: a cautionary case report
    Muzzi, E.
    Boscolo-Rizzo, P.
    Santarelli, R.
    Beltrame, M. A.
    JOURNAL OF LARYNGOLOGY AND OTOLOGY, 2012, 128 (04): : 414 - 417
  • [16] Effect of age, electrode array, and time on cochlear implant impedances
    Velandia, Sandra
    Martinez, Diane
    Goncalves, Stefania
    Pena, Stefanie
    Bas, Esperanza
    Ein, Liliana
    Prentiss, Sandra
    Telischi, Fred
    Angeli, Simon
    Dinh, Christine T.
    COCHLEAR IMPLANTS INTERNATIONAL, 2020, 21 (06) : 344 - 352
  • [17] Challenging aspects of contemporary cochlear implant electrode array design
    Mistrík Pavel
    Jolly Claude
    Sieber Daniel
    Hochmair Ingeborg
    世界耳鼻咽喉头颈外科杂志(英文), 2017, 3 (04)
  • [18] Recent Advances in Cochlear Implant Electrode Array Design Parameters
    Ertas, Yavuz Nuri
    Ozpolat, Derya
    Karasu, Saime Nur
    Ashammakhi, Nureddin
    MICROMACHINES, 2022, 13 (07)
  • [19] Cochlear implant electrode array misplaced in Hyrtl's fissure
    Mouzali, Amina
    Ouennoughi, Kheiredidine
    Haraoubia, Mohamed-Salah
    Zemirli, Omar
    Triglia, Jean Michel
    INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2011, 75 (11) : 1459 - 1462
  • [20] Early Outcomes With a Slim, Modiolar Cochlear Implant Electrode Array
    McJunkin, Jonathan L.
    Durakovic, Nedim
    Herzog, Jacques
    Buchman, Craig A.
    OTOLOGY & NEUROTOLOGY, 2018, 39 (01) : E28 - E33