Two-Sided Coded-Aperture Imaging Without a Detector Plane

被引:0
|
作者
Ziock, K. P. [1 ]
Cunningham, M. [1 ]
Fabris, L. [1 ]
机构
[1] Oak Ridge Natl Lab, Oak Ridge, TN 37831 USA
关键词
Coded-aperture imager; gamma-ray detectors; gamma-ray imagers; orphan source search; nuclear imaging; LARGE-AREA; SENSITIVITY; ARRAYS; IMAGER;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We introduce a novel design for a two-sided, coded-aperture, gamma-ray imager suitable for use in stand off detection of orphan radioactive sources. The design is an extension of an active-mask imager that would have three active planes of detector material, a central plane acting as the detector for two (active) coded-aperture mask planes, one on either side of the detector plane. In the new design the central plane is removed and the mask on the left (right) serves as the detector plane for the mask on the right (left). This design reduces the size, mass, complexity, and cost of the overall instrument. In addition, if one has fully position-sensitive detectors, then one can use the two planes as a classic Compton camera. This enhances the instrument's sensitivity at higher energies where the coded-aperture efficiency is decreased by mask penetration. A plausible design for the system is found and explored with Monte Carlo simulations.
引用
收藏
页码:5567 / 5574
页数:8
相关论文
共 50 条
  • [21] A New Pad-Based Neutron Detector for Stereo Coded-Aperture Thermal Neutron Imaging
    Dioszegi, I.
    Yu, B.
    Smith, G.
    Schaknowski, N.
    Fried, J.
    Vanier, P. E.
    Salwen, C.
    Forman, L.
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [22] Portable instrument for coded-aperture imaging of γ-ray sources
    Ivanov, OP
    Stepanov, VE
    Sudarkin, AN
    Urutskoev, LI
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1998, 41 (04) : 563 - 568
  • [23] Portable instrument for coded-aperture imaging of γ-ray sources
    Ivanov, O.P.
    Stepanov, V.E.
    Sudarkin, A.N.
    Urutskoev, L.I.
    Pribory i Tekhnika Eksperimenta, 1998, (04):
  • [24] Gamma Imaging Using Hybrid Coded-Aperture and Compton Scatter Imaging
    Montz, B.
    Hayward, J.
    Ramsey, C.
    MEDICAL PHYSICS, 2022, 49 (06) : E209 - E209
  • [25] Antenna Phase Error Compensation for Terahertz Coded-Aperture Imaging
    Liu, Xingyue
    Luo, Chenggao
    Gan, Fengjiao
    Wang, Hongqiang
    Peng, Long
    Wang, Yu
    ELECTRONICS, 2020, 9 (04)
  • [26] DILUTE UNIFORMLY REDUNDANT SEQUENCES FOR USE IN CODED-APERTURE IMAGING
    WILD, WJ
    OPTICS LETTERS, 1983, 8 (05) : 247 - 249
  • [27] OBJECT DEPENDENT SYSTEM-DESIGN IN CODED-APERTURE IMAGING
    PAXMAN, RG
    BARRETT, HH
    SMITH, WE
    ACTA POLYTECHNICA SCANDINAVICA-APPLIED PHYSICS SERIES, 1985, (149): : 285 - 285
  • [28] Phaseless Terahertz Coded-Aperture Imaging Based on Incoherent Detection
    Peng, Long
    Luo, Chenggao
    Deng, Bin
    Wang, Hongqiang
    Qin, Yuliang
    Chen, Shuo
    SENSORS, 2019, 19 (02):
  • [29] THE CONSEQUENCES OF MULTIPLEXING AND LIMITED VIEW ANGLE IN CODED-APERTURE IMAGING
    SMITH, WE
    BARRETT, HH
    PAXMAN, RG
    JOURNAL OF NUCLEAR MEDICINE, 1984, 25 (05) : P55 - P55
  • [30] CHARACTERIZATION OF TERAHERTZ ANTENNAS USING PHOTOINDUCED CODED-APERTURE IMAGING
    Shams, M. I. B.
    Jiang, Z.
    Qayyum, J.
    Rahman, S. M.
    Xing, H. G.
    Hesler, J. L.
    Fay, P.
    Liu, L.
    MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 2015, 57 (05) : 1180 - 1184