Modeling the tensile behavior of the cement-bone interface using nonlinear fracture mechanics

被引:22
|
作者
Mann, KA
Werner, FW
Ayers, DC
机构
[1] Department of Orthopedic Surgery, S.U.N.Y. Health Science Center at Syracuse, Syracuse, NY
关键词
D O I
10.1115/1.2796077
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The tensile mechanical behavior of the cement-bone interface where there was a large process (plastic) zone at the interface was modeled using a nonlinear fracture mechanics approach. A finite element method was employed, which included a piecewise nonlinear interface, to investigate the behavior of experimental cement-bone test specimens and an idealized stem-cement-bone (SCB) structure. The interface model consisted of a. linear elastic region with high stiffness until the yield strength was reached, followed by an exponential softening region until Zero stress. The yield strength and rare of exponential softening after yielding at the cement-bone interface were shown to have a marked effect on the structural stiffness of the SCB model. The results indicate that both yield strength and postyield behavior should be included to characterize the mechanics of the cement-bone interface fully.
引用
收藏
页码:175 / 178
页数:4
相关论文
共 50 条
  • [21] Morphology based cohesive zone modeling of the cement-bone interface from postmortem retrievals
    Waanders, Daan
    Janssen, Dennis
    Mann, Kenneth A.
    Verdonschot, Nico
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2011, 4 (07) : 1492 - 1503
  • [22] The mechanical effects of different levels of cement penetration at the cement-bone interface
    Waanders, Daan
    Janssen, Dennis
    Mann, Kenneth A.
    Verdonschot, Nico
    JOURNAL OF BIOMECHANICS, 2010, 43 (06) : 1167 - 1175
  • [23] Mixed-mode failure response of the cement-bone interface
    Mann, KA
    Mocarski, R
    Damron, LA
    Allen, MJ
    Ayers, DC
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2001, 19 (06) : 1153 - 1161
  • [24] Residual stress effects on fracture energies of cement-bone and cement-implant interfaces
    Zor, M
    Küçük, M
    Aksoy, S
    BIOMATERIALS, 2002, 23 (07) : 1595 - 1601
  • [25] THE EFFECT OF BLEEDING ON THE CEMENT-BONE INTERFACE - AN EXPERIMENTAL-STUDY
    MAJKOWSKI, RS
    BANNISTER, GC
    MILES, AW
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1994, (299) : 293 - 297
  • [26] The Influence of Cement Morphology Parameters on the Strength of the Cement-Bone Interface in Tibial Tray Fixation
    Nagel, Katrin
    Bishop, Nicholas E.
    Schlegel, Ulf J.
    Pueschel, Klaus
    Morlock, Michael M.
    JOURNAL OF ARTHROPLASTY, 2017, 32 (02): : 563 - +
  • [27] RHEUMATOID NODULES AT THE CEMENT-BONE INTERFACE IN REVISION ARTHROPLASTY OF RHEUMATOID PATIENTS
    INOUE, K
    NISHIOKA, J
    HUKUDA, S
    SHICHIKAWA, K
    OKABE, H
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1993, 75 (03): : 455 - 458
  • [28] Mechanical strength of the cement-bone interface is greater in shear than in tension
    Mann, KA
    Werner, FW
    Ayers, DC
    JOURNAL OF BIOMECHANICS, 1999, 32 (11) : 1251 - 1254
  • [29] Assess the fracture energy of bone using nonlinear fracture mechanics.
    Yan, J.
    Taskonak, B.
    Mecholsky, J.
    JOURNAL OF BONE AND MINERAL RESEARCH, 2006, 21 : S270 - S270
  • [30] A RAT MODEL OF RESORPTION OF BONE AT THE CEMENT-BONE INTERFACE IN THE PRESENCE OF POLYETHYLENE WEAR PARTICLES
    HOWIE, DW
    VERNONROBERTS, B
    OAKESHOTT, R
    MANTHEY, B
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (02): : 257 - 263