Minimisation of Acquisition Time in a TOF PET/CT Scanner Without Compromising Image Quality

被引:0
|
作者
Oliveira, J. [1 ]
Parafita, R. [2 ]
Branco, S. [1 ]
机构
[1] Inst Politecn Lisboa, Escola Super Tecnol Saude Lisboa, Lisbon, Portugal
[2] Champalimaud Fdn, Lisbon, Portugal
来源
VIPIMAGE 2017 | 2018年 / 27卷
关键词
PET/CT; TOF; Ga-68; Acquisition time; Image quality; OF-FLIGHT;
D O I
10.1007/978-3-319-68195-5_4
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Significant improvements have been made in Positron Emission Tomography (PET) to enhance the image quality, namely, the development of time-of-flight (TOF) technology. This technique is useful to localize the emission point of the beta plus-emitter (beta(+)) radiopharmaceutical inside the body, allowing better lesion contrast and leading to a short scan time. The main goal of this study is to investigate the shortest acquisition time without compromising the image quality in both a NEMA body phantom and patients, using a TOF PET/Computed Tomography (PET/CT) scanner and the radionuclide Gallium-68 (Ga-68). Image quality parameters and quantification in terms of standardized uptake value (SUV) were acquired. A time between 45 and 60 s per bed position is proposed for future clinical practices.
引用
收藏
页码:27 / 42
页数:16
相关论文
共 50 条
  • [31] Time Resolution for Scattered and Unscattered Coincidences in a TOF PET Scanner
    Conti, Maurizio
    Rothfuss, Harold
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2010, 57 (05) : 2538 - 2544
  • [32] Linearity estimation of PET/CT scanner in list mode acquisition
    Choi, Hyeon Jun
    Kim, Byung Jin
    Ito, Mikiko
    Lee, Hong Jae
    Kim, Hyun Joo
    Lee, Jae Sung
    Lee, Dong Soo
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [33] Continuous bed motion acquisition for an LSO PET/CT scanner
    Townsend, DW
    Reed, J
    Newport, DF
    Carney, JPJ
    Tolbert, S
    Newby, D
    Yap, JT
    Long, MJ
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 2383 - 2387
  • [34] Improvements in PET Image quality from TOF PET/MRI
    Minamimoto, R.
    Jamali, M.
    Barkhodari, A.
    Holley, D.
    Zaharchuk, G.
    Levin, C.
    Iagaru, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 : S19 - S19
  • [35] Effect of acquisition time and matrix on the image quality in integrated PET/MR
    Wu, Tianqi
    Wu, Ping
    Zhuang, Jingwen
    Xie, Feng
    Li, Dong
    Dong, Shuo
    Bai, Mei
    JOURNAL OF NUCLEAR MEDICINE, 2016, 57
  • [36] Impact of acquisition time on diagnostic image quality in PET-scanning.
    Tietgen, N.
    Blom, H.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2006, 33 : S380 - S380
  • [37] Investigation on the influence of dose minimisation management on the PET image quality
    Hishar, H.
    Fikri, A. S. Fathinul
    Salasiah, M.
    Mohd, N. Noramaliza
    Jalil, N. Abdul
    RADIOGRAPHY, 2014, 20 (01) : 65 - 69
  • [38] Deep learning-based time-of-flight (TOF) PET image enhancement of non-TOF PET/CT scans
    Mehranian, A.
    Wollenweber, S. D.
    Walker, M. D.
    Bradley, K. M.
    Fielding, P.
    Huellner, M. W.
    Kotasidis, F.
    Su, K.
    Johnsen, R.
    Jansen, F.
    McGowan, D. R.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2021, 48 (SUPPL 1) : S325 - S326
  • [39] CT Scanner Hardware and Image Quality Assessment
    Dong, F.
    Fan, J.
    Schmidt, B.
    MEDICAL PHYSICS, 2015, 42 (06) : 3609 - 3610
  • [40] Comparative Analysis of Quality Control Tests of Traditional PET/CT scanner vs Total Body PET/CT Scanner
    Nguyen, Mike
    Hunt, Heather
    Caudle, Denise
    Schmall, Jeffrey
    Badawi, Ramsey
    Cherry, Simon
    JOURNAL OF NUCLEAR MEDICINE, 2020, 61