The influence of stress conditions on the wear of UHMWPE for total joint replacements

被引:56
|
作者
Barbour, PSM
Barton, DC
Fisher, J
机构
[1] Department of Mechanical Engineering, University of Leeds, Leeds
基金
英国工程与自然科学研究理事会;
关键词
D O I
10.1023/A:1018515318630
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In vitro studies of the effect of contact stress on the wear of ultra high molecular weight polyethylene (UHMWPE) in orthopaedic applications have produced contradictory results which predict both increased and decreased wear with increasing contact stress. In vivo studies of functioning hip prostheses have reported that 22 mm femoral heads generate lower linear and volumetric wear rates than 32 mm femoral heads. The effect of decreasing the head size will increase the contact stress but decrease the sliding distance per motion cycle. The present study consists of wear experiments under a range of contact stress magnitudes and application conditions in order to simulate the wear processes occurring in vivo. The results from these tests indicated that the wear factor actually decreases with increasing contact stress if the stress was not varied with time. If a time dependent or spatially varying stress was applied, the wear factor can increase greatly when compared to similar magnitude constant contact stress. This effect may be due to the complex relationship between the rate of wear particle generation and the rate at which the particles are released from the interface. The results of these wear experiments are discussed in terms of the influence of the stress conditions upon potential wear processes in total hip and knee prostheses.
引用
收藏
页码:603 / 611
页数:9
相关论文
共 50 条
  • [1] The influence of stress conditions on the wear of UHMWPE for total joint replacements
    P. S. M BARBOUR
    D. C BARTON
    J FISHER
    Journal of Materials Science: Materials in Medicine, 1997, 8 : 603 - 611
  • [2] Wear mechanisms of UHMWPE in total joint replacements
    Wang, A.
    Sun, D.C.
    Stark, C.
    Dumbleton, J.H.
    1600, (181-183):
  • [3] WEAR MECHANISMS OF UHMWPE IN TOTAL JOINT REPLACEMENTS
    WANG, A
    SUN, DC
    STARK, C
    DUMBLETON, JH
    WEAR, 1995, 181 : 241 - 249
  • [4] Structure modification of UHMWPE used for total joint replacements
    Nevoralová, M
    Baldrian, J
    Pospísil, J
    Chodák, I
    Horák, Z
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2005, 74B (02) : 800 - 807
  • [5] Surface modification of UHMWPE for use in total joint replacements
    Zhang, M
    James, SP
    King, R
    Beauregard, G
    BIOMEDICAL SCIENCES INSTRUMENTATION, VOL 40, 2004, 449 : 13 - 17
  • [6] Wear and osteolysis in total joint replacements
    Kadoya, Y
    Kobayashi, A
    Ohashi, H
    ACTA ORTHOPAEDICA SCANDINAVICA, 1998, 69 : 1 - 16
  • [7] Wear and osteolysis in total joint replacements
    Aspenberg, P
    Kadoya, Y
    Kobayashi, A
    Ohashi, H
    ACTA ORTHOPAEDICA SCANDINAVICA, 1998, 69 (04): : 435 - 436
  • [8] Investigation of wear and wear particles from a UHMWPE/multi-walled carbon nanotube nanocomposite for total joint replacements
    Suner, Silvia
    Bladen, Catherine L.
    Gowland, Nicholas
    Tipper, Joanne L.
    Emami, Nazanin
    WEAR, 2014, 317 (1-2) : 163 - 169
  • [9] Computational model of asperity contact for the prediction of UHMWPE mechanical and wear behaviour in total hip joint replacements
    Suhendra, N.
    Stachowiak, G. W.
    TRIBOLOGY LETTERS, 2007, 25 (01) : 8 - 22
  • [10] Computational model of asperity contact for the prediction of UHMWPE mechanical and wear behaviour in total hip joint replacements
    N. Suhendra
    G.W. Stachowiak
    Tribology Letters, 2007, 25 : 9 - 22