Comparison of Augmentation Methods for Internal Fixation of Osteoporotic Ankle Fractures

被引:32
|
作者
Panchbhavi, Vinod K. [1 ]
Vallurupalli, Santaram [1 ]
Morris, Randal [1 ]
机构
[1] Univ Texas Med Branch, Dept Orthopaed Surg & Rehabil, Galveston, TX 77555 USA
关键词
Internal Fixation; Osteoporotic Ankle Fractures; Ankle Fixation; MTS Machine; Lateral Fibular Plate; Supination External Rotation Injury; CALCIUM-PHOSPHATE CEMENT; BIOMECHANICAL EVALUATION; ELDERLY-PATIENTS; BONE; AGE;
D O I
10.3113/FAI.2009.0696
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Internal fixation of osteoporotic ankle fractures is associated with failure of fixation. This study compared different augmentation methods biomechanically. Materials and Methods: In nine paired fresh-frozen cadaver legs, an identical supination-external rotation type II ankle fracture was created. Fractures were stabilized using an eight-hole locking plate. In four pairs, two screws were inserted across the syndesmosis for purchase in the tibial metaphysis. One leg from each pair was randomly selected for injection of calcium sulphate-calcium phosphate graft into the screw holes. Each leg was mounted to an NITS machine in a custom loading frame. Axial cyclic loading to body weight was performed to measure displacement at the fracture site, followed by rotational loading to failure simulating a supination external rotation injury. Data were analyzed using a two-way paired t-test and ANOVA. Results: The specimens used had a mean bone mineral density of 0.49 +/- 0.15 (SD) g/cm(2), and a mean age of 83 +/- 12 years. In the biomechanical tests, there were no significant differences between augmented and non-augmented locking plates without the tibia-pro-fibula screws in axial stiffness (p = 0.10), external rotation angle at failure (p = 0.42), failure torque (p = 0.57), energy absorbed before failure (p = 0.47), and motion at the fracture site with cyclic axial loading (p = 0.15). There were no significant differences between augmented and non-augmented locking plates with the tibia-pro-fibula screws in the external rotation angle at failure (p = 0.83), failure torque (p = 0.58), and failure energy (p = 0.4). However, the overall strength of the fixation tended to increase with tibia-pro-fibula screws and augmentation. Conclusion: Internal fixation of an osteoporotic lateral malleolar fracture using a locking plate and screws provided a construct comparable in strength to that augmented with calcium sulfate-calcium phosphate graft and/or tibia-pro-fibula screws. Clinical Relevance: Strategies to augment internal fixation of osteoporotic ankle fractures may minimize risk for failure of fixation and may enable early weight bearing mobilization and return to function in elderly patients.
引用
收藏
页码:696 / 703
页数:8
相关论文
共 50 条
  • [41] Comparison of screw fixation and dynamic fixation in the treatment of ankle fractures with syndesmotic ruptures
    Gungor, Erdal
    Ercan, Niyazi
    Ovali, Sancar Alp
    Aydugan, Mehmet Yagiz
    Cetin, Hikmet
    ULUSAL TRAVMA VE ACIL CERRAHI DERGISI-TURKISH JOURNAL OF TRAUMA & EMERGENCY SURGERY, 2024, 30 (12): : 900 - 906
  • [42] Infected Internal Fixation after Ankle Fractures-A Treatment Path
    Kollrack, Yvonne Bernadette Maria
    Moellenhoff, Gunnar
    JOURNAL OF FOOT & ANKLE SURGERY, 2012, 51 (01): : 9 - 12
  • [43] BIMALLEOLAR AND TRIMALLEOLAR ANKLE FRACTURES OPERATED WITH NONRIGID INTERNAL-FIXATION
    OLERUD, C
    MOLANDER, H
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1986, (206) : 253 - 260
  • [44] OPEN REDUCTION AND INTERNAL SCREW FIXATION OF TRANSITIONAL ANKLE FRACTURES IN ADOLESCENTS
    Denning, Jaime R.
    Gohel, Shivani
    Arkader, Alexandre
    JBJS ESSENTIAL SURGICAL TECHNIQUES, 2021, 11 (04):
  • [45] Complication Rates Following Open Reduction and Internal Fixation of Ankle Fractures
    SooHoo, Nelson F.
    Krenek, Lucie
    Eagan, Michael J.
    Gurbani, Barkha
    Ko, Clifford Y.
    Zingmond, David S.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (05): : 1042 - 1049
  • [46] Optimizing stabilization in osteoporotic ankle fractures
    Chan, Jeremy Y.
    Bishop, Julius A.
    CURRENT ORTHOPAEDIC PRACTICE, 2015, 26 (06): : 605 - 609
  • [47] Ankle fractures in women and osteoporotic fracture?
    Nieto, E
    Salinas, JR
    Batalla, A
    Rivas, E
    Ferrer, L
    OSTEOPOROSIS INTERNATIONAL, 2004, 15 : S69 - S69
  • [48] In vitro biomechanical comparison of three methods for internal fixation of femoral neck fractures in dogs
    Fisher, S. C.
    McLaughlin, R. M.
    Elder, S. H.
    VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2012, 25 (01) : 36 - 41
  • [49] Stability of internal versus external fixation in osteoporotic pelvic fractures - a biomechanical analysis
    Hack, J.
    Kranz, Y.
    Knauf, T.
    Baeumlein, M.
    Malcherczyk, D.
    Ruchholtz, S.
    Oberkircher, L.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2020, 51 (11): : 2460 - 2464
  • [50] Cement augmentation for osteoporotic compression fractures
    Lee, M. J.
    Jarvik, J. G.
    UNFALLCHIRURG, 2012, 115 (12): : 1066 - 1069