3D Late Gadolinium Enhancement in a Single Prolonged Breath-Hold using Supplemental Oxygenation and Hyperventilation

被引:12
|
作者
Roujol, Sebastien [1 ,2 ]
Basha, Tamer A. [1 ,2 ]
Akcakaya, Mehmet [1 ,2 ]
Foppa, Murilo [1 ,2 ]
Chan, Raymond H. [1 ,2 ]
Kissinger, Kraig V. [1 ,2 ]
Goddu, Beth [1 ,2 ]
Berg, Sophie [1 ,2 ]
Manning, Warren J. [1 ,2 ,3 ]
Nezafat, Reza [1 ,2 ]
机构
[1] Beth Israel Deaconess Med Ctr, Dept Med, Div Cardiovasc, Boston, MA 02215 USA
[2] Harvard Univ, Sch Med, Boston, MA USA
[3] Beth Israel Deaconess Med Ctr, Dept Radiol, Boston, MA 02215 USA
基金
美国国家卫生研究院;
关键词
late gadolinium enhancement; myocardial viability; 3D acquisition; acceleration techniques; breath-hold; left ventricle; hyperventilation; compressed sensing; SENSITIVE INVERSION-RECOVERY; CORONARY MR-ANGIOGRAPHY; MYOCARDIAL-INFARCTION; DELAYED HYPERENHANCEMENT; IMAGE-RECONSTRUCTION; ATRIAL-FIBRILLATION; SPATIAL-RESOLUTION; CARDIAC MR; VIABILITY; MOTION;
D O I
10.1002/mrm.24969
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the feasibility of three-dimensional (3D) single breath-hold late gadolinium enhancement (LGE) of the left ventricle (LV) using supplemental oxygen and hyperventilation and compressed-sensing acceleration. Methods: Breath-hold metrics [breath-hold duration, diaphragmatic/LV position drift, and maximum variation of R wave to R wave (RR) interval] without and with supplemental oxygen and hyperventilation were assessed in healthy adult subjects using a real-time single shot acquisition. Ten healthy subjects and 13 patients then underwent assessment of the proposed 3D breath-hold LGE acquisition (field of view = 320 x 320 x 100 mm(3), resolution = 1.6 x 1.6 x 5.0 mm(3), acceleration rate of 4) and a free-breathing acquisition with right hemidiaphragm navigator (NAV) respiratory gating. Semiquantitative grading of overall image quality, motion artifact, myocardial nulling, and diagnostic value was performed by consensus of two blinded observers. Results: Supplemental oxygenation and hyperventilation increased the breath-hold duration (35+/-11 s to 58+/-21 s; P< 0.0125) without significant impact on diaphragmatic/LV position drift or maximum variation of RR interval (both P> 0.01). LGE images were of similar quality when compared with free-breathing acquisitions, but with reduced total scan time (85+/-22 s to 35+/-6 s; P< 0.001). Conclusions: Supplemental oxygenation and hyperventilation allow for prolonged breath-holding and enable single breath-hold 3D accelerated LGE with similar image quality as free breathing with NAV. (C) 2013 Wiley Periodicals, Inc.
引用
收藏
页码:850 / 857
页数:8
相关论文
共 50 条
  • [1] Time-resolved early-to-late Gadolinium enhancement MRI using single breath-hold 3D spiral imaging
    Taehoon Shin
    Dwight G Nishimura
    Michael V McConnell
    Bob S Hu
    Journal of Cardiovascular Magnetic Resonance, 14 (Suppl 1)
  • [2] Comparison of free breathing 3D mDIXON with single breath-hold 3D inversion recovery sequences for the assessment of Late Gadolinium Enhancement
    Dessouky, Riham
    De Stasio, Vincenzo
    Boccalini, Sara
    Si-Mohamed, Salim
    Broussaud, Thomas
    Douek, Philippe
    Sigovan, Monica
    EUROPEAN JOURNAL OF RADIOLOGY, 2021, 134
  • [3] Feasibility study of a single breath-hold, 3D mDIXON pulse sequence for late gadolinium enhancement imaging of ischemic scar
    Foley, James R. J.
    Fent, Graham J.
    Garg, Pankaj
    Broadbent, David A.
    Dobson, Laura E.
    Chew, Pei G.
    Brown, Louise A. E.
    Swoboda, Peter P.
    Plein, Sven
    Higgins, David M.
    Greenwood, John P.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2019, 49 (05) : 1437 - 1445
  • [4] SINGLE BREATH-HOLD, 3D MDIXON PULSE SEQUENCE FOR LATE GADOLINIUM ENHANCEMENT IMAGING OF ISCHAEMIC SCAR: A FEASIBILITY STUDY
    Foley, James R. J.
    Fent, Graham J.
    Garg, Pankaj
    Broadbent, David
    Dobson, Laura E.
    Chew, Pei G.
    Brown, Louise A. E.
    Swoboda, Peter P.
    Plein, Sven
    Higgins, David M.
    Greenwood, John P.
    HEART, 2018, 104 : A12 - A12
  • [5] Single breath-hold 3D LGE using stack of spiral trajectory
    Yang Yang
    Peter Shaw
    Jorge A Gonzalez
    Christopher M Kramer
    Michael Salerno
    Journal of Cardiovascular Magnetic Resonance, 17 (Suppl 1)
  • [6] Rapid Single-Breath-Hold 3D Late Gadolinium Enhancement Cardiac MRI Using a Stack-of-Spirals Acquisition
    Shin, Taehoon
    Lustig, Michael
    Nishimura, Dwight G.
    Hu, Bob S.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2014, 40 (06) : 1496 - 1502
  • [7] Single breath-hold assessment of cardiac function using an accelerated 3D single breath-hold acquisition technique - comparison of an intravascular and extravascular contrast agent
    Marcus R Makowski
    Andrea J Wiethoff
    Christian HP Jansen
    Sergio Uribe
    Victoria Parish
    Andreas Schuster
    Rene M Botnar
    Aaron Bell
    Christoph Kiesewetter
    Reza Razavi
    Tobias Schaeffter
    Gerald F Greil
    Journal of Cardiovascular Magnetic Resonance, 14
  • [8] Single breath-hold assessment of cardiac function using an accelerated 3D single breath-hold acquisition technique - comparison of an intravascular and extravascular contrast agent
    Makowski, Marcus R.
    Wiethoff, Andrea J.
    Jansen, Christian H. P.
    Uribe, Sergio
    Parish, Victoria
    Schuster, Andreas
    Botnar, Rene M.
    Bell, Aaron
    Kiesewetter, Christoph
    Razavi, Reza
    Schaeffter, Tobias
    Greil, Gerald F.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2012, 14
  • [9] Breath-hold 3D MR coronary angiography
    Wielopolski, PA
    Oudkerk, M
    DeBruin, HG
    DeJaegere, P
    DeFeyter, P
    RADIOLOGY, 1996, 201 : 785 - 785
  • [10] Quantitative breath-hold monitoring of myocardial gadolinium enhancement using inversion recovery TrueFISP
    Goldfarb, JW
    Mathew, ST
    Reichek, N
    MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (02) : 367 - 371