Prospects of Improving the Indoor Air Quality in Classrooms by Reactivating Historic Ventilation Stacks

被引:0
|
作者
Hellwig, Runa T. [1 ,2 ]
Sedlmeier, Michael [1 ]
Tanzer, Christian [1 ]
机构
[1] Augsburg Univ Appl Sci, Unit E2D Energy Efficiency Design, Augsburg, Germany
[2] Natl Univ Singapore, Dept Bldg, Sch Design & Environm, Cluster Solar & Energy Efficient Bldg,Solar Energ, Singapore 11757, Singapore
关键词
school building; ventilation stack; indoor air quality; historic ventilation system;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Stack ventilation systems were installed in German schools constructed around 1900 and are no longer in operation. The aim of this study was to show how reactivating these systems could improve the indoor air quality in classrooms. Ventilation stacks were reactivated in three classrooms in a school while a fourth classroom, which was naturally ventilated via openable windows, served as the reference case. All classrooms were measured for carbon dioxide levels, air temperature and relative humidity. During winter, 50% of all measured carbon dioxide values in the classroom with natural ventilation using windows were higher than 1800 ppm. All classrooms with stack ventilation showed median values of 1600 and 1350 ppm. In these classrooms, the volumetric flow rate per person in winter (14 m(3)/(h.pers)) was approximately seven times higher compared to the classroom with window ventilation (2 m(3)/(h.pers)). The supply stacks provided a preheating effect of 0.5 to 0.7 K/m. Effects of summer flow reversal were found in both of the classrooms with exhaust and supply ventilation stacks. Reactivating ventilation stacks provides the potential to improve indoor air quality in classrooms. Some adjustment of the systems, such as adding automated dampers to close the stacks at night and during flow reversal in summer, could allow the systems to meet today's hygienic and comfort requirements and turn them into modern low energy consuming systems.
引用
收藏
页码:141 / 152
页数:12
相关论文
共 50 条
  • [41] Improving the ventilation of a classroom to achieve heating energy savings and better indoor air quality
    Labihi, Abdelouhab
    Benakcha, Younes
    Meslem, Amina
    Byrne, Paul
    Collet, Florence
    BUILDING SERVICES ENGINEERING RESEARCH & TECHNOLOGY, 2024, 45 (03): : 275 - 291
  • [42] Improving energy performance of school buildings while ensuring indoor air quality ventilation
    Becker, Rachel
    Goldberger, Itamar
    Paciuk, Monica
    BUILDING AND ENVIRONMENT, 2007, 42 (09) : 3261 - 3276
  • [43] Ventilation and indoor air quality in office buildings
    Pan, YQ
    Long, WD
    Fan, CY
    INTERNATIONAL SYMPOSIUM ON AIR CONDITIONING IN HIGH RISE BUILDINGS '2000, PROCEEDINGS, 2000, 2000 (03): : 225 - 229
  • [44] The Effects of Ventilation on Indoor Air Quality in Schools
    Zhong, Lexuan
    2018 ASHRAE ANNUAL CONFERENCE, 2018,
  • [45] BUILDING VENTILATION AND INDOOR AIR-QUALITY
    BERK, JV
    AMERICAN CERAMIC SOCIETY BULLETIN, 1980, 59 (03): : 327 - 327
  • [46] Ventilation and Indoor Air Quality in Residential Bedrooms
    Fritz, Hagen
    Kinney, Kerry
    Schnyer, David
    Nagy, Zoltan
    ASHRAE TRANSACTIONS 2021, VOL 127, PT 2, 2021, 127 : 500 - 508
  • [47] Indoor air quality and the effects of displacement ventilation
    Fläkt Woods, Tufnell Way, Colchester CO4 5AR, United Kingdom
    Build. Eng., 2006, 1 (22-23):
  • [48] Ventilation strategies to improve indoor air quality
    Luo, Q
    Tang, G
    Huang, W
    INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 3313 - 3317
  • [49] Indoor Air Quality Monitoring Improving Air Quality Perception
    Herberger, Simone
    Ulmer, Heiko
    CLEAN-SOIL AIR WATER, 2012, 40 (06) : 578 - 585
  • [50] VENTILATION FOR ACCEPTABLE INDOOR AIR-QUALITY
    JANSSEN, JE
    ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1989, 31 (10): : 40 - &