Wear Compliance and Activity in Children Wearing Wrist- and Hip-Mounted Accelerometers

被引:206
|
作者
Fairclough, Stuart J. [1 ,2 ]
Noonan, Robert [3 ]
Rowlands, Alex V. [4 ,5 ]
Van Hees, Vincent [6 ]
Knowles, Zoe [3 ]
Boddy, Lynne M.
机构
[1] Edge Hill Univ, Dept Sport & Phys Act, Ormskirk L39 4QP, Lancs, England
[2] Univ Limerick, Dept Phys Educ & Sport Sci, Limerick, Ireland
[3] Liverpool John Moores Univ, Res Inst Sport & Exercise Sci, Phys Act Exchange, Liverpool L3 5UX, Merseyside, England
[4] Univ Leicester, Leicester Gen Hosp, Diabet Res Ctr, Leicester, Leics, England
[5] Natl Inst Hlth Res, Leicester Loughborough Diet Lifestyle & Phys Act, Leicester, Leics, England
[6] Newcastle Univ, Inst Cellular Med, MoveLab, Phys Act & Exercise Res, Newcastle Upon Tyne NE1 7RU, Tyne & Wear, England
来源
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE | 2016年 / 48卷 / 02期
关键词
RAW ACCELERATIONS; WEAR TIME; PHYSICAL ACTIVITY; GENEACTIV; ACTIGRAPH GT3X+; PHYSICAL-ACTIVITY MONITORS; RAW ACCELERATION; CALIBRATION; COMPARABILITY; OUTPUT;
D O I
10.1249/MSS.0000000000000771
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Purpose: This study aimed to 1) explore children's compliance to wearing wrist-and hip-mounted accelerometers, 2) compare children's physical activity (PA) derived from raw accelerations of wrist and hip, and 3) examine differences in raw and counts PA measured by hip-worn accelerometry. Methods: One hundred and twenty-nine 9- to 10-yr-old children wore a wrist-mounted GENEActiv accelerometer (GAwrist) and a hip-mounted ActiGraph GT3X+ accelerometer (AGhip) for 7 d. Both devices measured raw accelerations, and the AGhip also provided count-based data. Results: More children wore the GAwrist than those from the AGhip regardless of wear time criteria applied (P < 0.001-0.035). Raw data signal vector magnitude (r = 0.68), moderate PA (MPA) (r = 0.81), vigorous PA (VPA) (r = 0.85), and moderate-to-vigorous PA (MVPA) (r = 0.83) were strongly associated between devices (P < 0.001). GAwrist signal vector magnitude (P = 0.001), MPA (P = 0.037), VPA (P = 0.002), and MVPA (P = 0.016) were significantly greater than those from the AGhip. According to GAwrist raw data, 86.9% of children engaged in at least 60 min.d(-1) of MVPA, compared with 19% for AGhip. ActiGraph MPA (raw) was 42.00 +/- 1.61 min.d(-1) compared with 35.05 +/- 0.99 min.d(-1) (counts) (P = 0.02). ActiGraph VPA was 7.59 +/- 0.46 min.d(-1) (raw) and 37.06 +/- 1.85 min.d(-1) (counts; P = 0.19). Conclusions: In children, accelerometer wrist placement promotes superior compliance than the hip. Raw accelerations were significantly higher for GAwrist compared with those for AGhip possibly because of placement location and technical differences between devices. AGhip PA calculated from raw accelerations and counts differed substantially, demonstrating that PA outcomes derived from cut points for raw output and counts cannot be directly compared.
引用
收藏
页码:245 / 253
页数:9
相关论文
共 48 条
  • [31] Associations between appetite, physical activity and sedentary behaviour from hip- and wrist-worn accelerometers in older adults
    Tsai, Li-Tang
    Boyle, Eleanor
    Buhl, Sussi F.
    Kock, Gry
    Brond, Jan C.
    Visser, Marjolein
    Mendonca, Nuno
    Shiroma, Eric J.
