Design and Performance Investigation of a Multi-pinhole Collimator for a Small Field of View Gamma Imaging System

被引:3
|
作者
Bae, Jaekeon [1 ,2 ]
Bae, Seungbin [1 ,2 ]
Lee, Kisung [1 ,2 ]
Choi, Yong [3 ]
Kim, Yongkwon [4 ]
Joung, Jinhun [4 ]
机构
[1] Korea Univ, Dept Bioconvergence Engn, Seoul 136701, South Korea
[2] Korea Univ, Dept Med Devices, Guro Hosp, Seoul 152703, South Korea
[3] Sogang Univ, Dept Elect Engn, Seoul 121742, South Korea
[4] NuCare Med Syst Inc, Inchon 406840, South Korea
基金
新加坡国家研究基金会;
关键词
Limited angle system; Nuclear medicine; Multi-pinhole collimator;
D O I
10.3938/jkps.64.970
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
The aim of this study is to design a collimator for a gamma imaging system that has a smallfootprint, a fast-scan-time, and a organ-specific applicability. To achieve such features, the collimator must have a high resolution, a high sensitivity, and a gantry with a simple geometry. For ensuring high resolution and high sensitivity, we designed a multi-pinhole collimator. For realizing a simplified gantry, we carried out studies with limited angle reconstruction. On the designed multi-pinhole collimator has eight-pinholes, whose diameters are 2 mm. Limited-angle reconstruction has been conducted with angle intervals of 3, 6, 9, and 12 degrees and with an angle coverage of 60, 90, 120, 150, and 180 degrees. The reconstruction of an image was separately developed based on the ray-driven and voxel-driven methods in order to overcome the sampling problem and to reduce the amount of computation required. To evaluate the performance of the designed system, performed studies on three spherical phantoms and a heart phantom by using the Geant4 application for tomographic emission (GATE) simulation tool. The results showed that the full width at half maximum (FWHM) of the center source were 6.25 mm and 7.18 mm for single-pinhole and multi-pinhole collimators, respectively. Moreover, limited angle reconstruction resulted in a higher efficiency of the imaging system because it overcame the limitation of the gantry geometry. Limited-angle reconstruction was optimized at an angle coverage of 120. with an angle interval of 6 degrees, then reconstructed image was shown a 12.18 mm FWHM. This suggests that the designed system needs only one-third the number of projections to acquire a reconstructed image with a slight degradation in image quality. This also suggests that our proposed multi-pinhole collimator is suitable for applications requiring a small-footprint, a fast-scan-time, and organ-specificity.
引用
收藏
页码:970 / 975
页数:6
相关论文
共 50 条
  • [21] Monte-Carlo simulation of pinhole collimator of a small field of view gamma camera for small animal imaging
    Zhu Jie
    Ma Wenyan
    Zhu Yufeng
    Ma Hongguang
    Wu Yuelei
    Hu Huasi
    Zhang Boping
    Huo Yonggang
    Liu Silu
    Han Bin
    Wang Zhaomin
    NUCLEAR SCIENCE AND TECHNIQUES, 2009, 20 (01) : 37 - 41
  • [22] Spectral Multiplexing Multi-Pinhole Collimator Design forHigh Sensitivity Small Animal SPECT
    Wang, Wenying
    Feng, Tao
    JOURNAL OF NUCLEAR MEDICINE, 2021, 62
  • [23] Gamma Camera Imaging with Rotating Multi-Pinhole Collimator. A Monte Carlo Feasibility Study
    Ilisie, Victor
    Moliner, Laura
    Morera, Constantino
    Nuyts, Johan
    Benlloch, Jose Maria
    SENSORS, 2021, 21 (10)
  • [24] Small animal imaging with multi-pinhole SPECT
    Nuyts, Johan
    Vunckx, Kathleen
    Defrise, Michel
    Vanhove, Christian
    METHODS, 2009, 48 (02) : 83 - 91
  • [25] A Dual-head Multi-pinhole Collimator Design for Stationary Clinical Myocardial Perfusion Imaging
    Yan, Pengyu
    Mok, Greta S. P.
    Si, Chin-Hong
    Tsui, Benjamin M. W.
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [26] Design of a Multi-Pinhole Collimator in a Dual-Headed, Stationary, Small-Animal SPECT
    Shokouhi, S.
    Fritz, M. A.
    McDonald, B. S.
    Wilson, D. W.
    Metzler, S. D.
    Peterson, T. E.
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 2399 - 2402
  • [27] Gamma Source Location Learning from Synthetic Multi-pinhole Collimator Data
    von Niederhausern, Peter A.
    Seppi, Carlo
    Pezold, Simon
    Nicolas, Guillaume
    Gkoumas, Spyridon
    Haerle, Stephan K.
    Cattin, Philippe C.
    MACHINE LEARNING FOR MEDICAL IMAGE RECONSTRUCTION, MLMIR 2019, 2019, 11905 : 205 - 214
  • [28] Multi-pinhole collimator design in different numbers of projections for brain SPECT
    Huang, Wenbo
    Mok, Greta S. P.
    FRONTIERS IN MEDICINE, 2023, 10
  • [29] Design of rotating multi-pinhole SPECT system for high resolution small animal imaging.
    Ivanovic, M
    Weber, DA
    Loncaric, S
    JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (05) : 174P - 174P
  • [30] Performance Evaluation of a Novel Multi-Pinhole Collimator for Dopamine Transporter SPECT
    Tecklenburg, K.
    Apostolova, I.
    Klutmann, S.
    Buchert, R.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2019, 46 (SUPPL 1) : S275 - S275