Wear Compliance and Activity in Children Wearing Wrist- and Hip-Mounted Accelerometers

被引:206
|
作者
Fairclough, Stuart J. [1 ,2 ]
Noonan, Robert [3 ]
Rowlands, Alex V. [4 ,5 ]
Van Hees, Vincent [6 ]
Knowles, Zoe [3 ]
Boddy, Lynne M.
机构
[1] Edge Hill Univ, Dept Sport & Phys Act, Ormskirk L39 4QP, Lancs, England
[2] Univ Limerick, Dept Phys Educ & Sport Sci, Limerick, Ireland
[3] Liverpool John Moores Univ, Res Inst Sport & Exercise Sci, Phys Act Exchange, Liverpool L3 5UX, Merseyside, England
[4] Univ Leicester, Leicester Gen Hosp, Diabet Res Ctr, Leicester, Leics, England
[5] Natl Inst Hlth Res, Leicester Loughborough Diet Lifestyle & Phys Act, Leicester, Leics, England
[6] Newcastle Univ, Inst Cellular Med, MoveLab, Phys Act & Exercise Res, Newcastle Upon Tyne NE1 7RU, Tyne & Wear, England
来源
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE | 2016年 / 48卷 / 02期
关键词
RAW ACCELERATIONS; WEAR TIME; PHYSICAL ACTIVITY; GENEACTIV; ACTIGRAPH GT3X+; PHYSICAL-ACTIVITY MONITORS; RAW ACCELERATION; CALIBRATION; COMPARABILITY; OUTPUT;
D O I
10.1249/MSS.0000000000000771
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Purpose: This study aimed to 1) explore children's compliance to wearing wrist-and hip-mounted accelerometers, 2) compare children's physical activity (PA) derived from raw accelerations of wrist and hip, and 3) examine differences in raw and counts PA measured by hip-worn accelerometry. Methods: One hundred and twenty-nine 9- to 10-yr-old children wore a wrist-mounted GENEActiv accelerometer (GAwrist) and a hip-mounted ActiGraph GT3X+ accelerometer (AGhip) for 7 d. Both devices measured raw accelerations, and the AGhip also provided count-based data. Results: More children wore the GAwrist than those from the AGhip regardless of wear time criteria applied (P < 0.001-0.035). Raw data signal vector magnitude (r = 0.68), moderate PA (MPA) (r = 0.81), vigorous PA (VPA) (r = 0.85), and moderate-to-vigorous PA (MVPA) (r = 0.83) were strongly associated between devices (P < 0.001). GAwrist signal vector magnitude (P = 0.001), MPA (P = 0.037), VPA (P = 0.002), and MVPA (P = 0.016) were significantly greater than those from the AGhip. According to GAwrist raw data, 86.9% of children engaged in at least 60 min.d(-1) of MVPA, compared with 19% for AGhip. ActiGraph MPA (raw) was 42.00 +/- 1.61 min.d(-1) compared with 35.05 +/- 0.99 min.d(-1) (counts) (P = 0.02). ActiGraph VPA was 7.59 +/- 0.46 min.d(-1) (raw) and 37.06 +/- 1.85 min.d(-1) (counts; P = 0.19). Conclusions: In children, accelerometer wrist placement promotes superior compliance than the hip. Raw accelerations were significantly higher for GAwrist compared with those for AGhip possibly because of placement location and technical differences between devices. AGhip PA calculated from raw accelerations and counts differed substantially, demonstrating that PA outcomes derived from cut points for raw output and counts cannot be directly compared.
引用
收藏
页码:245 / 253
页数:9
相关论文
共 48 条
  • [11] Evaluating Compliance of Grade School-Aged Children To Wear Accelerometers
    Abbey, Bryce M.
    Heelan, Kate A.
    Welk, Greg
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2006, 38 (05): : S565 - S565
  • [12] Calibration and Validation of a Wrist- and Hip-Worn Actigraph Accelerometer in 4-Year-Old Children
    Johansson, Elin
    Larisch, Lisa-Marie
    Marcus, Claude
    Hagstromer, Maria
    PLOS ONE, 2016, 11 (09):
  • [13] "PAW PATROL IS ON A ROLL!" DECORATED WRIST-WORN ACCELEROMETERS HAVE HIGHER WEAR COMPLIANCE IN PRESCHOOLERS
    Parker, Hannah
    Burkart, Sarah
    Reesor-Oyer, Layton
    Dugger, Roddrick
    von Klinggraeff, Lauren E.
    White, James
    Pfledderer, Chris
    Glenn Weaver, R.
    Beets, Michael
    Armstrong, Bridget
    ANNALS OF BEHAVIORAL MEDICINE, 2022, 56 (SUPP 1) : S35 - S35
  • [14] Comparison of physical activity assessed using hip- and wrist-worn accelerometers
    Kamada, Masamitsu
    Shiroma, Eric J.
    Harris, Tamara B.
    Lee, I-Min
    GAIT & POSTURE, 2016, 44 : 23 - 28
  • [15] Daily physical activity patterns from hip- and wrist-worn accelerometers
    Shiroma, E. J.
    Schepps, M. A.
    Harezlak, J.
    Chen, K. Y.
    Matthews, C. E.
    Koster, A.
    Caserotti, P.
    Glynn, N. W.
    Harris, T. B.
    PHYSIOLOGICAL MEASUREMENT, 2016, 37 (10) : 1852 - 1861
  • [16] A Comparison of Wrist- Versus Hip-Worn ActiGraph Sensors for Assessing Physical Activity in Adults: A Systematic Review
    Gall, Nolan
    Sun, Ruopeng
    Smuck, Matthew
    JOURNAL FOR THE MEASUREMENT OF PHYSICAL BEHAVIOUR, 2022, 5 (04) : 252 - 262
  • [17] Comparing Hip, Wrist and Ankle-Worn ActiGraph Accelerometers for Measuring Physical Activity in Toddlers
    Wang, Tze-Hsuan
    Helmi, Ameer
    Mayoral, Rafael Morales
    Yao, Lucas
    Murray, April
    Fitter, Naomi T.
    Logan, Samuel W.
    CHILD CARE HEALTH AND DEVELOPMENT, 2025, 51 (03)
  • [18] Recognition of Elementary Upper Limb Movements in an Activity of Daily Living using Data from Wrist Mounted Accelerometers
    Biswas, Dwaipayan
    Cranny, Andy
    Gupta, Nayaab
    Maharatna, Koushik
    Ortmann, Steffen
    2014 IEEE INTERNATIONAL CONFERENCE ON HEALTHCARE INFORMATICS (ICHI), 2014, : 232 - 237
  • [19] Comparison of Compliance and Intervention Outcomes Between Hip- and Wrist-Worn Accelerometers During a Randomized Crossover Trial of an Active Video Games Intervention in Children
    Howie, Erin K.
    McVeigh, Joanne A.
    Straker, Leon M.
    JOURNAL OF PHYSICAL ACTIVITY & HEALTH, 2016, 13 (09): : 964 - 969
  • [20] Effect of sampling rate on acceleration and counts of hip- and wrist-worn ActiGraph accelerometers in children
    Clevenger, Kimberly A.
    Pfeiffer, Karin A.
    Mackintosh, Kelly A.
    McNarry, Melitta A.
    Brond, Jan
    Arvidsson, Daniel
    Montoye, Alexander H. K.
    PHYSIOLOGICAL MEASUREMENT, 2019, 40 (09)