Detection of left atrial appendage thrombi by third-generation dual-source dual-energy CT: Iodine concentration versus conventional enhancement measurements

被引:17
|
作者
Li, Wenhuan [1 ,3 ]
Yu, Fangfang [1 ,3 ]
Zhu, Weiwei [2 ,4 ]
Zhang, Weiguo [1 ]
Jiang, Tao [1 ]
机构
[1] Capital Med Univ, Beijing Chao Yang Hosp, Dept Radiol, Beijing, Peoples R China
[2] Capital Med Univ, Beijing Chao Yang Hosp, Heart Ctr, Dept Echocardiog, Beijing, Peoples R China
[3] Beijing Chao Yang Hosp, Dept Radiol, 8 Gongren Tiyuchang Nanlu, Beijing 100020, Peoples R China
[4] Beijing Chao Yang Hosp, Dept Echocardiog, 8 Gongren Tiyuchang Nanlu, Beijing 100020, Peoples R China
关键词
CARDIAC COMPUTED-TOMOGRAPHY; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; CATHETER ABLATION; PULMONARY VEIN; ESOPHAGEAL HEMATOMA; STROKE PATIENTS; LIFETIME RISK; FIBRILLATION; ANGIOGRAPHY; MANAGEMENT;
D O I
10.1016/j.ijcard.2019.04.079
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Dual-energy computed tomography (DECT) can differentiate iodine from other materials through the material decomposition technique. The purpose of this study was to compare the diagnostic performance of DECT-derived iodine concentration (mg/ml) with conventional enhancement measurements (HU), in detecting left atrial appendage (LAA) thrombi and differentiating thrombi from circulatory stasis in atrial fibrillation (AF) patients referred for catheter ablation. Methods: Consecutive patients were prospectively recruited and scanned using a third-generation dual-source CT system in dual-energy mode. Regions of interest were placed inside the filling defect in the LAA and ascending aorta (AA) of the same sections, to determine iodine concentration and the LAA/AA HU ratio. The diagnostic performance of iodine concentration and LAA/AA HU ratios were compared using transesophageal echocardiography (TEE) as the reference standard. Results: Among 302 patients, 10 thrombi and 27 cases with spontaneous echo contrast (SEC) were detected by TEE. Diagnostic accuracy, sensitivity, specificity, positive predictive value, and negative predictive value of iodine concentration were superior to those of LAA/AA HU ratios (iodine concentration: 99.7%, 100%, 99.7%, 90.9%, and 100% vs. LAA/AA HU ratios: 96.0%, 100%, 95.9%, 45.5%, and 100%) in detecting LAA thrombi. The area under the receiver operating characteristic curve of iodine concentration (0.996; 0.898-1.000) was significantly larger than that of the LAA/AAHU ratio (0.881; 0.733-0.964) in differentiating thrombi from circulatory stasis (p < 0.05). Conclusions: DECT-derived iodine concentration was associated with improved diagnostic accuracy compared with conventional enhancement measurements in detecting LAA thrombi and differentiating thrombi from circulatory stasis in AF patients. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页码:265 / 270
页数:6
相关论文
共 50 条
  • [31] Effects of Patient Size and Radiation Dose on Iodine Quanti fi cation in Dual-Source Dual-Energy CT
    Jiang, Xia
    Yang, Xiangyu
    Hintenlang, David E.
    White, Richard D.
    ACADEMIC RADIOLOGY, 2021, 28 (01) : 96 - 105
  • [32] Limits of the possible: diagnostic image quality in coronary angiography with third-generation dual-source CT
    Marco M. Ochs
    Fabian aus dem Siepen
    Thomas Fritz
    Florian Andre
    Gitsios Gitsioudis
    Grigorios Korosoglou
    Sebastian Seitz
    Yuriy Bogomazov
    Christopher L. Schlett
    Roman Sokiranski
    Andre Sommer
    Friedemann Gückel
    Matthias Brado
    Hans-Ulrich Kauczor
    Johannes Görich
    Matthias G. W. Friedrich
    Hugo A. Katus
    Sebastian J. Buss
    Clinical Research in Cardiology, 2017, 106 : 485 - 492
  • [33] Limits of the possible: diagnostic image quality in coronary angiography with third-generation dual-source CT
    Ochs, Marco M.
