摘要
Significant improvements have been made in Positron Emission Tomography (PET) to enhance the image quality, namely, the development of time-of-flight (TOF) technology. This technique is useful to localize the emission point of the beta plus-emitter (beta(+)) radiopharmaceutical inside the body, allowing better lesion contrast and leading to a short scan time. The main goal of this study is to investigate the shortest acquisition time without compromising the image quality in both a NEMA body phantom and patients, using a TOF PET/Computed Tomography (PET/CT) scanner and the radionuclide Gallium-68 (Ga-68). Image quality parameters and quantification in terms of standardized uptake value (SUV) were acquired. A time between 45 and 60 s per bed position is proposed for future clinical practices.
引用
收藏
页码:27 / 42
页数:16
相关论文
共 50 条
  • [41] REDUCING THE TIME OF QC ON ECD WITHOUT COMPROMISING QUALITY
    Livori, A.
    Chan, G.
    Young, K.
    INTERNAL MEDICINE JOURNAL, 2017, 47 : 10 - 11
  • [42] Image quality measurement for evaluation of PET scanner performance
    Karp, JS
    Smith, RJ
    Muehllehner, G
    Daube-Witherspoon, ME
    Hines, H
    JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (05) : 133P - 134P
  • [43] Does the different radioactivity influence the effect of PSF and TOF correction on PET/CT image quality?
    Taniguchi, Takafumi
    Akamatsu, Go
    Kihara, Ken
    Kidera, Daisuke
    Mikasa, Shohei
    Tsutsui, Yuji
    Komiya, Isao
    Sasaki, Masayuki
    JOURNAL OF NUCLEAR MEDICINE, 2013, 54
  • [44] Improvement in PET/CT image quality in a 40 cm-large phantom with PSF and TOF
    Taniguchi, Takafumi
    Kasahara, Yukiko
    Mitsumoto, Katsuhiko
    Akamatsu, Go
    Himuro, Kazuhiko
    Komiya, Isao
    Ohya, Nobuyoshi
    Sasaki, Masayuki
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [45] Reduction of Cone-Beam CT scan time without compromising the accuracy of the image registration in IGRT
    Westberg, Jonas
    Jensen, Henrik R.
    Bertelsen, Anders
    Brink, Carsten
    ACTA ONCOLOGICA, 2010, 49 (02) : 225 - 229
  • [46] Effect of acquisition time on image quality in low-dose PET scanning
    Tanaka, A.
    Kubo, N.
    Akagi, H.
    Harada, T.
    Kameya, T.
    Kawai, Y.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 : S488 - S488
  • [47] A combined PET/CT scanner: the path to true image fusion
    Townsend, DW
    Beyer, T
    BRITISH JOURNAL OF RADIOLOGY, 2002, 75 : S24 - S30
  • [48] Geometrical interpretation of TOF PET raw data in commercial PET-CT scanner for SNR optimization
    Gianoli, C.
    De Bernardi, E.
    Kurz, C.
    Riboldi, M.
    Baroni, G.
    Parodi, K.
    RADIOTHERAPY AND ONCOLOGY, 2016, 118 : S46 - S46
  • [49] Simultaneous reconstruction of the activity image and registration of the CT image in TOF-PET
    Rezaei, Ahmadreza
    Michel, Christian
    Casey, Michael E.
    Nuyts, Johan
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (04): : 1852 - 1874
  • [50] Simultaneous Reconstruction of the Activity Image and Registration of the CT Image in TOF-PET
    Rezaei, Ahmadreza
    Nuyts, Johan
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,