Two-Sided Coded-Aperture Imaging Without a Detector Plane

被引:0
|
作者
Ziock, K. P. [1 ]
Cunningham, M. [1 ]
Fabris, L. [1 ]
机构
[1] Oak Ridge Natl Lab, Oak Ridge, TN 37831 USA
关键词
Coded-aperture imager; gamma-ray detectors; gamma-ray imagers; orphan source search; nuclear imaging; LARGE-AREA; SENSITIVITY; ARRAYS; IMAGER;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We introduce a novel design for a two-sided, coded-aperture, gamma-ray imager suitable for use in stand off detection of orphan radioactive sources. The design is an extension of an active-mask imager that would have three active planes of detector material, a central plane acting as the detector for two (active) coded-aperture mask planes, one on either side of the detector plane. In the new design the central plane is removed and the mask on the left (right) serves as the detector plane for the mask on the right (left). This design reduces the size, mass, complexity, and cost of the overall instrument. In addition, if one has fully position-sensitive detectors, then one can use the two planes as a classic Compton camera. This enhances the instrument's sensitivity at higher energies where the coded-aperture efficiency is decreased by mask penetration. A plausible design for the system is found and explored with Monte Carlo simulations.
引用
收藏
页码:5567 / 5574
页数:8
相关论文
共 50 条
  • [41] Impact of mask thickness on the imaging performance of the coded-aperture gamma camera
    Zhu, B.
    Wang, Z.
    Zheng, Z.
    Zhou, R.
    Yang, C.
    JOURNAL OF INSTRUMENTATION, 2022, 17 (05)
  • [42] Fast Terahertz Coded-Aperture Imaging Based on Convolutional Neural Network
    Gan, Fengjiao
    Luo, Chenggao
    Liu, Xingyue
    Wang, Hongqiang
    Peng, Long
    APPLIED SCIENCES-BASEL, 2020, 10 (08):
  • [43] ADVANCED CODED-APERTURE IMAGING-SYSTEM FOR NUCLEAR-MEDICINE
    OHYAMA, N
    HONDA, T
    TSUJIUCHI, J
    MATUMOTO, T
    IINUMA, TA
    ISHIMATSU, K
    APPLIED OPTICS, 1983, 22 (22): : 3555 - 3561
  • [44] Simulation Research of Terahertz Coded-aperture Imaging Technology with High Resolution
    Cao, Kaicheng
    Luo, Chenggao
    Cheng, Yongqiang
    Deng, Bin
    Qin, Yuliang
    Wang, Hongqiang
    Chen, Shuo
    2016 PROGRESS IN ELECTROMAGNETICS RESEARCH SYMPOSIUM (PIERS), 2016, : 3414 - 3418
  • [45] A novel method for assessing imaging quality of coded-aperture gamma-ray camera to radioactive plane source
    Zhao, Mingyang
    Wang, Zhonghai
    Zhu, Balin
    Bai, Lixin
    Zhou, Rong
    Yang, Chaowen
    JOURNAL OF INSTRUMENTATION, 2023, 18 (03)
  • [46] Lensless coded-aperture imaging with separable Doubly-Toeplitz masks
    DeWeert, Michael J.
    Farm, Brian P.
    OPTICAL ENGINEERING, 2015, 54 (02)
  • [47] CODED-APERTURE IMAGING-SYSTEM FOR RECONSTRUCTING TOMOGRAMS OF HUMAN MYOCARDIUM
    OHYAMA, N
    ENDO, T
    HONDA, T
    TSUJIUCHI, J
    MATUMOTO, T
    IINUMA, TA
    ISHIMATSU, K
    APPLIED OPTICS, 1984, 23 (18): : 3168 - 3173
  • [48] ANALOG DECONVOLUTION IN CODED-APERTURE IMAGING APPLIED TO NUCLEAR-MEDICINE
    BRUNOL, J
    FONROGET, Y
    LOWENTHAL, S
    OPTICA ACTA, 1978, 25 (02): : 113 - 124
  • [49] Coded-Aperture imaging based on random code and Backpropagation neural network
    Wang, Zeyu
    Wang, Chao
    Gong, Pin
    Li, Liansheng
    Hu, Zhimeng
    Shi, Yongqiang
    Shen, Xiaolei
    Zhou, Cheng
    Zhu, Xiaoxiang
    Tang, Xiaobin
    ANNALS OF NUCLEAR ENERGY, 2024, 195
  • [50] OPTICAL-POSITION SENSING FOR ROBOTICS USING CODED-APERTURE IMAGING
    SWEENEY, DW
    HUDELSON, GD
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1982, 72 (12) : 1827 - 1827