Assessment of shunt volumes in children with ventricular septal defects: comparative quantification of MR flow measurements and invasive oximetry

被引:12
|
作者
Esmaeili, A.
Hoehn, R.
Koch, A.
Vogl, T. J.
Hofstetter, R.
Abolmaali, N.
机构
[1] Carl Gustav Carus Tech Univ, Fac Med, D-01307 Dresden, Germany
[2] Goethe Univ Frankfurt, Dept Pediat Cardiol, D-6000 Frankfurt, Germany
[3] Goethe Univ Frankfurt, Inst Diagnost & Intervent Radiol, Frankfurt, Germany
关键词
ventricular septal defects; left-to-right shunt; shunt measurement; magnetic resonance flow measurement; heart catheterization; children;
D O I
10.1007/s00392-006-0415-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The aim of this study was to compare the results of magnetic resonance based shunt volume measurements with the results of the invasive method by the principle of Fick. In 14 children (median age: 16.5 months) with ventricular septal defects the shunt volume was quantified by magnetic resonance flow measurements under spontaneous breathing conditions as well as with invasive angiography during one sedation. A good correlation between both methods was observed (r(2)= 0.8, p < 0.0001, CI95% = 0.62-1.22). A tendency towards higher values in the noninvasive technique was found in the Bland-Altman plot (bias = 3.79). Magnetic resonance based shunt measurements are a reliable alternative to the invasive shunt measurement by cardiac catheterization.
引用
收藏
页码:523 / 530
页数:8
相关论文
共 50 条
  • [1] Assessment of shunt volumes in children with ventricular septal defects:comparative quantification of MR flow measurements and invasive oximetry
    Anoosh Esmaeili
    Rene Höhn
    Arne Koch
    Thomas Josef Vogl
    Roland Hofstetter
    Nasreddin Abolmaali
    Clinical Research in Cardiology, 2006, 95 : 523 - 530
  • [2] Flow quantification of intracardial shunt volumes using a MR phase contrast technique in breathhold in comparison with oximetry
    Petersen, SE
    Voigtlaender, T
    Wittlinger, T
    Kalden, P
    Scharhag, J
    Becker, D
    Kreitner, KF
    Thelen, M
    CIRCULATION, 1999, 100 (18) : 456 - 457
  • [3] Quantification of shunt fraction in ventricular septal defects of adults using an automated color Doppler method for flow volume evaluation
    Dennig, K
    Haase, UH
    Schömig, A
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (02) : 440A - 440A
  • [4] DOPPLER COLOR FLOW MAPPING ASSESSMENT OF RESIDUAL SHUNT AFTER CLOSURE OF LARGE VENTRICULAR SEPTAL-DEFECTS
    RYCHIK, J
    NORWOOD, WI
    CHIN, AJ
    CIRCULATION, 1990, 82 (04) : 77 - 77
  • [5] VENTRICULAR SEPTAL-DEFECT - VISUALIZATION OF SHUNT FLOW AND DETERMINATION OF SHUNT SIZE BY CINE MR IMAGING
    SECHTEM, U
    PFLUGFELDER, P
    CASSIDY, MC
    HOLT, W
    WOLFE, C
    HIGGINS, CB
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1987, 149 (04) : 689 - 692
  • [6] DOPPLER COLOR FLOW MAPPING ASSESSMENT OF RESIDUAL SHUNT AFTER CLOSURE OF LARGE VENTRICULAR SEPTAL-DEFECTS
    RYCHIK, J
    NORWOOD, WI
    CHIN, AJ
    CIRCULATION, 1991, 84 (05) : 153 - 161
  • [7] Non-invasive estimation of shunt volumes in patients with cardiac septum defects using MR imaging
    Roberts, HC
    Voigtlaender, T
    Roberts, TP
    Kreitner, KF
    Frick, C
    Thelen, M
    RADIOLOGY, 1997, 205 : 1016 - 1016
  • [8] Quantification of shunt volumes in congenital heart diseases using a breath-hold MR phase contrast technique -: comparison with oximetry
    Petersen, SE
    Voigtländer, T
    Kreitner, KF
    Kalden, P
    Wittlinger, T
    Scharhag, J
    Horstick, G
    Becker, D
    Hommel, G
    Thelen, M
    Meyer, J
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2002, 18 (01): : 53 - 60
  • [9] Quantification of shunt volumes in congenital heart diseases using a breath-hold MR phase contrast technique – comparison with oximetry
    Steffen E. Petersen
    Thomas Voigtländer
    Karl-Friedrich Kreitner
    Peter Kalden
    Thomas Wittlinger
    Jürgen Scharhag
    Georg Horstick
    Dietmar Becker
    Gerhard Hommel
    Manfred Thelen
    Jürgen Meyer
    The International Journal of Cardiovascular Imaging, 2002, 18 : 53 - 60
  • [10] Comparison between biventricular cine MRI and MR flow quantification in ascending aorta and pulmonary outflow tract for the assessment of intracardial shunt volumes
    Rominger, MB
    Kluge, A
    Dinkel, HP
    Bachmann, GF
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2002, 174 (11): : 1380 - 1386