New Methods for Monitoring Neutral Grounding Resistors

被引:0
|
作者
Jafari, Rahim [1 ]
Kanabar, Mital [2 ]
Voloh, Ilia [2 ]
Sidhu, Tarlochan S. [3 ]
机构
[1] Western Univ, London, ON, Canada
[2] GE Grid Solut, Atlanta, GA USA
[3] Univ Ontario Inst Technol, Fac Engn & Appl Sci, Oshawa, ON, Canada
来源
2018 71ST ANNUAL CONFERENCE FOR PROTECTIVE RELAY ENGINEERS (CPRE) | 2018年
关键词
Neutral Grounding Resistor; Unit-Connected Generator; Signal Injection;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Electrical power systems control arcing current and electrical shock hazard by proper neutral grounding such as high resistance grounding. The high resistance neutral grounding resistors fail due to vibration, intermittent arcs, corrosion, etc. and cause the risk of the system being ungrounded, or solidly grounded. In this paper, two efficient solutions are introduced that provide continuous monitoring of such resistors installed at neutral of two most common configurations of the unit-connected generators. The first proposed method relies on the third harmonic of neutral and residual voltages, and the second technique employs the sub-harmonic injection based generator stator ground protection. The proposed methods show satisfying performance under different conditions of the resistor and generator, observed through comprehensive software analysis and further hardware validations. The first proposed monitoring method has been retrofitted to an industrial generator protection relay which no longer maloperates due to failed-short neutral grounding resistor. Proposed techniques can be incorporated into digital protective relays, which will monitor and alarm in case of the failed grounding resistor.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] DRYER GROUNDING AND NEUTRAL CONDUCTORS
    SANDERS, MK
    EC&M-ELECTRICAL CONSTRUCTION AND MAINTENANCE, 1984, 83 (05): : 128 - 128
  • [22] Online neutral grounding resistor monitoring for unit-connected generators with hardware validation
    Jafari, R.
    Kanabar, M.
    Sidhu, T. S.
    Voloh, I.
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2019, 105 : 220 - 228
  • [23] Simulation of single-phase grounding fault on non-grounding neutral power system and new conclusions
    Southwest Jiaotong University, Chengdu 610031, China
    Dianli Zidonghua Shebei Electr. Power Autom. Equip., 2006, 2 (33-36):
  • [24] EXPERIENCE OF NEW-ENGLAND SYSTEM WITH GENERATOR PROTECTION BY RESONANT NEUTRAL GROUNDING
    GROSS, ETB
    GULACHENSKI, EM
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1973, PA92 (04): : 1186 - 1194
  • [25] Effects of Neutral Point Grounding Methods on Single-Phase Short Circuit Fault Characteristics
    Kokor, Amela
    Smaka, Senad
    Grebovic, Selma
    Helac, Vahid
    2022 21ST INTERNATIONAL SYMPOSIUM INFOTEH-JAHORINA (INFOTEH), 2022,
  • [26] Insulation Monitoring on Common Grounding Methods: Its Use in the Pulp and Paper Industry
    Magenes, Luca
    Dinh, Hao Q.
    Klein, Andrew
    IEEE INDUSTRY APPLICATIONS MAGAZINE, 2020, 26 (01) : 21 - 28
  • [27] PRACTICAL GROUNDING METHODS
    不详
    ANESTHESIOLOGY, 1956, 17 (04) : 621 - 623
  • [28] A new approach to fault-line selection of small current neutral grounding system
    Chen, Yujie
    Chen, Huiwei
    Song, Baoye
    Liu, Yanni
    Liu, Peixue
    SYSTEMS SCIENCE & CONTROL ENGINEERING, 2018, 6 (03): : 28 - 34
  • [29] A new approach floor monitoring grounding grid of electrical power system
    Liu Cong-li
    Peng Minfang
    ICEMI 2007: PROCEEDINGS OF 2007 8TH INTERNATIONAL CONFERENCE ON ELECTRONIC MEASUREMENT & INSTRUMENTS, VOL IV, 2007, : 419 - 422
  • [30] Typical neutral grounding schemes for paper mills
    Rau, JR
    Meister, MA
    CONFERENCE RECORD OF 1998 ANNUAL PULP AND PAPER INDUSTRY TECHNICAL CONFERENCE, 1998, : 16 - 20