DIMA-magnification mammography: use of phantoms for the investigation of image quality and radiation exposure.

被引:4
|
作者
Hermann, KP
Funke, M
Bruggemeyer, H
Sperner, W
Gruhl, T
Koch, R
机构
[1] UNIV GOTTINGEN, ZENTRUM RADIOL, RONTGENDIAGNOST ABT, D-37073 GOTTINGEN, GERMANY
[2] NIEDERSACHS LANDESAMT OKOL, HANNOVER, GERMANY
[3] FEINFOCUS MED TECH GMBH, GARBSEN, GERMANY
关键词
mammography; direct radiographic magnification; resolution; image contrast; radiation exposure;
D O I
10.1055/s-2007-1015535
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: A mammographic system has been developed to provide direct radiographic magnification; investigation of image quality and radiation exposure for surveys and aimed exposures were carried out on phantoms and the results compared with two modern screen methods. Material and method: Image quality was defined by contrast transfer function, resolution of low contrast, contrast of large areas and recognition of low contrast detail, using suitable phantoms. Measurements of entrance surface dose were made with a 1 cm(3) flat chamber. Results: For survey examinations, the new mammographic system provided image quality equal to a screen system but using 50% radiation dose. For localised views, the new system used similar radiation dose but provided significantly better demonstration of diagnostic detail. Conclusion: Using a focal spot of 40-120 mu m, the new mammographic system provides markedly improved direct radiographic magnification. With reduced radiation exposure at times, there is a significant gain in diagnostic information compared with current standard systems.
引用
收藏
页码:304 / 310
页数:7
相关论文
共 50 条
  • [1] Image quality and radiation exposure in digital storage plate mammography with magnification technique.
    Fiedler, E
    Aichinger, U
    Böhner, C
    Säbel, M
    Schulz-Wendtland, R
    Bautz, W
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1999, 171 (01): : 60 - 64
  • [2] IMAGE QUALITY AND RADIATION EXPOSURE IN MAMMOGRAPHY
    WOLF, G
    KALLINGER, G
    ACTA MEDICA AUSTRIACA, 1984, 11 (02) : 62 - 62
  • [3] IMAGE QUALITY IN A MAGNIFICATION MAMMOGRAPHY SYSTEM
    SKUCAS, J
    GORSKI, J
    LOGAN, W
    PHYSICS IN MEDICINE AND BIOLOGY, 1977, 22 (03): : 592 - 592
  • [4] EVALUATION OF MAMMOGRAPHY IMAGE QUALITY PHANTOMS
    YOUNG, KC
    RAMSDALE, ML
    RADIATION PROTECTION DOSIMETRY, 1993, 49 (1-3) : 171 - 173
  • [5] MAGNIFICATION FILM MAMMOGRAPHY - IMAGE QUALITY AND CLINICAL STUDIES
    SICKLES, EA
    DOI, K
    GENANT, HK
    RADIOLOGY, 1977, 125 (01) : 69 - 76
  • [6] EFFECTS OF A DEFECTIVE FILTER ON MAGNIFICATION IMAGE QUALITY IN MAMMOGRAPHY
    CARDENOSA, G
    EKLUND, GW
    RADIOLOGY, 1992, 182 (03) : 894 - 895
  • [7] IMAGE QUALITY AND RADIATION IN MAMMOGRAPHY
    EVANS, AL
    JAMES, WB
    MCLELLAN, J
    DAVISON, M
    BRITISH JOURNAL OF RADIOLOGY, 1975, 48 (576): : 1035 - 1036
  • [8] Image quality and dose in film-screen magnification mammography
    McParland, BJ
    BRITISH JOURNAL OF RADIOLOGY, 2000, 73 (874): : 1068 - 1077
  • [9] Comparison of image quality in contact and magnification modes in digital mammography
    Liu, B.
    MEDICAL PHYSICS, 2006, 33 (06) : 2014 - 2014
  • [10] Automated image quality assessment of mammography phantoms: a systematic review
    Alawaji, Zeyad
    Tavakoli Taba, Seyedamir
    Rae, William
    ACTA RADIOLOGICA, 2023, 64 (03) : 971 - 986