Assessment of Compatibility between Various Intraoral Scanners and 3D Printers through an Accuracy Analysis of 3D Printed Models

被引:13
|
作者
Im, Chang-Hee [1 ]
Park, Ji-Man [1 ]
Kim, Jang-Hyun [1 ]
Kang, You-Jung [1 ]
Kim, Jee-Hwan [1 ]
机构
[1] Yonsei Univ, Dept Prosthodont, Coll Dent, 50-1 Yonsei Ro, Seoul 03722, South Korea
关键词
dental computer aided manufacturing (CAD-CAM); intraoral scanner; 3-dimensional printer; quadrant model; trueness; IN-VIVO PRECISION; SCANNING SYSTEMS; DIGITAL METHODS; IMPRESSIONS; TRUENESS;
D O I
10.3390/ma13194419
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
To assess the accuracy of various intraoral scanners (IOSs) and to investigate the existence of mutual compatibility that affects the accuracy between IOS and 3-dimensional (3D) printing using a scan quadrant model. For clinical implication, crown preparations and cavity design according to prosthetic diagnosis and treatment considerations must be acquired by a digital scanner. The selected typodont model was scanned using a reference scanner, from which reference (Ref) standard tessellation language (STL) data were created. Data obtained by scanning the typodont model with IOSs based on three different technologies were divided into three groups (CS3600, i500, and Trios3). Scanned data from the groups were divided into sub-groups of digital light processing (DLP), fused deposition modeling (FDM), and stereolithography apparatus (SLA), based on which 3D printed models (3DP) were fabricated. The 3DP dental models were scanned to obtain a total of 90 3DP STL datasets. The best-fit algorithm of 3D analysis software was used for teeth and arch measurements, while trueness was analyzed by calculating the average deviation among measured values based on superimposition of Ref and IOS and 3DP data. The differences between Ref and IOS (Ref-IOS), Ref and 3DP (Ref-IOS/3DP), and IOS and 3DP data (IOS-3DP) were compared and analyzed, while accuracy within each of the three main groups was assessed. For statistical analysis, the Kruskal-Wallis, Mann-Whitney U, and repeated measures ANOVA test were used (p < 0.05). The major finding is that the mutual relationships between IOSs and 3D printers vary depending on the combination. However, i500 intraoral scanner and DLP 3D printer was the combination that showed the best trueness value.
引用
收藏
页码:1 / 16
页数:16
相关论文
共 50 条
  • [31] Accuracy of 3D surface scanners for clinical torso and spinal deformity assessment
    Grant, Caroline A.
    Johnston, Melissa
    Adam, Clayton J.
    Little, J. Paige
    MEDICAL ENGINEERING & PHYSICS, 2019, 63 : 63 - 71
  • [32] Security Analysis of Networked 3D Printers
    McCormack, Matthew
    Chandrasekaran, Sanjay
    Liu, Guyue
    Yu, Tianlong
    Wolf, Sandra DeVincent
    Sekar, Vyas
    2020 IEEE SYMPOSIUM ON SECURITY AND PRIVACY WORKSHOPS (SPW 2020), 2020, : 118 - 125
  • [33] Dimensional accuracy of 3D printed vertebra
    Ogden, Kent
    Ordway, Nathaniel
    Diallo, Dalanda
    Tillapaugh-Fay, Gwen
    Aslan, Can
    MEDICAL IMAGING 2014: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2014, 9036
  • [34] SoftPrint: Investigating Haptic Softness Perception of 3D Printed Soft Object in FDM 3D Printers
    Miyoshi, Motoki
    Punpongsanon, Parinya
    Iwai, Daisuke
    Sato, Kosuke
    JOURNAL OF IMAGING SCIENCE AND TECHNOLOGY, 2021, 65 (04)
  • [35] A 3D Printed Device for the Quality Assurance of 3D Printers Used for Bolus Fabrication in Radiation Therapy
    Lowe, Hunter
    Lawyer, Kim
    Maynard, Evan
    Chng, Nick
    Matthews, Quinn
    MEDICAL PHYSICS, 2024, 51 (08) : 5806 - 5806
  • [36] 3D Model Data Generation and Conversion for 3D Printers
    Kim, Sungsuk
    JOURNAL OF ELECTRONIC MATERIALS, 2015, 44 (03) : 815 - 822
  • [37] Measuring and Establishing the Accuracy and Reproducibility of 3D Printed Medical Models
    George, Elizabeth
    Liacouras, Peter
    Rybicki, Frank J.
    Mitsouras, Dimitrios
    RADIOGRAPHICS, 2017, 37 (05) : 1424 - 1450
  • [38] Quantification of the accuracy of additive manufactured (3D printed) medical models
    Manmadhachary, A.
    Siva Rama Krishana, L.
    Saxena, Kuldeep K.
    INTERNATIONAL JOURNAL OF INTERACTIVE DESIGN AND MANUFACTURING - IJIDEM, 2022,
  • [39] Investigating accuracy of 3D printed liver models with computed tomography
    Witowski, Jan
    Wake, Nicole
    Grochowska, Anna
    Sun, Zhonghua
    Budzynski, Andrzej
    Major, Piotr
    Popiela, Tadeusz Jan
    Pedziwiatr, Michal
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2019, 9 (01) : 43 - 52
  • [40] 3D Model Data Generation and Conversion for 3D Printers
    Sungsuk Kim