Subtraction CT angiography for evaluation of intracranial aneurysms: comparison with conventional CT angiography

被引:0
|
作者
Qi Li
Fajin Lv
Yongmei Li
Kewei Li
Tianyou Luo
Peng Xie
机构
[1] The First Affiliated Hospital,Department of Neurology
[2] Chongqing Medical University,Department of Radiology
[3] The First Affiliated Hospital,undefined
[4] Chongqing Medical University,undefined
来源
European Radiology | 2009年 / 19卷
关键词
Computed tomography angiography; Subarachnoid haemorrhage; Intracranial aneurysm; Digital subtraction angiography;
D O I
暂无
中图分类号
学科分类号
摘要
The purpose of our study was to compare the diagnostic performance of subtraction computed tomography angiography (CTA) with conventional nonsubtracted CTA and digital subtraction angiography (DSA) for the detection of intracranial aneurysms. A total of 76 patients underwent both subtraction CTA and conventional CTA for the detection and therapy planning of suspected intracranial aneurysms. Subtraction and conventional CTA images were independently assessed by two readers in a blinded manner. The possibility of endovascular treatment or surgical clipping was also assessed based on information provided by CT angiograms alone. In 64 patients, 75 aneurysms were present on DSA. On a per-aneurysm basis, the sensitivity of subtraction CTA was 98.6% for reader 1, and 100% for reader 2. However, sensitivity of conventional CTA was 94.6% for reader 1, and 93.3% for reader 2. Therapeutic decisions could be made regarding 63 patients based on information provided by subtraction CTA images. However, conventional CTA provided sufficient information to make this decision for 55 patients. Conventional CTA has limited sensitivity in detecting very small aneurysms as well as aneurysms adjacent to bone. Subtraction CTA performed on a 64-row multidetector CT is an accurate and promising diagnostic tool that seems to be equivalent to 2D DSA for the detection and pretreatment planning of intracranial aneurysms.
引用
收藏
页码:2261 / 2267
页数:6
相关论文
共 50 条
  • [1] Subtraction CT angiography for evaluation of intracranial aneurysms: comparison with conventional CT angiography
    Li, Qi
    Lv, Fajin
    Li, Yongmei
    Li, Kewei
    Luo, Tianyou
    Xie, Peng
    EUROPEAN RADIOLOGY, 2009, 19 (09) : 2261 - 2267
  • [2] 320-Detector row CT angiography for detection and evaluation of intracranial aneurysms: Comparison with conventional digital subtraction angiography
    Wang, H.
    Li, W.
    He, H.
    Luo, L.
    Chen, C.
    Guo, Y.
    CLINICAL RADIOLOGY, 2013, 68 (01) : E15 - E20
  • [3] 3D bone subtraction CT angiography for the evaluation of intracranial aneurysms: a comparison study with 2D bone subtraction CT angiography and conventional non-subtracted CT angiography
    Cheng, Bochao
    Cai, Wu
    Sun, Chongran
    Kang, Yan
    Gong, Jianping
    ACTA RADIOLOGICA, 2015, 56 (09) : 1127 - 1134
  • [4] Bone-subtraction CT angiography for the evaluation of intracranial aneurysms
    Tomandl, BF
    Hammen, T
    Klotz, E
    Ditt, H
    Stemper, B
    Lell, M
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2006, 27 (01) : 55 - 59
  • [5] Comparison of the accuracy of subtraction CT angiography performed on 320-detector row volume CT with conventional CT angiography for diagnosis of intracranial aneurysms
    Luo, Zhuren
    Wang, Dan
    Sun, Xilin
    Zhang, Tong
    Liu, Fang
    Dong, Dandan
    Chan, Nicholas K.
    Shen, Baozhong
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (01) : 118 - 122
  • [6] Detection of intracranial aneurysms with multislice CT: comparison with conventional angiography
    Dammert, S
    Krings, T
    Moller-Hartmann, W
    Ueffing, E
    Hans, FJ
    Willmes, K
    Mull, M
    Thron, A
    NEURORADIOLOGY, 2004, 46 (06) : 427 - 434
  • [7] Detection of intracranial aneurysms with multislice CT: comparison with conventional angiography
    S. Dammert
    T. Krings
    W. Moller-Hartmann
    E. Ueffing
    F. J. Hans
    K. Willmes
    M. Mull
    A. Thron
    Neuroradiology, 2004, 46 : 427 - 434
  • [8] Bone subtraction CT angiography for the detection of intracranial aneurysms
    Ramasundara, S.
    Mitchell, P. J.
    Dowling, R. J.
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2010, 54 (06) : 526 - 533
  • [9] Comparison of 16-row multislice CT angiography with conventional angiography for detection and evaluation of intracranial aneurysms
    Donmez, Halil
    Serifov, Elman
    Kahriman, Guven
    Mavili, Ertugrul
    Durak, Ahmet Candan
    Menku, Ahmet
    EUROPEAN JOURNAL OF RADIOLOGY, 2011, 80 (02) : 455 - 461
  • [10] Detection and evaluation of intracranial aneurysms with 16-row multislice CT angiography: Comparison with conventional angiography
    Uysal E.
    Oztora F.
    Ozel A.
    Erturk S.M.
    Yıldırım H.
    Basak M.
    Emergency Radiology, 2008, 15 (5) : 311 - 316