3D Late Gadolinium Enhancement in a Single Prolonged Breath-Hold using Supplemental Oxygenation and Hyperventilation

被引:12
|
作者
Roujol, Sebastien [1 ,2 ]
Basha, Tamer A. [1 ,2 ]
Akcakaya, Mehmet [1 ,2 ]
Foppa, Murilo [1 ,2 ]
Chan, Raymond H. [1 ,2 ]
Kissinger, Kraig V. [1 ,2 ]
Goddu, Beth [1 ,2 ]
Berg, Sophie [1 ,2 ]
Manning, Warren J. [1 ,2 ,3 ]
Nezafat, Reza [1 ,2 ]
机构
[1] Beth Israel Deaconess Med Ctr, Dept Med, Div Cardiovasc, Boston, MA 02215 USA
[2] Harvard Univ, Sch Med, Boston, MA USA
[3] Beth Israel Deaconess Med Ctr, Dept Radiol, Boston, MA 02215 USA
基金
美国国家卫生研究院;
关键词
late gadolinium enhancement; myocardial viability; 3D acquisition; acceleration techniques; breath-hold; left ventricle; hyperventilation; compressed sensing; SENSITIVE INVERSION-RECOVERY; CORONARY MR-ANGIOGRAPHY; MYOCARDIAL-INFARCTION; DELAYED HYPERENHANCEMENT; IMAGE-RECONSTRUCTION; ATRIAL-FIBRILLATION; SPATIAL-RESOLUTION; CARDIAC MR; VIABILITY; MOTION;
D O I
10.1002/mrm.24969
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the feasibility of three-dimensional (3D) single breath-hold late gadolinium enhancement (LGE) of the left ventricle (LV) using supplemental oxygen and hyperventilation and compressed-sensing acceleration. Methods: Breath-hold metrics [breath-hold duration, diaphragmatic/LV position drift, and maximum variation of R wave to R wave (RR) interval] without and with supplemental oxygen and hyperventilation were assessed in healthy adult subjects using a real-time single shot acquisition. Ten healthy subjects and 13 patients then underwent assessment of the proposed 3D breath-hold LGE acquisition (field of view = 320 x 320 x 100 mm(3), resolution = 1.6 x 1.6 x 5.0 mm(3), acceleration rate of 4) and a free-breathing acquisition with right hemidiaphragm navigator (NAV) respiratory gating. Semiquantitative grading of overall image quality, motion artifact, myocardial nulling, and diagnostic value was performed by consensus of two blinded observers. Results: Supplemental oxygenation and hyperventilation increased the breath-hold duration (35+/-11 s to 58+/-21 s; P< 0.0125) without significant impact on diaphragmatic/LV position drift or maximum variation of RR interval (both P> 0.01). LGE images were of similar quality when compared with free-breathing acquisitions, but with reduced total scan time (85+/-22 s to 35+/-6 s; P< 0.001). Conclusions: Supplemental oxygenation and hyperventilation allow for prolonged breath-holding and enable single breath-hold 3D accelerated LGE with similar image quality as free breathing with NAV. (C) 2013 Wiley Periodicals, Inc.
引用
收藏
页码:850 / 857
页数:8
相关论文
共 50 条
  • [41] Dynamic breath-hold 3D gadolinium-enhanced MRI of intraarterial masses: Findings in two patients (vol 21, pg 631, 1997)
    Krinsky, G
    Rofsky, N
    Sadler, M
    DeCorato, D
    Weinreb, J
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1997, 21 (06) : A5 - A5
  • [42] Magnetic resonance coronary angiography with 3D TrueFISP: breath-hold versus respiratory gated imaging
    So, NMC
    Lam, WWM
    Li, D
    Chan, AKY
    Sanderson, JE
    Metreweli, C
    BRITISH JOURNAL OF RADIOLOGY, 2005, 78 (926): : 116 - 121
  • [43] Fast 3D Imaging via Deep learning for Deep Inspiration Breath-hold Lung Radiotherapy
    Lei, Yang
    Tian, Zhen
    Wang, Tonghe
    Axente, Marian
    Roper, Justin
    Higgins, Kristin
    Bradley, Jeffrey D.
    Liu, Tian
    Yang, Xiaofeng
    MEDICAL IMAGING 2022: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2022, 12034
  • [44] Myocardial viability: Breath-hold 3D MR imaging of delayed hyperenhancement with variable sampling in time
    Foo, TKF
    Stanley, DW
    Castillo, E
    Rochitte, CE
    Wang, Y
    Lima, JAC
    Bluemke, DA
    Wu, KC
    RADIOLOGY, 2004, 230 (03) : 845 - 851
  • [45] Single breath-hold saturation recovery 3D cardiac T1 mapping via compressed SENSE at 3T
    Ferreira da Silva, Tiago
    Galan-Arriola, Carlos
    Montesinos, Paula
    Lopez-Martin, Gonzalo Javier
    Desco, Manuel
    Fuster, Valentin
    Ibanez, Borja
    Sanchez-Gonzalez, Javier
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2020, 33 (06) : 865 - 876
  • [46] Breath-hold 3D MRA of the abdominal aorta, renal and pelvic arteries compared to conventional arteriography
    Hany, TF
    Pfammatter, T
    McKinnon, GC
    Leung, DA
    Debatin, JF
    RADIOLOGY, 1997, 205 : 277 - 277
  • [47] Single breath-hold saturation recovery 3D cardiac T1 mapping via compressed SENSE at 3T
    Tiago Ferreira da Silva
    Carlos Galan-Arriola
    Paula Montesinos
    Gonzalo Javier López-Martín
    Manuel Desco
    Valentín Fuster
    Borja Ibáñez
    Javier Sanchez-Gonzalez
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2020, 33 : 865 - 876
  • [48] Single breath-hold 3D mapping of T1 and T2 relaxation times with 3D-QALAS - feasibility in patients
    Sofia Kvernby
    Marcel Warntjes
    Carl Johan Carlhall
    Jan E Engvall
    Tino Ebbers
    Journal of Cardiovascular Magnetic Resonance, 17 (Suppl 1)
  • [49] Comparison of Deep Inspiration Breath Hold Left Breast Tangents With Active Breath Hold and Voluntary Breath Hold Using 3D Surface Image Guidance
    Zhao, B.
    Rahimi, A. S.
    Yan, Y.
    Spangler, A.
    Jiang, S. B.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S840 - S840
  • [50] 3D Lung Tumor Position Verification During Breath-Hold Stereotactic Volumetric Modulated Arc Therapy
    Hazelaar, C.
    Dahele, M.
    Mostafavi, H.
    van der Weide, L.
    Keek, S.
    Slotman, B.
    Verbakel, W.
    MEDICAL PHYSICS, 2017, 44 (06) : 3224 - 3224