A Dual-head Multi-pinhole Collimator Design for Stationary Clinical Myocardial Perfusion Imaging

被引:0
|
作者
Yan, Pengyu [1 ]
Mok, Greta S. P. [1 ]
Si, Chin-Hong [1 ]
Tsui, Benjamin M. W. [2 ]
机构
[1] Univ Macau, Fac Sci & Technol, Dept Elect & Comp Engn, Macau, Peoples R China
[2] Johns Hopkins Univ, Dept Radiol, Baltimore, MD 21201 USA
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Previously we designed a dual-purpose multi-pinhole (MPH) collimator for improved clinical myocardial perfusion imaging (MPI) with extra capability of small animal imaging for a clinical gamma camera. However, the standard configuration for current clinical MPI is L-mode with two detectors similar to 90 degrees apart. This study aims to design a dual-head L-mode MPH collimator for potential stationary MPI based on a clinical SPECT/CT scanner. Two stationary L-mode configurations, L-mode-I/II, were proposed based on the work of Rittenbach et al. where the long axis of the left ventricle was perpendicular to either camera. With the pre-defined pinhole pattern with minimal projection truncation and <20% multiplexing, maximum packing density and detector usage, the optimized MPH collimator parameters including pinhole number, radius-of-rotation, collimator length, aperture size and acceptance angle were determined by maximizing the sensitivity based on the pre-determined field-of-view of 20 cm and target resolution of 1 cm, considering the physical constraints of L-mode-I/II. Analytical simulations using the 4D extended cardiac-torso phantom (XCAT) were performed for 4 selected MPH designs with superior sensitivity results. Noise-free and noisy projections were generated and reconstructed using 3D MPH OS-EM algorithm. Reconstructed images were evaluated by visual assessment, normalized-mean-square-error (NMSE) and normalized standard deviation (NSD). L-mode-II generally showed less NMSE as compared to L-mode-I. For L-mode-I, 11-pinhole had the best NMSE-NSD trade-off while for L-mode-II, 18-pinhole had the best trade-off. We concluded that stationary MPI acquisition by using a dual-head MPH collimator is feasible and has the potential for dynamic MPI.
引用
收藏
页数:3
相关论文
共 50 条
  • [1] Evaluation of Stationary and Semi-stationary Acquisitions from Dual-head Multi-pinhole Collimator for Myocardial Perfusion SPECT
    Yan, Pengyu
    Chen, Ling
    Tsui, Benjamin M. W.
    Mok, Greta S. P.
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2016, 36 (05) : 675 - 685
  • [2] Evaluation of Stationary and Semi-stationary Acquisitions from Dual-head Multi-pinhole Collimator for Myocardial Perfusion SPECT
    Pengyu Yan
    Ling Chen
    Benjamin M. W. Tsui
    Greta S. P. Mok
    Journal of Medical and Biological Engineering, 2016, 36 : 675 - 685
  • [3] Evaluation of Stationary and Semi-stationary Acquisitions in a Dual-head Multi-pinhole System for Myocardial Perfusion SPECT
    Yan, Pengyu
    Mok, Greta S. P.
    Chen, Ling
    Tsui, Benjamin M. W.
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [4] Design of a dual-head multi-pinhole collimator for brain SPECT with improved axial sampling
    Konik, Arda
    Kalluri, Kesava
    Chen, Ling
    Mok, Greta
    Fromme, Timothy
    Zubal, George
    Furenlid, Lars
    King, Michael
    JOURNAL OF NUCLEAR MEDICINE, 2018, 59
  • [5] Design of an Optimized Multi-Pinhole Collimator for Dual-purpose Clinical and Preclinical Imaging
    Si, Chin-Hong
    Mok, Greta S. P.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 3189 - 3191
  • [6] Feasibility Studies of a High Sensitivity, Stationary Dedicated Cardiac SPECT with Multi-Pinhole Collimators on a Clinical Dual-Head Scanner
    Liu, Hui
    Wang, Shi
    Ma, Tianyu
    Wu, Jing
    Chen, Si
    Wei, Qingyang
    Dai, Tiantian
    Liu, Yaqiang
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [7] Design of a multi-pinhole collimator for high performance clinical and preclinical molecular imaging
    Mok, Greta
    Tsui, Benjamin
    Wang, Yi-Xiang
    Choi, Frankie
    Yip, Gabriel
    Ahuja, Anil
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51
  • [8] Design of a Multi-Pinhole Collimator in a Dual-Headed, Stationary, Small-Animal SPECT
    Shokouhi, S.
    Fritz, M. A.
    McDonald, B. S.
    Wilson, D. W.
    Metzler, S. D.
    Peterson, T. E.
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 2399 - 2402
  • [9] DEVELOPMENT OF A MULTI-PINHOLE COLLIMATOR FOR TOMOGRAPHIC RADIONUCLIDE IMAGING
    WILSON, BC
    ARNOLD, JE
    AUSTRALIAN AND NEW ZEALAND JOURNAL OF MEDICINE, 1981, 11 (04): : 440 - 440
  • [10] Design of an Optimized Multi-pinhole Collimator for Brain SPECT
    Chen, L.
    Mok, G. S.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 : S212 - S212