An uncommon cause of cemented unicompartmental knee arthroplasty failure: fracture of metallic components

被引:10
|
作者
Manzotti, Alfonso [1 ]
Chemello, Cesare [2 ]
Pullen, Chris [3 ]
Cerveri, Pietro [4 ]
Confalonieri, Norberto [1 ]
机构
[1] CTO Hosp, Orthoped Dept 1, I-20100 Milan, Italy
[2] Azienda Osped Padova, Clin Ortoped, I-35123 Padua, Italy
[3] Royal Melbourne Hosp, Dept Orthopaed, Parkville, Vic 3050, Australia
[4] Politecn Milan, Bioengn Dept, I-20100 Milan, Italy
关键词
Unicompartmental Knee Arthroplasty; Metallic component breakage; FEMORAL COMPONENT; OXFORD KNEE; REPLACEMENT; REVISION; PROSTHESIS; THICKNESS; ALIGNMENT; WEAR;
D O I
10.1007/s00167-012-2062-y
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Despite good overall clinical results, unicompartmental knee replacements (UKR) are not without their problems and failures have been reported. The most common causes of UKR failure are component loosening, poor patient selection, poor surgical technique, polyethylene wear and progression of arthritis in other compartments. The purpose of this study is to present a series of atraumatic fractures of metallic components in a UKR treated in a single orthopaedic centre. Since 1999, 121 failed unicompartmental knee arthroplasties have been referred to our centre. In six of these, atraumatic breakage of a metal component in the cemented UKR was seen and included in this study. Pre-operative alignment, BMI and implant longevity were documented. The femoral implant failed in 4 patients and the tibial implant in a further 2. All the femoral implant fractures occurred within 3 years of UKR surgery (mean: 22.2 months, SD: 10.6 months). Tibial implant breakage occurred at a mean of 8.5 years (SD: 2.4 months) following UKR. All patients were treated with conversion to a navigated total knee replacement. A primary total knee arthroplasty was used in all cases with one patient requiring a tibial component incorporating a wedge and stem following breakage of the original UKR tibial implant. Fracture of the metallic components is a potential cause of failure of unicompartmental knee arthroplasty. In our experience, the incidence of this complication was 4.9 % of all UKR failures. Patients with a BMI greater than 30 and a progressive deterioration in limb alignment were at greater risk. IV.
引用
收藏
页码:2518 / 2522
页数:5
相关论文
共 50 条
  • [21] Factors related to stress fracture after unicompartmental knee arthroplasty
    Yokoyama, Masamichi
    Nakamura, Yasuhiro
    Egusa, Makoto
    Doi, Hideyuki
    Onishi, Toru
    Hirano, Koji
    Doi, Motoyuki
    ASIA-PACIFIC JOURNAL OF SPORT MEDICINE ARTHROSCOPY REHABILITATION AND TECHNOLOGY, 2019, 15 : 1 - 5
  • [22] Medial tibial plateau fracture complicating unicompartmental knee arthroplasty
    Rudol, Grzegorz
    Jackson, Mark P.
    James, Stephen E.
    JOURNAL OF ARTHROPLASTY, 2007, 22 (01): : 148 - 150
  • [23] All-Polyethylene Tibial Components for Unicompartmental Knee Arthroplasty
    Plate, Johannes F.
    Augart, Marco A.
    Bracey, Daniel N.
    Jinnah, Alex
    Jinnah, Riyaz H.
    Poehling, Gary G.
    OPERATIVE TECHNIQUES IN ORTHOPAEDICS, 2015, 25 (02) : 114 - 119
  • [24] Hybrid Oxford unicompartmental knee arthroplasty has lower residual cement extrusion than cemented arthroplasty in treating end-stage unicompartmental knee osteoarthritis
    Guangzhong Yang
    Xufeng Jiao
    Qianli Li
    Zheng Li
    Shuai An
    Mingli Feng
    Guanghan Gao
    Jiang Huang
    Guanglei Cao
    BMC Musculoskeletal Disorders, 22
  • [25] Hybrid Oxford unicompartmental knee arthroplasty has lower residual cement extrusion than cemented arthroplasty in treating end-stage unicompartmental knee osteoarthritis
    Yang, Guangzhong
    Jiao, Xufeng
    Li, Qianli
    Li, Zheng
    An, Shuai
    Feng, Mingli
    Gao, Guanghan
    Huang, Jiang
    Cao, Guanglei
    BMC MUSCULOSKELETAL DISORDERS, 2021, 22 (01)
  • [26] The influence of the twin peg design on femoral Interface temperature and maximum load to failure in cemented Oxford unicompartmental knee arthroplasty
    Reiner, Tobias
    Schwarze, Martin
    Panzram, Benjamin
    Klotz, Matthias C.
    Bitsch, Rudi G.
    Jaeger, Sebastian
    CLINICAL BIOMECHANICS, 2018, 55 : 23 - 27
  • [27] Update on unicompartmental knee arthroplasty: Current indications and failure modes
    Vasso, Michele
    Antoniadis, Alexander
    Helmy, Naeder
    EFORT OPEN REVIEWS, 2018, 3 (08): : 442 - 448
  • [28] Use of All-polyethylene Tibial Components in Unicompartmental Knee Arthroplasty Increases the Risk of Early Failure
    Koh, In Jun
    Suhl, Kyung Hwan
    Kim, Min Woo
    Kim, Man Soo
    Choi, Keun Young
    In, Yong
    JOURNAL OF KNEE SURGERY, 2017, 30 (08) : 807 - 815
  • [29] Prior Knee Arthroscopy Increases the Failure Rate of Subsequent Unicompartmental Knee Arthroplasty
    Fassihi, Safa C.
    Gu, Alex
    Wessel, Lauren E.
    Thakkar, Savyasachi C.
    Sculco, Peter K.
    Ast, Michael P.
    JOURNAL OF ARTHROPLASTY, 2021, 36 (05): : 1556 - +
  • [30] Regional Femoral and Tibial Radiolucency in Cemented Unicompartmental Knee Arthroplasty and the Relationship to Functional Outcomes
    Kleeblad, Laura J.
    van der List, Jelle P.
    Zuiderbaan, Hendrik A.
    Pearle, Andrew D.
    JOURNAL OF ARTHROPLASTY, 2017, 32 (11): : 3345 - 3351