Metallurgical aspects of failure in a broken femoral HIP prosthesis

被引:20
|
作者
Khouzani, M. Kiani [1 ]
Bahrami, A. [1 ]
Eslami, A. [1 ]
机构
[1] Isfahan Univ Technol, Dept Mat Engn, Esfahan 8415683111, Iran
关键词
Failure analysis; AISI 316L stainless steels; HIP prosthesis; Fatigue fracture; FATIGUE FAILURE; STEM; FRACTURE;
D O I
10.1016/j.engfailanal.2018.03.018
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
In this research failure of femoral hip prosthesis, made of AISI 316 L stainless steel, in a 69 years old patient with a weight of 70 kg was investigated. Replacement of the damaged cartilage and bone of the hip joint with prosthesis component through Total HIP Arthroplasty (THA) is a widely used surgery. Patients with this type of implants are anticipated to have a normal daily life with capability of performing routine physical activities for a period of 15 years. However, in investigated case, the failure had occurred in< 10 years. Optical and electron microscopy as well as hardness measurements were conducted to investigate possible causes of the failure. Results showed that high cycle fatigue was the failure mechanism. Microstructure of the investigated hip consisted of surprisingly high density of inclusions which should have caused the initiation and growth of fatigue cracks. Possible failure scenarios and mitigation strategies have been discussed in this regard.
引用
收藏
页码:168 / 178
页数:11
相关论文
共 50 条
  • [41] Cardiovascular collapse after femoral prosthesis surgery for acute hip fracture
    Pietak, S
    Holmes, J
    Matthews, R
    Petrasek, A
    Porter, B
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1997, 44 (02): : 198 - 201
  • [42] Loosening of total hip arthroplasty with a prosthesis employing a skirted femoral head
    Chen, PY
    Wu, CT
    Hou, CH
    Hou, SM
    JOURNAL OF THE FORMOSAN MEDICAL ASSOCIATION, 2005, 104 (05) : 370 - 373
  • [43] FRACTURE OF FEMORAL PROSTHESIS IN TOTAL HIP-REPLACEMENT ACCORDING TO CHARNLEY
    CARLSSON, AS
    GENTZ, CF
    STENPORT, J
    ACTA ORTHOPAEDICA SCANDINAVICA, 1977, 48 (06): : 650 - 655
  • [44] CEMENTED VERSUS UNCEMENTED FEMORAL COMPONENTS IN THE RING HIP-PROSTHESIS
    GODSIFF, SP
    EMERY, RJH
    HEYWOODWADDINGTON, MB
    THOMAS, TL
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1992, 74 (06): : 822 - 824
  • [45] A Distal Fluted, Proximal Modular Femoral Prosthesis in Revision Hip Arthroplasty
    Park, Myung-Sik
    Lee, Ju-Hong
    Park, Jong-Hyuk
    Ham, Dong-Hun
    Rhee, Yang-Keun
    JOURNAL OF ARTHROPLASTY, 2010, 25 (06): : 932 - 938
  • [46] The hollow prosthesis to reduce intramedullary pressure in cementless femoral hip arthroplasty
    Barden, B
    Seel, W
    Löer, F
    Konermann, H
    ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 2004, 142 (03): : 298 - 302
  • [47] MODIFICATION OF THE POSTEROLATERAL APPROACH TO THE HIP FOR INSERTION OF FEMORAL-HEAD PROSTHESIS
    MARCY, GH
    FLETCHER, RS
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1954, 36-A (01): : 142 - 143
  • [48] A LATERAL INTERMUSCULAR APPROACH TO THE HIP JOINT FOR REPLACEMENT OF THE FEMORAL HEAD BY A PROSTHESIS
    BURWELL, HN
    SCOTT, D
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1954, 36 (01): : 104 - 108
  • [49] ROENTGENOGRAPHIC DETERMINATION OF THE ROTATION POSITION OF THE FEMORAL PORTION OF THE HIP-PROSTHESIS
    NORMAN, O
    ACTA ORTHOPAEDICA SCANDINAVICA, 1979, 50 (03): : 349 - 349
  • [50] Thermoelastic femoral stress imaging for experimental evaluation of hip prosthesis design
    Hyodo, K
    Inomoto, M
    Ma, W
    Miyakawa, S
    Tateishi, T
    JSME INTERNATIONAL JOURNAL SERIES C-MECHANICAL SYSTEMS MACHINE ELEMENTS AND MANUFACTURING, 2001, 44 (04) : 1065 - 1071