Conventional and advanced exergy analyses of an air-conditioning system in a subway station

被引:7
|
作者
Yin, Hua [1 ,2 ]
Guo, Huafang [1 ,2 ]
Tang, Zhihua [1 ,2 ]
Yu, Junyan [3 ]
Lu, Haiyang [4 ]
机构
[1] Chinese Acad Sci, Guangzhou Inst Energy Convers, Key Lab Renewable Energy, 2 Nengyuan Rd, Guangzhou 510640, Guangdong, Peoples R China
[2] Guangdong Key Lab New & Renewable Energy Res & De, 2 Nengyuan Rd, Guangzhou 510640, Guangdong, Peoples R China
[3] Guangzhou Metro Grp Co Ltd, Tower A,Wansheng Sq,1238 Xingang East Rd, Guangzhou 510330, Guangdong, Peoples R China
[4] Guangdong Univ Technol, Sch Automated Inst, Waihuan West Rd, Guangzhou 5100006, Guangdong, Peoples R China
关键词
conventional and advanced exergy analyses; air-conditioning system; subway station; CARBON-DIOXIDE; ENERGY; DESTRUCTIONS; OPTIMIZATION; PLANT; CYCLE; HVAC;
D O I
10.1504/IJEX.2019.100365
中图分类号
O414.1 [热力学];
学科分类号
摘要
Air-conditioning systems in subway stations consume a large amount of energy. In this study, conventional and advanced exergy analyses were carried out to determine the energy-saving potential of an air-conditioning system in a subway station. Results show that air handling unit (AHU) should be improved for the highest values of relative irreversibility (RI) with conventional exergy analysis, whereas the compressor should have the highest improvement priority for the largest avoidable exergy destruction with advanced exergy analysis. Moreover, influences of compressor efficiency, condensation temperature, and evaporation temperature on avoidable exergy destruction of the air-conditioning system were also investigated. According to the findings, compressor efficiency significantly influences the system's total avoidable exergy destruction. The lower the compressor efficiency, the more rapidly the avoidable exergy destruction of the compressor increases. Furthermore, the avoidable exergy destruction of condenser, compressor, cooling tower (CT), and cooling water pump (CWP) increases with the rise of the condensation temperature, whereas that of the evaporator, throttling valve (TV), condenser, compressor, CT, and CWP decreases with the rise of the evaporation temperature.
引用
收藏
页码:236 / 262
页数:27
相关论文
共 50 条
  • [31] PLANNING AN AIR-CONDITIONING SYSTEM
    BLIND, G
    BLIND, D
    VETERINARY ECONOMICS, 1978, 19 (07): : 24 - 26
  • [32] AIR-CONDITIONING - SYSTEM SIZING
    ABRAMS, DW
    SOLAR AGE, 1983, 8 (01): : 56 - 56
  • [33] CINEMA AIR-CONDITIONING SYSTEM
    不详
    REFRIGERATION AND AIR CONDITIONING, 1973, 76 (904): : 85 - &
  • [34] MOISTURE IN THE AIR-CONDITIONING SYSTEM
    不详
    NORSK SKOGINDUSTRI, 1979, 33 (12): : 318 - 318
  • [35] Numerical Analysis of Exergy for Air-Conditioning Influenced by Ambient Temperature
    Lee, Jing-Nang
    Chen, Chien-Chih
    Ting, Chen-Ching
    INTERNATIONAL JOURNAL OF ENGINEERING AND TECHNOLOGY INNOVATION, 2014, 4 (03) : 152 - 160
  • [36] Performance comparison of temperature and humidity independent control air-conditioning system with conventional system
    Zhang, Tao
    Liu, Xiao-Hua
    BUILDING SERVICES ENGINEERING RESEARCH & TECHNOLOGY, 2016, 37 (04): : 479 - 488
  • [37] Establishment and Analysis of Energy Consumption Prediction Model of Air Conditioning System in Subway Station
    Yu, Wenhong
    Yang, Shuo
    Wang, Haoyu
    Wang, Kuan
    2022 8TH INTERNATIONAL CONFERENCE ON HYDRAULIC AND CIVIL ENGINEERING: DEEP SPACE INTELLIGENT DEVELOPMENT AND UTILIZATION FORUM, ICHCE, 2022, : 427 - 430
  • [38] Study on Remote Monitoring System of Subway Central Air-conditioning Systems Based on Internet of Things
    Wang, Lingyun
    Zhang, Wei
    Xu, Linghong
    Ni, Peng
    PROCEEDINGS OF THE 2016 4TH INTERNATIONAL CONFERENCE ON SENSORS, MECHATRONICS AND AUTOMATION (ICSMA 2016), 2016, 136 : 627 - 632
  • [39] TECHNICAL AND HYGIENIC STUDIES IN OPERATING-ROOMS WITH CONVENTIONAL AIR-CONDITIONING SYSTEM
    JANSSEN, E
    JANSSEN, G
    ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 1975, 113 (04): : 816 - 817
  • [40] A feasibility study of using thermal energy storage in a conventional air-conditioning system
    Hussain, MM
    Dincer, I
    Zubair, SM
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2004, 28 (11) : 955 - 967