Modeling the tensile behavior of the cement-bone interface using nonlinear fracture mechanics

被引:22
|
作者
Mann, KA
Werner, FW
Ayers, DC
机构
[1] Department of Orthopedic Surgery, S.U.N.Y. Health Science Center at Syracuse, Syracuse, NY
关键词
D O I
10.1115/1.2796077
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The tensile mechanical behavior of the cement-bone interface where there was a large process (plastic) zone at the interface was modeled using a nonlinear fracture mechanics approach. A finite element method was employed, which included a piecewise nonlinear interface, to investigate the behavior of experimental cement-bone test specimens and an idealized stem-cement-bone (SCB) structure. The interface model consisted of a. linear elastic region with high stiffness until the yield strength was reached, followed by an exponential softening region until Zero stress. The yield strength and rare of exponential softening after yielding at the cement-bone interface were shown to have a marked effect on the structural stiffness of the SCB model. The results indicate that both yield strength and postyield behavior should be included to characterize the mechanics of the cement-bone interface fully.
引用
收藏
页码:175 / 178
页数:4
相关论文
共 50 条
  • [41] Fracture mechanics analysis of the dentine-luting cement interface
    Ryan, AK
    Mitchell, CA
    Orr, JF
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2002, 216 (H4) : 271 - 276
  • [42] The use of complementary non-destructive evaluation methods to evaluate the integrity of the cement-bone interface
    Leung, S. Y.
    New, A. M.
    Browne, M.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2009, 223 (H1) : 75 - 86
  • [43] Bone quality, and the combination and penetration of cement-bone interface A comparative micro-CT study of osteoarthritis and rheumatoid arthritis
    Song, Yuanzheng
    Zhu, Fahao
    Lin, Feng
    Zhang, Feng
    Zhang, Shuaigong
    MEDICINE, 2018, 97 (35)
  • [44] Fatigue creep damage at the cement-bone interface: An experimental and a micro-mechanical finite element study
    Waanders, Daan
    Janssen, Dennis
    Miller, Mark A.
    Mann, Kenneth A.
    Verdonschot, Nico
    JOURNAL OF BIOMECHANICS, 2009, 42 (15) : 2513 - 2519
  • [45] Novel methods to study functional loading micromechanics at the stem-cement and cement-bone interface in cemented femoral hip replacements
    Race, A.
    Miller, M. A.
    Mann, K. A.
    JOURNAL OF BIOMECHANICS, 2010, 43 (04) : 788 - 791
  • [46] Microcracking and fracture behavior of cement grout under tensile loading
    Shams, Ghasem
    Moradian, Omid
    Li, Bing Q.
    Rivard, Patrice
    CONSTRUCTION AND BUILDING MATERIALS, 2025, 467
  • [47] SHEAR-STRENGTH OF TRABECULAR BONE FROM FEMUR, AND SOME FACTORS AFFECTING SHEAR-STRENGTH OF CEMENT-BONE INTERFACE
    HALAWA, M
    LEE, AJC
    LING, RSM
    VANGALA, SS
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1978, 92 (01) : 19 - 30
  • [48] The influence of different tibial stem designs in load sharing and stability at the cement-bone interface in revision TKA
    Completo, A.
    Simoes, J. A.
    Fonseca, F.
    Oliveira, M.
    KNEE, 2008, 15 (03): : 227 - 232
  • [49] Numerical modeling of tensile fracture initiation and propagation in snow slabs using nonlocal damage mechanics
    Borstad, C. P.
    McClung, D. M.
    COLD REGIONS SCIENCE AND TECHNOLOGY, 2011, 69 (2-3) : 145 - 155
  • [50] FRACTURE MECHANICS OF BONE, ANOTHER LOOK AT COMPOSITE MODELING
    COOKE, FW
    ZEIDMAN, H
    SCHEIFELE, SJ
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1973, 7 (03): : 383 - 399