3D Late Gadolinium Enhancement in a Single Prolonged Breath-Hold using Supplemental Oxygenation and Hyperventilation

被引:12
|
作者
Roujol, Sebastien [1 ,2 ]
Basha, Tamer A. [1 ,2 ]
Akcakaya, Mehmet [1 ,2 ]
Foppa, Murilo [1 ,2 ]
Chan, Raymond H. [1 ,2 ]
Kissinger, Kraig V. [1 ,2 ]
Goddu, Beth [1 ,2 ]
Berg, Sophie [1 ,2 ]
Manning, Warren J. [1 ,2 ,3 ]
Nezafat, Reza [1 ,2 ]
机构
[1] Beth Israel Deaconess Med Ctr, Dept Med, Div Cardiovasc, Boston, MA 02215 USA
[2] Harvard Univ, Sch Med, Boston, MA USA
[3] Beth Israel Deaconess Med Ctr, Dept Radiol, Boston, MA 02215 USA
基金
美国国家卫生研究院;
关键词
late gadolinium enhancement; myocardial viability; 3D acquisition; acceleration techniques; breath-hold; left ventricle; hyperventilation; compressed sensing; SENSITIVE INVERSION-RECOVERY; CORONARY MR-ANGIOGRAPHY; MYOCARDIAL-INFARCTION; DELAYED HYPERENHANCEMENT; IMAGE-RECONSTRUCTION; ATRIAL-FIBRILLATION; SPATIAL-RESOLUTION; CARDIAC MR; VIABILITY; MOTION;
D O I
10.1002/mrm.24969
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the feasibility of three-dimensional (3D) single breath-hold late gadolinium enhancement (LGE) of the left ventricle (LV) using supplemental oxygen and hyperventilation and compressed-sensing acceleration. Methods: Breath-hold metrics [breath-hold duration, diaphragmatic/LV position drift, and maximum variation of R wave to R wave (RR) interval] without and with supplemental oxygen and hyperventilation were assessed in healthy adult subjects using a real-time single shot acquisition. Ten healthy subjects and 13 patients then underwent assessment of the proposed 3D breath-hold LGE acquisition (field of view = 320 x 320 x 100 mm(3), resolution = 1.6 x 1.6 x 5.0 mm(3), acceleration rate of 4) and a free-breathing acquisition with right hemidiaphragm navigator (NAV) respiratory gating. Semiquantitative grading of overall image quality, motion artifact, myocardial nulling, and diagnostic value was performed by consensus of two blinded observers. Results: Supplemental oxygenation and hyperventilation increased the breath-hold duration (35+/-11 s to 58+/-21 s; P< 0.0125) without significant impact on diaphragmatic/LV position drift or maximum variation of RR interval (both P> 0.01). LGE images were of similar quality when compared with free-breathing acquisitions, but with reduced total scan time (85+/-22 s to 35+/-6 s; P< 0.001). Conclusions: Supplemental oxygenation and hyperventilation allow for prolonged breath-holding and enable single breath-hold 3D accelerated LGE with similar image quality as free breathing with NAV. (C) 2013 Wiley Periodicals, Inc.
引用
收藏
页码:850 / 857
页数:8
相关论文
共 50 条
  • [31] 3D SINGLE BREATH-HOLD MRE FOR THE SIMULTANEOUS ASSESSMENT OF LIVER FIBROSIS AND INFLAMMATION IN PATIENTS WITH NAFLD/NASH.
    Darwish, Omar
    Neji, Radhouene
    Metwalli, Nader
    Feeley, Jenna
    Jeljeli, Sami
    Rotman, Yaron
    Brown, Rebecca
    Kleiner, David E.
    Sinkus, Ralph
    Gharib, Ahmed M.
    HEPATOLOGY, 2022, 76 : S852 - S852
  • [32] Breath-hold 3D dynamic single-dose gadolinium-enhanced MR angiography (MRA) versus 3D phase-contrast MR angiography in evaluation of renal artery stenosis
    DeCobelli, F
    Vanzulli, A
    Sironi, S
    Angeli, E
    Venturini, M
    DelMaschio, A
    RADIOLOGY, 1997, 205 : 272 - 272
  • [33] Optimization of contrast material administration for breath-hold 3D MR angiography of the abdominal vessels
    Kopka, L
    Vosshenrich, R
    Rodenwaldt, J
    Grabbe, EH
    RADIOLOGY, 1997, 205 : 673 - 673
  • [34] Comparison of 3D dense deformable registration methods for breath-hold reproducibility study in radiotherapy
    Boldea, Vlad
    Sarrut, David
    Carrie, Christian
    Progr. Biomed. Opt. Imaging Proc. SPIE, I (222-230):
  • [35] Comparison of 3D dense deformable registration methods for breath-hold reproducibility study in radiotherapy
    Boldea, V
    Sarrut, D
    Carrie, C
    Medical Imaging 2005: Image Processing, Pt 1-3, 2005, 5747 : 222 - 230
  • [36] Comparison of breath-hold 3D and retrospectively respiratory gated 3D MR coronary angiography with conventional coronary arteriography
    Wielopolski, PA
    VanGuens, RJ
    DeFeijter, PJ
    DeBruin, HG
    Bongaerts, AH
    Oudkerk, M
    RADIOLOGY, 1997, 205 : 59 - 59
  • [37] Rapid 3D breath-hold MR cholangiopancreatography using deep learning-constrained compressed sensing reconstruction
    Zhang, Yu
    Peng, Wanlin
    Xiao, Yi
    Ming, Yue
    Ma, Kehang
    Hu, Sixian
    Zeng, Wen
    Zeng, Lingming
    Liang, Zejun
    Zhang, Xiaoyong
    Xia, Chunchao
    Li, Zhenlin
    EUROPEAN RADIOLOGY, 2023, 33 (04) : 2500 - 2509
  • [38] Contrast-enhanced, ultrafast 3D pulmonary MR angiography in a single breath-hold: Initial assessment of imaging performance
    Steiner, P
    McKinnon, GC
    Romanowski, B
    Goehde, SC
    Hany, T
    Debatin, JF
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (01) : 177 - 182
  • [39] Clinical feasibility of 3D-QALAS - Single breath-hold 3D myocardial T1 and T2-mapping
    Kvernby, Sofia
    Warntjes, Marcel
    Engvall, Jan
    Carlhall, Carl-Johan
    Ebbers, Tino
    MAGNETIC RESONANCE IMAGING, 2017, 38 : 13 - 20
  • [40] Evaluation of renal artery stenosis with breath-hold 3D dynamic gadolinium-enhanced MR angiography (MRA): A two-years experience
    De Cobelli, F
    Vanzulli, A
    Scifo, P
    Salvioni, M
    Venturini, M
    Del Maschio, A
    RADIOLOGY, 1998, 209P : 185 - 185