Detection of left atrial appendage thrombi by third-generation dual-source dual-energy CT: Iodine concentration versus conventional enhancement measurements

被引:17
|
作者
Li, Wenhuan [1 ,3 ]
Yu, Fangfang [1 ,3 ]
Zhu, Weiwei [2 ,4 ]
Zhang, Weiguo [1 ]
Jiang, Tao [1 ]
机构
[1] Capital Med Univ, Beijing Chao Yang Hosp, Dept Radiol, Beijing, Peoples R China
[2] Capital Med Univ, Beijing Chao Yang Hosp, Heart Ctr, Dept Echocardiog, Beijing, Peoples R China
[3] Beijing Chao Yang Hosp, Dept Radiol, 8 Gongren Tiyuchang Nanlu, Beijing 100020, Peoples R China
[4] Beijing Chao Yang Hosp, Dept Echocardiog, 8 Gongren Tiyuchang Nanlu, Beijing 100020, Peoples R China
关键词
CARDIAC COMPUTED-TOMOGRAPHY; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; CATHETER ABLATION; PULMONARY VEIN; ESOPHAGEAL HEMATOMA; STROKE PATIENTS; LIFETIME RISK; FIBRILLATION; ANGIOGRAPHY; MANAGEMENT;
D O I
10.1016/j.ijcard.2019.04.079
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Dual-energy computed tomography (DECT) can differentiate iodine from other materials through the material decomposition technique. The purpose of this study was to compare the diagnostic performance of DECT-derived iodine concentration (mg/ml) with conventional enhancement measurements (HU), in detecting left atrial appendage (LAA) thrombi and differentiating thrombi from circulatory stasis in atrial fibrillation (AF) patients referred for catheter ablation. Methods: Consecutive patients were prospectively recruited and scanned using a third-generation dual-source CT system in dual-energy mode. Regions of interest were placed inside the filling defect in the LAA and ascending aorta (AA) of the same sections, to determine iodine concentration and the LAA/AA HU ratio. The diagnostic performance of iodine concentration and LAA/AA HU ratios were compared using transesophageal echocardiography (TEE) as the reference standard. Results: Among 302 patients, 10 thrombi and 27 cases with spontaneous echo contrast (SEC) were detected by TEE. Diagnostic accuracy, sensitivity, specificity, positive predictive value, and negative predictive value of iodine concentration were superior to those of LAA/AA HU ratios (iodine concentration: 99.7%, 100%, 99.7%, 90.9%, and 100% vs. LAA/AA HU ratios: 96.0%, 100%, 95.9%, 45.5%, and 100%) in detecting LAA thrombi. The area under the receiver operating characteristic curve of iodine concentration (0.996; 0.898-1.000) was significantly larger than that of the LAA/AAHU ratio (0.881; 0.733-0.964) in differentiating thrombi from circulatory stasis (p < 0.05). Conclusions: DECT-derived iodine concentration was associated with improved diagnostic accuracy compared with conventional enhancement measurements in detecting LAA thrombi and differentiating thrombi from circulatory stasis in AF patients. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页码:265 / 270
页数:6
相关论文
共 50 条
  • [41] Spectral Optimization of Chest CT Angiography with Reduced Iodine Load: Experience in 80 Patients Evaluated with Dual-Source, Dual-Energy CT
    Delesalle, Marie-Aurelie
    Pontana, Francois
    Duhamel, Alain
    Faivre, Jean-Baptiste
    Flohr, Thomas
    Tacelli, Nunzia
    Remy, Jacques
    Remy-Jardin, Martine
    RADIOLOGY, 2013, 267 (01) : 256 - 266
  • [42] Strengths and limitations of coronary angiography with turbo high-pitch third-generation dual-source CT
    Ochs, M. M.
    Andre, F.
    Korosoglou, G.
    Fritz, T.
    Seitz, S.
    Bogomazov, Y.
    Schlett, C. L.
    Sokiranski, R.
    Sommer, A.
    Gueckel, F.
    Brado, M.
    Kauczor, H. -U.
    Goerich, J.
    Buss, S. J.
    CLINICAL RADIOLOGY, 2017, 72 (09) : 739 - 744
  • [43] Myocardial late enhancement using dual-source CT: intraindividual comparison of single-energy shuttle and dual-energy acquisition
    Takanori Kokawa
    Kakuya Kitagawa
    Satoshi Nakamura
    Masafumi Takafuji
    Takashi Oya
    Hajime Sakuma
    Insights into Imaging, 16 (1)
  • [44] Abdominal Organs Attenuation Values and Abdominal Aortic Calcifications on Virtual and True Noncontrast Images Obtained With Third-Generation Dual-Source Dual-Energy Computed Tomography
    Kim, Sungmin
    Kang, Byeong Seong
    Kwon, Woon-Jung
    Bang, Minseo
    Lim, Soyeoun
    Park, Gyeong Min
    Lee, Tae Young
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2020, 44 (04) : 490 - 500
  • [45] Radiation exposure related to cardiovascular CT examination: comparison between conventional 64-MDCT and third-generation dual-source MDCT
    Agliata, Giacomo
    Schicchi, Nicola
    Agostini, Andrea
    Fogante, Marco
    Mari, Alberto
    Maggi, Stefania
    Giovagnoni, Andrea
    RADIOLOGIA MEDICA, 2019, 124 (08): : 753 - 761
  • [46] Radiation exposure related to cardiovascular CT examination: comparison between conventional 64-MDCT and third-generation dual-source MDCT
    Giacomo Agliata
    Nicolò Schicchi
    Andrea Agostini
    Marco Fogante
    Alberto Mari
    Stefania Maggi
    Andrea Giovagnoni
    La radiologia medica, 2019, 124 : 753 - 761
  • [47] Iodine quantification to distinguish hepatic neuroendocrine tumor metastasis from hepatocellular carcinoma at dual-source dual-energy liver CT
    Kaltenbach, Benjamin
    Wichmann, Julian L.
    Pfeifer, Sophia
    Albrecht, Moritz H.
    Booz, Christian
    Lenga, Lukas
    Hammerstingl, Renate
    Dangelo, Tommaso
    Vogl, Thomas J.
    Martin, Simon S.
    EUROPEAN JOURNAL OF RADIOLOGY, 2018, 105 : 20 - 24
  • [48] Pulmonary CT scans of white rabbits using the selective photon shield technique of the third-generation dual-source CT
    Sun, Wenjie
    Tan, Hui
    Wang, Yi
    Xie, An
    Tan, Xianzheng
    Liu, Peng
    Xu, Dan
    Huang, Feng
    JOURNAL OF RADIOLOGICAL PROTECTION, 2022, 42 (02)
  • [49] Coronary CT angiography (CCTA) using third-generation dual-source CT for ruling out in-stent restenosis
    J. Eckert
    P. Renczes-Janetzko
    M. Schmidt
    A. Magedanz
    T. Voigtländer
    A. Schmermund
    Clinical Research in Cardiology, 2019, 108 : 402 - 410
  • [50] Radiation dose of coronary CT angiography with a third-generation dual-source CT in a "real-world" patient population
    Kosmala, Aleksander
    Petritsch, Bernhard
    Weng, Andreas Max
    Bley, Thorsten Alexander
    Gassenmaier, Tobias
    EUROPEAN RADIOLOGY, 2019, 29 (08) : 4341 - 4348