Assessment of shunt volumes in children with ventricular septal defects: comparative quantification of MR flow measurements and invasive oximetry

被引:12
|
作者
Esmaeili, A.
Hoehn, R.
Koch, A.
Vogl, T. J.
Hofstetter, R.
Abolmaali, N.
机构
[1] Carl Gustav Carus Tech Univ, Fac Med, D-01307 Dresden, Germany
[2] Goethe Univ Frankfurt, Dept Pediat Cardiol, D-6000 Frankfurt, Germany
[3] Goethe Univ Frankfurt, Inst Diagnost & Intervent Radiol, Frankfurt, Germany
关键词
ventricular septal defects; left-to-right shunt; shunt measurement; magnetic resonance flow measurement; heart catheterization; children;
D O I
10.1007/s00392-006-0415-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The aim of this study was to compare the results of magnetic resonance based shunt volume measurements with the results of the invasive method by the principle of Fick. In 14 children (median age: 16.5 months) with ventricular septal defects the shunt volume was quantified by magnetic resonance flow measurements under spontaneous breathing conditions as well as with invasive angiography during one sedation. A good correlation between both methods was observed (r(2)= 0.8, p < 0.0001, CI95% = 0.62-1.22). A tendency towards higher values in the noninvasive technique was found in the Bland-Altman plot (bias = 3.79). Magnetic resonance based shunt measurements are a reliable alternative to the invasive shunt measurement by cardiac catheterization.
引用
收藏
页码:523 / 530
页数:8
相关论文
共 50 条
  • [31] Noninvasive quantification of left-to-right shunt by phase contrast magnetic resonance imaging in secundum atrial septal defect: the effects of breath holding and comparison with invasive oximetry
    Yuzo Yamasaki
    Satoshi Kawanami
    Takeshi Kamitani
    Koji Sagiyama
    Ichiro Sakamoto
    Ken-ichi Hiasa
    Hidetake Yabuuchi
    Michinobu Nagao
    Hiroshi Honda
    The International Journal of Cardiovascular Imaging, 2018, 34 : 931 - 937
  • [32] Evaluation of atrial septal defects with 4D flow MRI—multilevel and inter-reader reproducibility for quantification of shunt severity
    Raluca G. Chelu
    Michael Horowitz
    Dominica Sucha
    Isabella Kardys
    Delphine Ingremeau
    Shreyas Vasanawala
    Koen Nieman
    Jean-Francois Paul
    Albert Hsiao
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2019, 32 : 269 - 279
  • [33] THE USEFULNESS OF CROSS-SECTIONAL DOPPLER FLOW IMAGING IN THE DETECTION OF SMALL VENTRICULAR SEPTAL-DEFECTS WITH LEFT-TO-RIGHT SHUNT
    KAPUSTA, L
    HOPMAN, JCW
    DANIELS, O
    EUROPEAN HEART JOURNAL, 1987, 8 (09) : 1002 - 1006
  • [34] THE EFFECT OF EXERCISE ON PULMONARY BLOOD FLOW AND ON LEFT-TO-RIGHT SHUNT IN PATIENTS WITH VENTRICULAR SEPTAL DEFECTS AND NORMAL PULMONARY ARTERIAL PRESSURES
    THEILEN, EO
    SASAKI, R
    FISHER, JM
    WILSON, WR
    JOURNAL OF LABORATORY AND CLINICAL MEDICINE, 1960, 55 (05): : 689 - 693
  • [35] Transesophageal Echocardiography Detection of Undiagnosed Multiple Muscular Ventricular Septal Defects with Alteration of Shunt Flow by Right Ventricular Pacing After an Arterial Switch Operation in a Neonate
    Kurokawa, Satoshi
    Taneoka, Miki
    Imai, Hidekazu
    Baba, Hiroshi
    Nomura, Minoru
    ANESTHESIA AND ANALGESIA, 2011, 113 (02): : 233 - 235
  • [36] Validation of the accuracy of both right and left ventricular outflow volume determinations and semiautomated calculation of shunt volumes through atrial septal defects by digital color Doppler flow mapping in a chronic animal model
    Shiota, T
    Jones, M
    Aida, S
    Chikada, M
    Tsujino, H
    El-Kadi, T
    Sahn, DJ
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1999, 34 (02) : 587 - 593
  • [37] MR CSF Flow Examination as a Non-Invasive Method of Determining Shunt-Independent Hydrocephalus in Children with Implanted Ventriculoperitoneal Shunt Preliminary Results
    Szafirska, M.
    Urbanik, A.
    Herman-Sucharska, I.
    Kwiatkowski, S.
    Swierczyna, A.
    NEURORADIOLOGY JOURNAL, 2008, 21 (02): : 212 - 218
  • [38] Quantitative assessment of ventricular septal defect shunt flow by three-dimensional reconstruction of color Doppler imaged vena contracta and flow convergence region
    Ishii, M
    Eto, G
    Tsutsumi, T
    Kato, H
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (02) : 298A - 298A
  • [39] Influence of high-flow modified ultrafiltration on brain oxygenation and perfusion during surgery for children with ventricular septal defects: a pilot study
    Jia, Zaishen
    Teng, Yichao
    Liu, Yuan
    Wang, Hong
    Li, Yue
    Hou, Xiaotong
    PERFUSION-UK, 2018, 33 (03): : 203 - 208
  • [40] USEFULNESS OF ECHOCARDIOGRAPHIC ASSESSMENT OF RIGHT VENTRICULAR AND PULMONARY TRUNK SIZE FOR ESTIMATING MAGNITUDE OF LEFT-TO-RIGHT SHUNT IN CHILDREN WITH ATRIAL SEPTAL-DEFECT
    DENEF, B
    DUMOULIN, M
    VANDERHAUWAERT, LG
    AMERICAN JOURNAL OF CARDIOLOGY, 1985, 55 (13): : 1571 - 1575