    Caserotti, Paolo
    GERIATRICS & GERONTOLOGY INTERNATIONAL, 2023, 23 (06) : 411 - 417
  • [32] Moderate and Vigorous Physical Activity Intensity Cut-Points for Hip-, Wrist-, Thigh-, and Lower Back Worn Accelerometer in Very Old Adults
    Skjodt, Mathias
    Brond, Jan Christian
    Tully, Mark A.
    Tsai, Li-Tang
    Koster, Annemarie
    Visser, Marjolein
    Caserotti, Paolo
    SCANDINAVIAN JOURNAL OF MEDICINE & SCIENCE IN SPORTS, 2025, 35 (01)
  • [33] Sensor-Enabled Activity Recognition in Preschool Children: Hip versus Wrist Data
    Trost, Stewart G.
    Cliff, Dylan
    Hagenbuchner, Marcus
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2016, 48 (05): : 313 - 313
  • [34] Accelerometers-Embedded Lycra Sleeves to Test Wear Compliance and Upper-Limb Activity in People with Stroke: A Feasibility Study
    Kumar, Praveen
    Leake, Jason
    Brodie, Shannon
    Molton, Jennifer
    O'Reilly, Rosie
    Pearce, Alex
    Steele, Jade
    Caleb-Solly, Praminda
    JOURNAL OF PROSTHETICS AND ORTHOTICS, 2023, 35 (02) : 122 - 128
  • [35] Measuring Upper Extremity Activity of Children With Unilateral Cerebral Palsy Using Wrist-Worn Accelerometers: A Pilot Study
    Srinivasan, Sudha
    Amonkar, Nidhi
    Kumavor, Patrick D.
    Bubela, Deborah
    AMERICAN JOURNAL OF OCCUPATIONAL THERAPY, 2024, 78 (02):
  • [36] Validity of hip-mounted uniaxial accelerometry with heart-rate monitoring vs. triaxial accelerometry in the assessment of free-living energy expenditure in young children: the IDEFICS Validation Study
    Ojiambo, Robert
    Konstabel, Kenn
    Veidebaum, Toomas
    Reilly, John
    Verbestel, Vera
    Huybrechts, Inge
    Sioen, Isabelle
    Casajus, Jose A.
    Moreno, Luis A.
    Vicente-Rodriguez, German
    Bammann, Karin
    Tubic, Bojan M.
    Marild, Staffan
    Westerterp, Klaas
    Pitsiladis, Yannis P.
    JOURNAL OF APPLIED PHYSIOLOGY, 2012, 113 (10) : 1530 - 1536
  • [37] Measuring ambulation with wrist-based and hip-based activity trackers for children with cerebral palsy
    Sala, Debra A.
    Grissom, Helyn E.
    Delsole, Edward M.
    Chu, Mary Lynn
    Godfried, David H.
    Bhattacharyya, Surjya
    Karamitopoulos, Mara S.
    Chu, Alice
    DEVELOPMENTAL MEDICINE AND CHILD NEUROLOGY, 2019, 61 (11): : 1309 - +
  • [38] Comparison of physical activity metrics from two research-grade accelerometers worn on the non-dominant wrist and thigh in children
    Buchan, Duncan S.
    Maylor, Benjamin D.
    JOURNAL OF SPORTS SCIENCES, 2023, 41 (01) : 80 - 88
  • [39] ActiGraph GT3X+and Actical Wrist and Hip Worn Accelerometers for Sleep and Wake Indices in Young Children Using an Automated Algorithm: Validation With Polysomnography
    Smith, Claire
    Galland, Barbara
    Taylor, Rachael
    Meredith-Jones, Kim
    FRONTIERS IN PSYCHIATRY, 2020, 10
  • [40] Behaviour-based movement cut-off points in 3-year old children comparing wrist- with hip-worn actigraphs MW8 and GT3X
    Jansson, Daniel
    Westlander, Rikard
    Sandlund, Jonas
    West, Christina E.
    Domellof, Magnus
    Wulff, Katharina
    PLOS ONE, 2025, 20 (03):