New Methods for Monitoring Neutral Grounding Resistors

被引:0
|
作者
Jafari, Rahim [1 ]
Kanabar, Mital [2 ]
Voloh, Ilia [2 ]
Sidhu, Tarlochan S. [3 ]
机构
[1] Western Univ, London, ON, Canada
[2] GE Grid Solut, Atlanta, GA USA
[3] Univ Ontario Inst Technol, Fac Engn & Appl Sci, Oshawa, ON, Canada
来源
2018 71ST ANNUAL CONFERENCE FOR PROTECTIVE RELAY ENGINEERS (CPRE) | 2018年
关键词
Neutral Grounding Resistor; Unit-Connected Generator; Signal Injection;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Electrical power systems control arcing current and electrical shock hazard by proper neutral grounding such as high resistance grounding. The high resistance neutral grounding resistors fail due to vibration, intermittent arcs, corrosion, etc. and cause the risk of the system being ungrounded, or solidly grounded. In this paper, two efficient solutions are introduced that provide continuous monitoring of such resistors installed at neutral of two most common configurations of the unit-connected generators. The first proposed method relies on the third harmonic of neutral and residual voltages, and the second technique employs the sub-harmonic injection based generator stator ground protection. The proposed methods show satisfying performance under different conditions of the resistor and generator, observed through comprehensive software analysis and further hardware validations. The first proposed monitoring method has been retrofitted to an industrial generator protection relay which no longer maloperates due to failed-short neutral grounding resistor. Proposed techniques can be incorporated into digital protective relays, which will monitor and alarm in case of the failed grounding resistor.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] NEUTRAL GROUNDING OF UTILITY TURBO-GENERATOR.
    Murthy, C.R.
    Tripathi, P.C.
    Raja Rao, A.
    Journal of the Institution of Engineers (India): Electrical Engineering Division, 1987, 67 : 148 - 151
  • [32] The Behaviour of Grounding in case of Neutral Wire Damage
    Kizhlo, Marina
    Kanbergs, Arvids
    2018 INTERNATIONAL SYMPOSIUM ON POWER ELECTRONICS, ELECTRICAL DRIVES, AUTOMATION AND MOTION (SPEEDAM), 2018, : 1014 - 1018
  • [33] A possible mechanism for neutral grounding resistor failures
    Labos, W
    Mannarino, A
    Drobnjak, G
    Ihara, S
    Skliutas, J
    2005 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS, 1-3, 2005, : 1149 - 1154
  • [34] About duration operate of resistor for neutral grounding
    Wishtibeev, AV
    KORUS 2003: 7TH KOREA-RUSSIA INTERNATIONAL SYMPOSIUM ON SCIENCE AND TECHNOLOGY, VOL 2, PROCEEDINGS: ELECTRICAL ENGINEERING AND INFORMATION TECHNOLOGY, 2003, : 282 - 286
  • [35] ANALYSIS OF METHODS FOR MONITORING OF EXISTING ENERGY OBJECTS GROUNDING DEVICES STATE AT THE PRESENT STAGE
    Koliushko, D. G.
    Rudenko, S. S.
    ELECTRICAL ENGINEERING & ELECTROMECHANICS, 2019, (01) : 67 - 72
  • [36] Zero-sequence voltages in unit-connected generator for different methods of grounding generator neutral
    Fulczyk, M
    SEVENTH INTERNATIONAL CONFERENCE ON DEVELOPMENTS IN POWER SYSTEM PROTECTION, 2001, (479): : 499 - 502
  • [37] NEW METHODS FOR MONITORING RETENTION
    BRITT, KW
    UNBEHEND, JE
    TAPPI, 1976, 59 (02): : 67 - 70
  • [38] Effect of Substation Grounding on the Neutral Voltage in Substations with Multiple Independent Resonant Grounding Systems
    Gargoom, Ameen
    Oo, Amanullah
    Haque, Md Enamul
    Cavanauh, Martin
    Bernardo, Jon
    2018 IEEE INDUSTRY APPLICATIONS SOCIETY ANNUAL MEETING (IAS), 2018,
  • [39] Earthing - Grounding methods: A primer
    Zipse, DW
    2002 IEEE INDUSTRIAL AND COMMERCIAL POWER SYSTEMS TECHNICAL CONFERENCE, CONFERENCE RECORD, 2002, : 158 - 177
  • [40] Earthing - Grounding methods: A primer
    Zipse, DW
    INDUSTRY APPLICATIONS SOCIETY 48TH ANNUAL PETROLEUM AND CHEMICAL INDUSTRY CONFERENCE, 2001, : 11 - 30