A CFD-based test method for control of indoor environment in air-conditioned rooms

被引:0
|
作者
Li, Kangji [1 ,2 ]
Su, Hongye [1 ]
Chu, Jian [1 ]
机构
[1] Zhejiang Univ, Inst Cyber Syst & Control, Hangzhou 310027, Zhejiang, Peoples R China
[2] Jiangsu Univ, Sch Elect Informat Engn, Zhenjiang 212013, Peoples R China
基金
国家高技术研究发展计划(863计划);
关键词
CFD; single neuron; PID; system simulation; temperature control; TEMPERATURE DISTRIBUTION; MODEL; SIMULATION; SPACE;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Because of the complexity of the indoor dynamic thermal environment, several kinds of simplified surrogate models, such as zone model and proper orthogonal decomposition (POD) based reduced-order model, have been developed for fast simulation and control purpose. To test and calibrate the performance of such models, a computational fluid dynamics (CFD) based test method is presented in this paper. The proposed virtual test model combines a CFD-based air-conditioned room with a single neuron adaptive PID controller, which is programmed using the user-defined function and embedded in the CFD model. Additionally, a space temperature offset model is developed using least squares estimation (LSE). This offset model is used to compensate the temperature difference between actual sensor locations and occupied zones. Test studies not only show the great interoperation between the PID controller and the CFD simulation but also demonstrate the acceptable accuracy of the LSE-based temperature estimation.
引用
收藏
页码:6933 / 6937
页数:5
相关论文
共 50 条
  • [21] Indoor air pollution in Air-Conditioned bus and non-Air-Conditioned bus
    Husna, I. E.
    Unzilatirrizqi, Y. E. R. D.
    Sarifuddin
    Wijinurhayati, A. A.
    2ND INTERNATIONAL CONFERENCE ON ENVIRONMENT, SUSTAINABILITY ISSUES, AND COMMUNITY DEVELOPMENT, 2021, 623
  • [22] Diagnostics of Unsatisfactory Indoor Air Quality in Air-Conditioned Workplaces
    Mui, K. W.
    Hui, P. S.
    Wong, L. T.
    INDOOR AND BUILT ENVIRONMENT, 2011, 20 (03) : 313 - 320
  • [23] Screening for indoor air quality of air-conditioned off ices
    Wong, L. T.
    Mui, K. W.
    Hui, P. S.
    INDOOR AND BUILT ENVIRONMENT, 2007, 16 (05) : 438 - 443
  • [24] INDOOR/OUTDOOR AIR POLLUTANT RELATIONSHIPS FOR AIR-CONDITIONED BUILDINGS
    YOCUM, JE
    COTE, WA
    ASHRAE JOURNAL, 1971, 13 (01): : 54 - &
  • [25] THE INTERNAL MODE FRACTIONAL-ORDER PID CONTROL BASED ON NEURAL NETWORK FOR THE TEMPERATURE OF AIR-CONDITIONED ROOMS
    Zhuang, Mengxiang
    Zhu, Qixin
    INTERNATIONAL JOURNAL OF INNOVATIVE COMPUTING INFORMATION AND CONTROL, 2021, 17 (03): : 1019 - 1028
  • [26] Fungi - an indoor air quality assessment parameter for air-conditioned offices
    Mui, K. W.
    Chan, W. Y.
    Wong, L. T.
    Hui, P. S.
    BUILDING SERVICES ENGINEERING RESEARCH & TECHNOLOGY, 2007, 28 (03): : 265 - 274
  • [27] Indoor Air Quality Related to Occupancy at an Air-conditioned Public Building
    Ponsoni, Karina
    Goncalves Raddi, Maria Stella
    BRAZILIAN ARCHIVES OF BIOLOGY AND TECHNOLOGY, 2010, 53 (01) : 99 - 103
  • [28] An epistemic indoor air quality assessment protocol for air-conditioned offices
    Hui, P. S.
    Wong, L. T.
    Mui, K. W.
    INDOOR AND BUILT ENVIRONMENT, 2007, 16 (02) : 139 - 147
  • [29] A survey of indoor air quality problems in air-conditioned buildings in India
    Kalaiselvam, S
    Robin, JR
    Jose, S
    Iniyan, S
    Samuel, AA
    INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 893 - 897
  • [30] AIR-CONDITIONED RIPENING AND STORAGE ROOMS FOR LONG-LIFE PRODUCTS
    KROGER, P
    FLEISCHWIRTSCHAFT, 1982, 62 (10): : 1286 - &