    Siepen, Fabian Aus Dem
    Fritz, Thomas
    Andre, Florian
    Gitsioudis, Gitsios
    Korosoglou, Grigorios
    Seitz, Sebastian
    Bogomazov, Yuriy
    Schlett, Christopher L.
    Sokiranski, Roman
    Sommer, Andre
    Gueckel, Friedemann
    Brado, Matthias
    Kauczor, Hans-Ulrich
    Goerich, Johannes
    Friedrich, Matthias G. W.
    Katus, Hugo A.
    Buss, Sebastian J.
    CLINICAL RESEARCH IN CARDIOLOGY, 2017, 106 (07) : 485 - 492
  • [34] ECG-gated dual-source CT for detection of left atrial appendage thrombus in patients undergoing catheter ablation for atrial fibrillation
    Kapa, Suraj
    Martinez, Matthew W.
    Williamson, Eric E.
    Ommen, Steve R.
    Syed, Imran S.
    Feng, DaLi
    Packer, Douglas L.
    Brady, Peter A.
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2010, 29 (02) : 75 - 81
  • [35] ECG-gated dual-source CT for detection of left atrial appendage thrombus in patients undergoing catheter ablation for atrial fibrillation
    Suraj Kapa
    Matthew W. Martinez
    Eric E. Williamson
    Steve R. Ommen
    Imran S. Syed
    DaLi Feng
    Douglas L. Packer
    Peter A. Brady
    Journal of Interventional Cardiac Electrophysiology, 2010, 29 : 75 - 81
  • [36] Endoleaks after Endovascular Abdominal Aortic Aneurysm Repair: Detection with Dual-Energy Dual-Source CT
    Stolzmann, Paul
    Frauenfelder, Thomas
    Pfammatter, Thomas
    Peter, Nicole
    Scheffel, Hans
    Lachat, Mario
    Schmidt, Bernhard
    Marincek, Borut
    Alkadhi, Hatem
    Schertler, Thomas
    RADIOLOGY, 2008, 249 (02) : 682 - 691
  • [37] Quantification of Cisplatin Using a Modified 3-Material Decomposition Algorithm at Third-Generation Dual-Source Dual-Energy Computed Tomography An Experimental Study
    Sofue, Keitaro
    Itoh, Toshihide
    Takahashi, Satoru
    Schmidt, Bernhard
    Shimada, Ryuji
    Negi, Noriyuki
    Sugimura, Kazuro
    Murakami, Takamichi
    INVESTIGATIVE RADIOLOGY, 2018, 53 (11) : 673 - 680
  • [38] Comprehensive Comparison of Virtual Monoenergetic and Linearly Blended Reconstruction Techniques in Third-Generation Dual-Source Dual-Energy Computed Tomography Angiography of the Thorax and Abdomen
    Albrecht, Moritz H.
    Trommer, Jesko
    Wichmann, Julian L.
    Scholtz, Jan-Erik
    Martin, Simon S.
    Lehnert, Thomas
    Vogl, Thomas J.
    Bodelle, Boris
    INVESTIGATIVE RADIOLOGY, 2016, 51 (09) : 582 - 590
  • [39] Iodine Images in Dual-energy CT: Detection of Hepatic Steatosis by Quantitative Iodine Concentration Values
    Stefanie Beck
    Laurenz Jahn
    Dominik Deniffel
    Isabelle Riederer
    Andreas Sauter
    Marcus R. Makowski
    Daniela Pfeiffer
    Journal of Digital Imaging, 2022, 35 : 1738 - 1747
  • [40] Iodine Images in Dual-energy CT: Detection of Hepatic Steatosis by Quantitative Iodine Concentration Values
    Beck, Stefanie
    Jahn, Laurenz
    Deniffel, Dominik
    Riederer, Isabelle
    Sauter, Andreas
    Makowski, Marcus R.
    Pfeiffer, Daniela
    JOURNAL OF DIGITAL IMAGING, 2022, 35 (06) : 1738 - 1747