Wear Compliance and Activity in Children Wearing Wrist- and Hip-Mounted Accelerometers

被引:206
|
作者
Fairclough, Stuart J. [1 ,2 ]
Noonan, Robert [3 ]
Rowlands, Alex V. [4 ,5 ]
Van Hees, Vincent [6 ]
Knowles, Zoe [3 ]
Boddy, Lynne M.
机构
[1] Edge Hill Univ, Dept Sport & Phys Act, Ormskirk L39 4QP, Lancs, England
[2] Univ Limerick, Dept Phys Educ & Sport Sci, Limerick, Ireland
[3] Liverpool John Moores Univ, Res Inst Sport & Exercise Sci, Phys Act Exchange, Liverpool L3 5UX, Merseyside, England
[4] Univ Leicester, Leicester Gen Hosp, Diabet Res Ctr, Leicester, Leics, England
[5] Natl Inst Hlth Res, Leicester Loughborough Diet Lifestyle & Phys Act, Leicester, Leics, England
[6] Newcastle Univ, Inst Cellular Med, MoveLab, Phys Act & Exercise Res, Newcastle Upon Tyne NE1 7RU, Tyne & Wear, England
来源
关键词
RAW ACCELERATIONS; WEAR TIME; PHYSICAL ACTIVITY; GENEACTIV; ACTIGRAPH GT3X+; PHYSICAL-ACTIVITY MONITORS; RAW ACCELERATION; CALIBRATION; COMPARABILITY; OUTPUT;
D O I
10.1249/MSS.0000000000000771
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Purpose: This study aimed to 1) explore children's compliance to wearing wrist-and hip-mounted accelerometers, 2) compare children's physical activity (PA) derived from raw accelerations of wrist and hip, and 3) examine differences in raw and counts PA measured by hip-worn accelerometry. Methods: One hundred and twenty-nine 9- to 10-yr-old children wore a wrist-mounted GENEActiv accelerometer (GAwrist) and a hip-mounted ActiGraph GT3X+ accelerometer (AGhip) for 7 d. Both devices measured raw accelerations, and the AGhip also provided count-based data. Results: More children wore the GAwrist than those from the AGhip regardless of wear time criteria applied (P < 0.001-0.035). Raw data signal vector magnitude (r = 0.68), moderate PA (MPA) (r = 0.81), vigorous PA (VPA) (r = 0.85), and moderate-to-vigorous PA (MVPA) (r = 0.83) were strongly associated between devices (P < 0.001). GAwrist signal vector magnitude (P = 0.001), MPA (P = 0.037), VPA (P = 0.002), and MVPA (P = 0.016) were significantly greater than those from the AGhip. According to GAwrist raw data, 86.9% of children engaged in at least 60 min.d(-1) of MVPA, compared with 19% for AGhip. ActiGraph MPA (raw) was 42.00 +/- 1.61 min.d(-1) compared with 35.05 +/- 0.99 min.d(-1) (counts) (P = 0.02). ActiGraph VPA was 7.59 +/- 0.46 min.d(-1) (raw) and 37.06 +/- 1.85 min.d(-1) (counts; P = 0.19). Conclusions: In children, accelerometer wrist placement promotes superior compliance than the hip. Raw accelerations were significantly higher for GAwrist compared with those for AGhip possibly because of placement location and technical differences between devices. AGhip PA calculated from raw accelerations and counts differed substantially, demonstrating that PA outcomes derived from cut points for raw output and counts cannot be directly compared.
引用
收藏
页码:245 / 253
页数:9
相关论文
共 48 条
  • [1] Children's Physical Activity Assessed with Wrist- and Hip-Worn Accelerometers
    Rowlands, Alex V.
    Rennie, Kirsten
    Kozarski, Robert
    Stanley, Rebecca M.
    Eston, Roger G.
    Parfitt, Gaynor C.
    Olds, Tim S.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2014, 46 (12): : 2308 - 2316
  • [2] Wear compliance, sedentary behaviour and activity in free-living children from hip-and wrist-mounted ActiGraph GT3X+accelerometers
    McLellan, Gillian
    Buchan, Duncan
    Arthur, Rosie
    JOURNAL OF PHYSICAL ACTIVITY & HEALTH, 2018, 15 (10): : S218 - S219
  • [3] Wear compliance, sedentary behaviour and activity in free-living children from hip-and wrist-mounted ActiGraph GT3X+accelerometers
    McLellan, Gillian
    Arthur, Rosie
    Buchan, Duncan S.
    JOURNAL OF SPORTS SCIENCES, 2018, 36 (21) : 2424 - 2430
  • [4] Raw Acceleration from Wrist- and Hip-Worn Accelerometers Corresponds with Mechanical Loading in Children and Adolescents
    Brailey, Gemma
    Metcalf, Brad
    Price, Lisa
    Cumming, Sean
    Stiles, Victoria
    SENSORS, 2023, 23 (15)
  • [5] Stride variability measures derived from wrist- and hip-worn accelerometers
    Urbanek, Jacek K.
    Harezlak, Jaroslaw
    Glynn, Nancy W.
    Harris, Tamara
    Crainiceanu, Ciprian
    Zipunnikov, Vadim
    GAIT & POSTURE, 2017, 52 : 217 - 223
  • [6] Algorithms to Improve Exercise Intensity Estimation by Using Wrist- and Hip-Worn Accelerometers and Treadmill Exercise
    Yang, Wen-Wen
    Lin, Yi-Chih
    Chien, Hsu-Fang Chang
    Shiang, Tzyy-Yuang
    Mccullen, Madelyn
    Chen, Vincent
    IEEE ACCESS, 2024, 12 : 121441 - 121448
  • [7] Compliance With Wearing Physical Activity Accelerometers in High School Students
    Sirard, John R.
    Slater, Megan E.
    JOURNAL OF PHYSICAL ACTIVITY & HEALTH, 2009, 6 : S148 - S155
  • [8] Compliance with Wearing Physical Activity Accelerometers in High School Students
    Sirard, John R.
    Slater, Megan E.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2008, 40 (05): : S208 - S208
  • [9] Comparison of Wrist- and Hip-Worn Activity Monitors When Meeting Step Guidelines
    Nelson, Rachael K.
    Hasanaj, Kristina
    Connolly, Gavin
    Millen, Laramy
    Muench, Joshua
    Bidolli, Nicole S. C.
    Preston, Michael A.
    Montoye, Alexander H. K.
    PREVENTING CHRONIC DISEASE, 2022, 19
  • [10] Validity of wrist worn accelerometers and comparability between hip and wrist placement sites in estimating physical activity behaviour in preschool children
    Hislop, Jane
    Palmer, Nicole
    Anand, Priya
    Aldin, Tara
    PHYSIOLOGICAL MEASUREMENT, 2016, 37 (10) : 1701 - 1714