The influence of stress conditions on the wear of UHMWPE for total joint replacements

被引:56
|
作者
Barbour, PSM
Barton, DC
Fisher, J
机构
[1] Department of Mechanical Engineering, University of Leeds, Leeds
基金
英国工程与自然科学研究理事会;
关键词
D O I
10.1023/A:1018515318630
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In vitro studies of the effect of contact stress on the wear of ultra high molecular weight polyethylene (UHMWPE) in orthopaedic applications have produced contradictory results which predict both increased and decreased wear with increasing contact stress. In vivo studies of functioning hip prostheses have reported that 22 mm femoral heads generate lower linear and volumetric wear rates than 32 mm femoral heads. The effect of decreasing the head size will increase the contact stress but decrease the sliding distance per motion cycle. The present study consists of wear experiments under a range of contact stress magnitudes and application conditions in order to simulate the wear processes occurring in vivo. The results from these tests indicated that the wear factor actually decreases with increasing contact stress if the stress was not varied with time. If a time dependent or spatially varying stress was applied, the wear factor can increase greatly when compared to similar magnitude constant contact stress. This effect may be due to the complex relationship between the rate of wear particle generation and the rate at which the particles are released from the interface. The results of these wear experiments are discussed in terms of the influence of the stress conditions upon potential wear processes in total hip and knee prostheses.
引用
收藏
页码:603 / 611
页数:9
相关论文
共 50 条
  • [31] UHMWPE Wear Debris and Tissue Reactions Are Reduced for Contemporary Designs of Lumbar Total Disc Replacements
    Veruva, Sai Y.
    Lanman, Todd H.
    Isaza, Jorge E.
    MacDonald, Daniel W.
    Kurtz, Steven M.
    Steinbeck, Marla J.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2015, 473 (03) : 987 - 998
  • [32] The size and shape of particulate polyethylene wear debris in total joint replacements
    Kobayashi, A
    Bonfield, W
    Kadoya, Y
    Yamac, T
    Freeman, MAR
    Scott, G
    Revell, PA
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 1997, 211 (01) : 11 - 15
  • [33] Encoding Scratch and Scrape Features for Wear Modeling of Total Joint Replacements
    Kruger, Karen M.
    Tikekar, Nishant M.
    Heiner, Anneliese D.
    Baer, Thomas E.
    Lannutti, John J.
    Callaghan, John J.
    Brown, Thomas D.
    COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE, 2013, 2013
  • [34] Quantitative analysis of ultrahigh molecular weight polyethylene (UHMWPE) wear debris associated with total knee replacements
    Shanbhag, AS
    Bailey, HO
    Hwang, DS
    Cha, CW
    Eror, NG
    Rubash, HE
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 2000, 53 (01): : 100 - 110
  • [35] Wear and oxidation resistant UHMWPE with improved mechanical properties for total joint implants
    Fu, Jun
    Muratoglu, Orhun K.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2010, 240
  • [36] Standardized analysis of UHMWPE wear particles from failed total joint arthroplasties
    Mabrey, JD
    Afsar-Keshmiri, A
    Engh, GA
    Sychterz, CJ
    Wirth, MA
    Rockwood, CA
    Agrawal, CM
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 2002, 63 (05): : 475 - 483
  • [37] Finite element analysis of stress and wear characterization in total ankle replacements
    Elliot, Bradley Jay
    Gundapaneni, Dinesh
    Goswami, Tarun
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2014, 34 : 134 - 145
  • [38] Survivorship of Total Hip Joint Replacements Following Isolated Liner Exchange for Wear
    Vadei, Leone
    Kieser, David C.
    Frampton, Chris
    Hooper, Gary
    JOURNAL OF ARTHROPLASTY, 2017, 32 (11): : 3484 - 3487
  • [39] The influence of design, materials and kinematics on the in vitro wear of total knee replacements
    McEwen, HMJ
    Barnett, PI
    Bell, CJ
    Farrar, R
    Auger, DD
    Stone, MH
    Fisher, J
    JOURNAL OF BIOMECHANICS, 2005, 38 (02) : 357 - 365
  • [40] Wear in total hip and knee replacements
    Paling, IH
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (12): : 1806 - 1806