Assessment of shunt volumes in children with ventricular septal defects: comparative quantification of MR flow measurements and invasive oximetry

被引:12
|
作者
Esmaeili, A.
Hoehn, R.
Koch, A.
Vogl, T. J.
Hofstetter, R.
Abolmaali, N.
机构
[1] Carl Gustav Carus Tech Univ, Fac Med, D-01307 Dresden, Germany
[2] Goethe Univ Frankfurt, Dept Pediat Cardiol, D-6000 Frankfurt, Germany
[3] Goethe Univ Frankfurt, Inst Diagnost & Intervent Radiol, Frankfurt, Germany
关键词
ventricular septal defects; left-to-right shunt; shunt measurement; magnetic resonance flow measurement; heart catheterization; children;
D O I
10.1007/s00392-006-0415-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The aim of this study was to compare the results of magnetic resonance based shunt volume measurements with the results of the invasive method by the principle of Fick. In 14 children (median age: 16.5 months) with ventricular septal defects the shunt volume was quantified by magnetic resonance flow measurements under spontaneous breathing conditions as well as with invasive angiography during one sedation. A good correlation between both methods was observed (r(2)= 0.8, p < 0.0001, CI95% = 0.62-1.22). A tendency towards higher values in the noninvasive technique was found in the Bland-Altman plot (bias = 3.79). Magnetic resonance based shunt measurements are a reliable alternative to the invasive shunt measurement by cardiac catheterization.
引用
收藏
页码:523 / 530
页数:8
相关论文
共 50 条
  • [41] Minimally invasive transthoracic device closure of ventricular septal defects in younger and low body weight children: clinical experience and mid-term results
    Xing, Quansheng
    CARDIOLOGY, 2011, 120 : 105 - 106
  • [42] QUANTIFICATION OF SHUNT VOLUME THROUGH VENTRICULAR SEPTAL DEFECTS OF VARIED AREA, SHAPE AND NUMBER USING REAL-TIME 3D COLOR DOPPLER ECHOCARDIOGRAPHY: AN IN VITRO STUDY
    Sahn, David J.
    Tracy, Evan
    Dang, Kim
    Joanne Tran
    Zhu, Meihua
    Ashraf, Muhammad
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 67 (13) : 1797 - 1797
  • [43] Maternal serum CFHR4 protein as a potential non-invasive marker of ventricular septal defects in offspring: evidence from a comparative proteomics study
    Jing He
    Liang Xie
    Li Yu
    Lijun Liu
    Hong Xu
    Tao Wang
    Yuyang Gao
    Xuedong Wang
    You Duan
    Hanmin Liu
    Li Dai
    Clinical Proteomics, 2022, 19
  • [44] Maternal serum CFHR4 protein as a potential non-invasive marker of ventricular septal defects in offspring: evidence from a comparative proteomics study
    He, Jing
    Xie, Liang
    Yu, Li
    Liu, Lijun
    Xu, Hong
    Wang, Tao
    Gao, Yuyang
    Wang, Xuedong
    Duan, You
    Liu, Hanmin
    Dai, Li
    CLINICAL PROTEOMICS, 2022, 19 (01)
  • [45] Noninvasive assessment of left-to-right shunting in ventricular septal defects by the proximal isovelocity surface area method on Doppler colour flow mapping
    Kosecik, Mustafa
    Sagin-Saylam, Gul
    Unal, Nurettin
    Kir, Mustafa
    Paytoncu, Sebnem
    CANADIAN JOURNAL OF CARDIOLOGY, 2007, 23 (13) : 1049 - 1053
  • [46] APPLICABILITY OF THERMODILUTION METHOD FOR DETERMINATION OF PULMONARY BLOOD-FLOW AND PULMONARY VASCULAR-RESISTANCE IN INFANTS AND CHILDREN WITH VENTRICULAR SEPTAL-DEFECTS
    HEDVALL, G
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1978, 38 (06): : 581 - 585
  • [47] Non-invasive automated assessment of the ratio of pulmonary to systemic flow in patients with atrial septal defects by the colour Doppler velocity profile integration method
    Ueda, Y
    Hozumi, T
    Yoshida, K
    Watanabe, H
    Akasaka, T
    Takagi, T
    Yamamuro, A
    Homma, S
    Yoshikawa, J
    HEART, 2002, 88 (03) : 278 - 282
  • [48] Transcatheter closure, mini-invasive closure and open-heart surgical repair for treatment of perimembranous ventricular septal defects in children: a protocol for a network meta-analysis
    You, Tao
    Yi, Kang
    Ding, Zhao-hong
    Hou, Xiao-dong
    Liu, Xing-guang
    Wang, Xin-kuan
    Ge, Long
    Tian, Jin-hui
    BMJ OPEN, 2017, 7 (06):
  • [49] Quantification of the area and shunt volume of multiple, circular, and noncircular ventricular septal defects: A 2D/3D echocardiography comparison and real time 3D color Doppler feasibility determination study
    Tracy, Evan
    Zhu, Meihua
    Streiff, Cole
    Sahn, David J.
    Ashraf, Muhammad
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2018, 35 (01): : 90 - 99
  • [50] Short axis versus axial Cine SSFP MR imaging for assessment of right and left ventricular function: intrapatient correlation with phase-contrast flow measurements
    Susan H James
    Rachel Wald
    Bernd J Wintersperger
    Laura Jimenez-Juan
    Djeven Deva
    Andrew Crean
    Elsie Nguyen
    Narinder Paul
    Sebastian Ley
    Journal of Cardiovascular Magnetic Resonance, 13 (Suppl 1)