An uncommon cause of cemented unicompartmental knee arthroplasty failure: fracture of metallic components

被引:10
|
作者
Manzotti, Alfonso [1 ]
Chemello, Cesare [2 ]
Pullen, Chris [3 ]
Cerveri, Pietro [4 ]
Confalonieri, Norberto [1 ]
机构
[1] CTO Hosp, Orthoped Dept 1, I-20100 Milan, Italy
[2] Azienda Osped Padova, Clin Ortoped, I-35123 Padua, Italy
[3] Royal Melbourne Hosp, Dept Orthopaed, Parkville, Vic 3050, Australia
[4] Politecn Milan, Bioengn Dept, I-20100 Milan, Italy
关键词
Unicompartmental Knee Arthroplasty; Metallic component breakage; FEMORAL COMPONENT; OXFORD KNEE; REPLACEMENT; REVISION; PROSTHESIS; THICKNESS; ALIGNMENT; WEAR;
D O I
10.1007/s00167-012-2062-y
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Despite good overall clinical results, unicompartmental knee replacements (UKR) are not without their problems and failures have been reported. The most common causes of UKR failure are component loosening, poor patient selection, poor surgical technique, polyethylene wear and progression of arthritis in other compartments. The purpose of this study is to present a series of atraumatic fractures of metallic components in a UKR treated in a single orthopaedic centre. Since 1999, 121 failed unicompartmental knee arthroplasties have been referred to our centre. In six of these, atraumatic breakage of a metal component in the cemented UKR was seen and included in this study. Pre-operative alignment, BMI and implant longevity were documented. The femoral implant failed in 4 patients and the tibial implant in a further 2. All the femoral implant fractures occurred within 3 years of UKR surgery (mean: 22.2 months, SD: 10.6 months). Tibial implant breakage occurred at a mean of 8.5 years (SD: 2.4 months) following UKR. All patients were treated with conversion to a navigated total knee replacement. A primary total knee arthroplasty was used in all cases with one patient requiring a tibial component incorporating a wedge and stem following breakage of the original UKR tibial implant. Fracture of the metallic components is a potential cause of failure of unicompartmental knee arthroplasty. In our experience, the incidence of this complication was 4.9 % of all UKR failures. Patients with a BMI greater than 30 and a progressive deterioration in limb alignment were at greater risk. IV.
引用
收藏
页码:2518 / 2522
页数:5
相关论文
共 50 条
  • [41] Lateral unicompartmental knee arthroplasty (UKA) showed a lower risk of failure compared to medial unicompartmental knee arthroplasty in the Register of Prosthetic Orthopedic Implants (RIPO)
    Alesi, Domenico
    Bordini, Barbara
    Fratini, Stefano
    Ancarani, Cristina
    Agostinone, Piero
    Grassi, Alberto
    Muccioli, Giulio Maria Marcheggiani
    Viceconti, Marco
    Zaffagnini, Stefano
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2023, 143 (06) : 3363 - 3368
  • [42] A Case of Subchondral Insufficiency Fracture of the Knee at Lateral Femoral Condyle Treated With Unicompartmental Knee Arthroplasty
    Lo, Chun Hin
    Tang, Yan Ho Bruce
    ARTHROPLASTY TODAY, 2022, 16 : 15 - 20
  • [43] Lateral unicompartmental knee arthroplasty (UKA) showed a lower risk of failure compared to medial unicompartmental knee arthroplasty in the Register of Prosthetic Orthopedic Implants (RIPO)
    Domenico Alesi
    Barbara Bordini
    Stefano Fratini
    Cristina Ancarani
    Piero Agostinone
    Alberto Grassi
    Giulio Maria Marcheggiani Muccioli
    Marco Viceconti
    Stefano Zaffagnini
    Archives of Orthopaedic and Trauma Surgery, 2023, 143 : 3363 - 3368
  • [44] The importance of pulsed lavage on interface temperature and ligament tension force in cemented unicompartmental knee arthroplasty
    Clarius, M.
    Seeger, J. B.
    Jaeger, S.
    Mohr, G.
    Bitsch, R. G.
    CLINICAL BIOMECHANICS, 2012, 27 (04) : 372 - 376
  • [45] Handlungsalgorithmus: Fraktur nach HemischlittenMedical algorithm: fracture after unicompartmental knee arthroplasty
    Yves Gramlich
    Matthias Schnetz
    Johannes Beckmann
    Reinhard Hoffmann
    Knie Journal, 2024, 6 (1) : 42 - 44
  • [46] Atraumatic Fracture of Cemented Vanguard Total Knee Arthroplasty Femoral Component
    Vovos, Tyler J.
    Watters, Tyler S.
    Hughes, Erin M.
    McNabb, David C.
    ORTHOPEDICS, 2020, 43 (05) : E476 - E479
  • [47] RETRACTED: The Influence of Different UHMWPE Components for Unicompartmental Knee Arthroplasty (Retracted Article)
    Liu, Chien-Wei
    Lo, Chia-Chi
    Tsai, Gwo-Chung
    Wang, Ching-Sung
    Ho, Chao-Chung
    Yu, Chen-Tung
    2010 4TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING (ICBBE 2010), 2010,
  • [48] Revision total knee arthroplasty with cemented components and uncemented intramedullary stems
    Shannon, BD
    Klassen, JF
    Rand, JA
    Berry, DJ
    Trousdale, RT
    JOURNAL OF ARTHROPLASTY, 2003, 18 (07): : 27 - 32
  • [49] Rotational malalignment of the components may cause chronic pain or early failure in total knee arthroplasty
    Hofmann, S
    Romero, J
    Roth-Schiffl, E
    Albrecht, T
    ORTHOPADE, 2003, 32 (06): : 469 - +
  • [50] Dependence of knee range of motion on the alignment of femoral and tibial components after medial unicompartmental knee arthroplasty
    Hanada, Mitsuru
    Hotta, Kensuke
    Matsuyama, Yukihiro
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2021, 31 (02): : 291 - 298