The influence of stress conditions on the wear of UHMWPE for total joint replacements

被引:56
|
作者
Barbour, PSM
Barton, DC
Fisher, J
机构
[1] Department of Mechanical Engineering, University of Leeds, Leeds
基金
英国工程与自然科学研究理事会;
关键词
D O I
10.1023/A:1018515318630
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In vitro studies of the effect of contact stress on the wear of ultra high molecular weight polyethylene (UHMWPE) in orthopaedic applications have produced contradictory results which predict both increased and decreased wear with increasing contact stress. In vivo studies of functioning hip prostheses have reported that 22 mm femoral heads generate lower linear and volumetric wear rates than 32 mm femoral heads. The effect of decreasing the head size will increase the contact stress but decrease the sliding distance per motion cycle. The present study consists of wear experiments under a range of contact stress magnitudes and application conditions in order to simulate the wear processes occurring in vivo. The results from these tests indicated that the wear factor actually decreases with increasing contact stress if the stress was not varied with time. If a time dependent or spatially varying stress was applied, the wear factor can increase greatly when compared to similar magnitude constant contact stress. This effect may be due to the complex relationship between the rate of wear particle generation and the rate at which the particles are released from the interface. The results of these wear experiments are discussed in terms of the influence of the stress conditions upon potential wear processes in total hip and knee prostheses.
引用
收藏
页码:603 / 611
页数:9
相关论文
共 50 条
  • [41] Wear in total hip and knee replacements
    Schmalzried, TP
    Callaghan, JJ
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1999, 81A (01): : 115 - 136
  • [42] Prediction of lubricating film thickness in UHMWPE hip joint replacements
    Jalali-Vahid, D
    Jagatia, M
    Jin, ZM
    Dowson, D
    JOURNAL OF BIOMECHANICS, 2001, 34 (02) : 261 - 266
  • [43] Micro-wear patterns on UHMWPE tibial inserts in total knee joint simulation
    Tamura, J
    Clarke, IC
    Kawanabe, K
    Akagi, M
    Good, VD
    Williams, PA
    Masaoka, T
    Schroeder, D
    Oonishi, H
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 2002, 61 (02): : 218 - 225
  • [44] Effects of A-P translation and rotation on the wear of UHMWPE in a total knee joint simulator
    Kawanabe, K
    Clarke, IC
    Tamura, J
    Akagi, M
    Good, VD
    Williams, PA
    Yamamoto, K
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 2001, 54 (03): : 400 - 406
  • [45] Wear, oxidation and mechanical properties of a sequentially irradiated and annealed UHMWPE in total joint replacement
    Wang, A.
    Zeng, H.
    Yau, S-S
    Essner, A.
    Manely, M.
    Dumbleton, J.
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2006, 39 (15) : 3213 - 3219
  • [46] The influence of kinematic conditions and design on the wear of patella-femoral replacements
    Maiti, Raman
    Fisher, John
    Rowley, Liam
    Jennings, Louise M.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2014, 228 (02) : 175 - 181
  • [47] Prediction of lubricating film thickness in UHMWPE hip joint replacements
    Jin, ZM
    Jagatia, M
    Jalali-Vahid, D
    FRICTION, LUBRICATION, AND WEAR OF ARTIFICIAL JOINTS, 2003, : 75 - 87
  • [48] Wear behavior of carbon fiber reinforced peek composites in total joint replacements.
    Wang, A
    Lin, R
    Stark, C
    Dumbleton, JH
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1998, 216 : U892 - U892
  • [49] Lubrication and wear of ultra-high molecular weight polyethylene in total joint replacements
    Wang, A
    Essner, A
    Polineni, VK
    Sun, DC
    Stark, C
    Dumbleton, JH
    NEW DIRECTIONS IN TRIBOLOGY: PLENARY AND INVITED PAPERS FROM THE FIRST WORLD TRIBOLOGY CONGRESS, 1997, : 443 - 458
  • [50] WEAR OF POLYETHYLENE IN TOTAL JOINT REPLACEMENTS - OBSERVATIONS FROM RETRIEVED PCA KNEE IMPLANTS
    WRIGHT, TM
    RIMNAC, CM
    STULBERG, SD
    MINTZ, L
    TSAO, AK
    KLEIN, RW
    MCCRAE, C
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1992, (276) : 126 - 134