A CFD-based test method for control of indoor environment in air-conditioned rooms

被引:0
|
作者
Li, Kangji [1 ,2 ]
Su, Hongye [1 ]
Chu, Jian [1 ]
机构
[1] Zhejiang Univ, Inst Cyber Syst & Control, Hangzhou 310027, Zhejiang, Peoples R China
[2] Jiangsu Univ, Sch Elect Informat Engn, Zhenjiang 212013, Peoples R China
基金
国家高技术研究发展计划(863计划);
关键词
CFD; single neuron; PID; system simulation; temperature control; TEMPERATURE DISTRIBUTION; MODEL; SIMULATION; SPACE;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Because of the complexity of the indoor dynamic thermal environment, several kinds of simplified surrogate models, such as zone model and proper orthogonal decomposition (POD) based reduced-order model, have been developed for fast simulation and control purpose. To test and calibrate the performance of such models, a computational fluid dynamics (CFD) based test method is presented in this paper. The proposed virtual test model combines a CFD-based air-conditioned room with a single neuron adaptive PID controller, which is programmed using the user-defined function and embedded in the CFD model. Additionally, a space temperature offset model is developed using least squares estimation (LSE). This offset model is used to compensate the temperature difference between actual sensor locations and occupied zones. Test studies not only show the great interoperation between the PID controller and the CFD simulation but also demonstrate the acceptable accuracy of the LSE-based temperature estimation.
引用
收藏
页码:6933 / 6937
页数:5
相关论文
共 50 条
  • [31] Thermal performance of envelope wall/roofs of intermittent air-conditioned rooms
    Barrios, G.
    Huelsz, G.
    Rojas, J.
    APPLIED THERMAL ENGINEERING, 2012, 40 : 1 - 7
  • [33] Study on Temperature Distribution with CFD Simulations of an Air-Conditioned Room
    Fang, Ping
    Liu, Tingzhang
    Liu, Kai
    Zhao, Jianfei
    THEORY, METHODOLOGY, TOOLS AND APPLICATIONS FOR MODELING AND SIMULATION OF COMPLEX SYSTEMS, PT III, 2016, 645 : 245 - 252
  • [34] A Dynamic Simulation of Indoor Polydispersion of Particles in All-Air Air-Conditioned Environment with Dynamical Particle Sources
    Li, Min
    Wu, Chun-Liang
    Sun, Liang-Liang
    Lai, Alvin C. K.
    INDOOR AND BUILT ENVIRONMENT, 2012, 21 (02) : 282 - 291
  • [35] Indoor suspended particulates distribution in an air-conditioned teaching building
    Huang, YC
    Yang, SH
    INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 1807 - 1810
  • [36] Indoor Environmental Quality Benchmarks for Air-conditioned Offices in the Subtropics
    Mui, K. W.
    Wong, L. T.
    Hui, P. S.
    INDOOR AND BUILT ENVIRONMENT, 2009, 18 (02) : 123 - 129
  • [37] Practices contributing to biotic pollution in Air-conditioned indoor environments
    Khan, A. A. Haleem
    Karuppayil, S. Mohan
    AEROBIOLOGIA, 2011, 27 (01) : 85 - 89
  • [38] Social and behavioral determinants of indoor temperatures in air-conditioned homes
    Wright, Mary K.
    Hondula, David M.
    Chakalian, Paul M.
    Kurtz, Liza C.
    Watkins, Lance
    Gronlund, Carina J.
    Larsen, Larissa
    Mallen, Evan
    Harlan, Sharon L.
    BUILDING AND ENVIRONMENT, 2020, 183
  • [39] CFD-driven optimization of air supplies deployment in an air-conditioned office
    Xu, George
    Xing, Xiuqing
    Vinh Tan Nguyen
    Poh, Hee Joo
    Lou, Jing
    4TH ASIA CONFERENCE OF INTERNATIONAL BUILDING PERFORMANCE SIMULATION ASSOCIATION, 2019, 238
  • [40] Practices contributing to biotic pollution in Air-conditioned indoor environments
    A. A. Haleem Khan
    S. Mohan Karuppayil
    Aerobiologia, 2011, 27 : 85 - 89