Comparing the Accuracy of Digital Subtraction Angiography, CT Angiography and MR Angiography at Estimating the Volume of Cerebral Aneurysms

被引:11
|
作者
Hanley, M. [1 ]
Zenzen, W. J. [1 ]
Brown, M. D. [1 ]
Gaughen, J. R. [1 ]
Evans, A. J. [1 ]
机构
[1] Univ Virginia Hlth Syst, Charlottesville, VA USA
来源
INTERVENTIONAL NEURORADIOLOGY | 2008年 / 14卷 / 02期
关键词
intracranial aneurysm; cerebral angiography; volume measurement;
D O I
10.1177/159101990801400208
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
While there are many studies that compare imaging modalities in the detection of cerebral aneurysms there are no existing studies that compare two dimensional digital subtraction angiography (DSA), CT angiography (CTA) and MR angiography (MRA) in calculating the volume of cerebral aneurysms. This study will compare these imaging modalities on seven in-vitro models of known volume. Seven silicone models of cerebral aneurysms were chosen representing slight variations in geometric shape and size. The volume of each model was measured by weighing the amount of water required to fill the aneurysm to the parent artery. Contrast enhanced images of the models were taken with DSA, CTA and MRA. The images were interpreted by four independent readers and the volumes were calculated. The measured volumes from the water weight analysis were compared to the volumes calculated from the interpreter's measurements. The accuracy of DSA, CTA and MRA were compared using the Percent of absolute and true variance from the measured volume. The average percent absolute variance for DSA was 14.3%, CTA was 16.8% and MRA was 18.6%. While these differences were minimal, comparing the percent of true variance demonstrated an average variance of -1.9% for DSA, 16.1% for CTA and -15.9% for MRA. Calculating the volume of cerebral aneurysms, while increasingly important, is difficult and error prone. It is important to understand the limitations and inherent errors before relying on calculated volumes in clinical decision-making. Regardless of imaging modality, one should consider error rates of 14-19% for calculating volume while keeping in mind the tendency for CTA to overestimate volume, MRA to underestimate volume and DSA to both under and overestimate equally.
引用
收藏
页码:173 / 177
页数:5
相关论文
共 50 条
  • [21] ANGIOGRAPHY AND DIGITAL SUBTRACTION ANGIOGRAPHY
    KOLLATH, J
    MONATSSCHRIFT KINDERHEILKUNDE, 1986, 134 (06) : 369 - 372
  • [22] Comparison of the accuracy of subtraction CT angiography performed on 320-detector row volume CT with conventional CT angiography for diagnosis of intracranial aneurysms
    Luo, Zhuren
    Wang, Dan
    Sun, Xilin
    Zhang, Tong
    Liu, Fang
    Dong, Dandan
    Chan, Nicholas K.
    Shen, Baozhong
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (01) : 118 - 122
  • [23] Subtraction CT angiography for evaluation of intracranial aneurysms: comparison with conventional CT angiography
    Li, Qi
    Lv, Fajin
    Li, Yongmei
    Li, Kewei
    Luo, Tianyou
    Xie, Peng
    EUROPEAN RADIOLOGY, 2009, 19 (09) : 2261 - 2267
  • [24] Subtraction CT angiography for evaluation of intracranial aneurysms: comparison with conventional CT angiography
    Qi Li
    Fajin Lv
    Yongmei Li
    Kewei Li
    Tianyou Luo
    Peng Xie
    European Radiology, 2009, 19 : 2261 - 2267
  • [25] CT angiography of cerebral aneurysms
    Idjuski, S
    Senicar, S
    Till, V
    Stojanovic, S
    Nikolic, O
    RIVISTA DI NEURORADIOLOGIA, 2003, 16 (05): : 985 - 987
  • [26] Dynamic MR digital subtraction angiography
    Klisch, J
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2001, 22 (08) : 1632 - 1632
  • [27] Diagnostic yield and accuracy of CT angiography, MR angiography and digital subtraction angiography for detection of macrovascular causes of intracerebral haemorrhage - a prospective, multicentre cohort study
    van Asch, C. J. J.
    Velthuis, B. K.
    Rinkel, G. J. E.
    Algra, A.
    Greving, J. P.
    de Kort, G. A. P.
    Witkamp, T. W.
    de Ridder, J. C. M.
    de Leeuw, F. E.
    Schonewille, W. J.
    de Kort, P. L.
    Dippel, D. W.
    Raaijmakers, T. W. M.
    Hofmeijer, J.
    Wermer, M. J. H.
    Kerkhoff, H.
    Jellema, K.
    Bronner, I. M.
    Remmers, M. J. M.
    Bienfait, H. P.
    INTERNATIONAL JOURNAL OF STROKE, 2015, 10 : 299 - 299
  • [28] Diagnostic yield and accuracy of CT angiography, MR angiography, and digital subtraction angiography for detection of macrovascular causes of intracerebral haemorrhage: prospective, multicentre cohort study
    van Asch, Charlotte J. J.
    Velthuis, Birgitta K.
    Rinkel, Gabrel J. E.
    Algra, Ale
    de Kort, Gerard A. P.
    Witkamp, Theo D.
    de Ridder, Johanna C. M.
    van Nieuwenhuizen, Koen M.
    de Leeuw, Frank-Erik
    Schonewille, Wouter J.
    de Kort, Paul L. M.
    Dippel, Diederik W.
    Raaymakers, Theodora W. M.
    Hofmeijer, Jeannette
    Wermer, Marieke J. H.
    Kerkhoff, Henk
    Jellema, Korne
    Bronner, Irene M.
    Remmers, Michel J. M.
    Bienfait, Henri Paul
    Witjes, Ron J. G. M.
    Greving, Jacoba P.
    Klijn, Catharina J. M.
    BMJ-BRITISH MEDICAL JOURNAL, 2015, 351
  • [29] Comparison of three-dimensional rotational angiography with digital subtraction angiography in the assessment of ruptured cerebral aneurysms
    Hochmuth, A
    Spetzger, U
    Schumacher, M
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2002, 23 (07) : 1199 - 1205
  • [30] Comparison of computed tomographic angiography with digital subtraction angiography in the diagnosis of cerebral aneurysms: A meta-analysis
    Chappell, ET
    Moure, FC
    Good, MC
    NEUROSURGERY, 2003, 52 (03) : 624 - 630