Background: Internal fixation of osteoporotic ankle fractures is associated with failure of fixation. This study compared different augmentation methods biomechanically. Materials and Methods: In nine paired fresh-frozen cadaver legs, an identical supination-external rotation type II ankle fracture was created. Fractures were stabilized using an eight-hole locking plate. In four pairs, two screws were inserted across the syndesmosis for purchase in the tibial metaphysis. One leg from each pair was randomly selected for injection of calcium sulphate-calcium phosphate graft into the screw holes. Each leg was mounted to an NITS machine in a custom loading frame. Axial cyclic loading to body weight was performed to measure displacement at the fracture site, followed by rotational loading to failure simulating a supination external rotation injury. Data were analyzed using a two-way paired t-test and ANOVA. Results: The specimens used had a mean bone mineral density of 0.49 +/- 0.15 (SD) g/cm(2), and a mean age of 83 +/- 12 years. In the biomechanical tests, there were no significant differences between augmented and non-augmented locking plates without the tibia-pro-fibula screws in axial stiffness (p = 0.10), external rotation angle at failure (p = 0.42), failure torque (p = 0.57), energy absorbed before failure (p = 0.47), and motion at the fracture site with cyclic axial loading (p = 0.15). There were no significant differences between augmented and non-augmented locking plates with the tibia-pro-fibula screws in the external rotation angle at failure (p = 0.83), failure torque (p = 0.58), and failure energy (p = 0.4). However, the overall strength of the fixation tended to increase with tibia-pro-fibula screws and augmentation. Conclusion: Internal fixation of an osteoporotic lateral malleolar fracture using a locking plate and screws provided a construct comparable in strength to that augmented with calcium sulfate-calcium phosphate graft and/or tibia-pro-fibula screws. Clinical Relevance: Strategies to augment internal fixation of osteoporotic ankle fractures may minimize risk for failure of fixation and may enable early weight bearing mobilization and return to function in elderly patients.
引用
收藏
页码:696 / 703
页数:8
相关论文
共 50 条
  • [31] Operative management of lateral third clavicle fractures: a comparison of internal fixation methods
    Patrick Hickland
    Christopher Goodland
    Sunil Zachariah
    Lynn E Murphy
    Martyn Neil
    European Journal of Orthopaedic Surgery & Traumatology, 2023, 33 : 159 - 165
  • [32] Comparison of four different internal fixation methods in the treatment of distal clavicle fractures
    Li, Liang
    Wu, Hongxiao
    Jiang, Peichao
    Han, Xiaochuan
    Chen, Shiyuan
    Yu, Xuezhong
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2020, 19 (01) : 451 - 458
  • [33] Principles of fixation of osteoporotic fractures
    Giannoudis, P. V.
    Schneider, E.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2006, 88B (10): : 1272 - 1278
  • [34] Alternative Fixation in Osteoporotic Fractures
    Tafur D.
    Cabrera D.A.
    Salavarrieta J.
    Olarte C.M.
    Pesántez R.F.
    Current Geriatrics Reports, 2017, 6 (3) : 196 - 201
  • [35] A Biomechanical Comparison of Internal Fixation Techniques for Ankle Arthrodesis
    Clifford, Craig
    Berg, Scott
    McCann, Kevin
    Hutchinson, Byron
    JOURNAL OF FOOT & ANKLE SURGERY, 2015, 54 (02): : 188 - 191
  • [36] Salvage of osteoporotic ankle fractures after failed primary fixation with an ankle arthrodesis nail: A report on ifour cases
    Houshian, Shirzad
    Bajaj, Sunil K.
    Mohammed, Abdul Moqeeth
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2006, 37 (08): : 791 - 794
  • [37] Augmentation of Implant Fixation in Osteoporotic Bone
    Clifford B. Jones
    Current Osteoporosis Reports, 2012, 10 : 328 - 336
  • [38] Biomechanical evaluation of combined short segment fixation and augmentation of incomplete osteoporotic burst fractures
    René Hartensuer
    Dominic Gehweiler
    Martin Schulze
    Lars Matuszewski
    Michael J Raschke
    Thomas Vordemvenne
    BMC Musculoskeletal Disorders, 14
  • [39] Augmentation of Implant Fixation in Osteoporotic Bone
    Jones, Clifford B.
    CURRENT OSTEOPOROSIS REPORTS, 2012, 10 (04) : 328 - 336
  • [40] Biomechanical evaluation of combined short segment fixation and augmentation of incomplete osteoporotic burst fractures
    Hartensuer, Rene
    Gehweiler, Dominic
    Schulze, Martin
    Matuszewski, Lars
    Raschke, Michael J.
    Vordemvenne, Thomas
    BMC MUSCULOSKELETAL DISORDERS, 2013, 14