Confocal 3D Optical Intraoral Scanners and Comparison of Image Capturing Accuracy

被引:27
|
作者
Amornvit, Pokpong [1 ]
Rokaya, Dinesh [1 ]
Peampring, Chaimongkon [1 ]
Sanohkan, Sasiwimol [1 ]
机构
[1] Prince Songkla Univ, Fac Dent, Dept Prosthet Dent, Hat Yai 90110, Songkhla, Thailand
来源
CMC-COMPUTERS MATERIALS & CONTINUA | 2021年 / 66卷 / 01期
关键词
Confocal; intraoral scanners; accuracy; 3-dimensional analysis; teeth analysis; digital;
D O I
10.32604/cmc.2020.011943
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Several capture techniques are used in intraoral optical scanners in the dental market, such as Triangulation (Cerec Omnicam, Dentsply Sirona), Activewave front sampling (3M ESPE) and confocal technology (iTero, Align). The accuracy of intraoral scanners is the most significant focal point for developers to research. This in-vitro study studied the accuracy of confocal scanners launched from 2015-2020 (Trios 3, Trios 4, iTero Element; 3Shape Trios A/S, Copenhagen, Denmark, and iTero Element2, and iTero Element5D; Align Technologies, San Jose, CA, USA). A 3D printing model modified from the American National Standard No. 132 was scanned five times each scanner. Both Trios3 and Trios4 were scanned using regular scan mode (N) and high-resolution mode (HR). All scanning methods followed the recommendations from the manufacturers. Then the digital models were exported and saved as STL files. Various measurements were determined in the digital model from each scan using Rhinoceros 3D Software (Rhino, Robert McNeel & Associates for Windows, Washington DC, USA). Measurements from the 3D printed model were used as control. All data were recorded in Microsoft Excel and then transferred to SPSS. Descriptive statistics were recorded. Multiple comparisons of various measurements were made among the different scanners and with the control using One-way ANOVA and post hoc using Sheffe (p < 0.01). The surface area in the X and Y axis ranged from 2-60 mm, while the depth (Z-axis) ranged from 2-8 mm. The Trios and iTero families showed similar accuracy. However, for the diagonal, the Trios series showed better results compared with the iTero series. Within the same brand, different versions showed no significant change regarding accuracy.
引用
收藏
页码:303 / 314
页数:12
相关论文
共 50 条
  • [21] Accuracy of 3D Scanners in Tooth Mark Analysis
    Molina, Ana
    Martin-de-las-Heras, Stella
    JOURNAL OF FORENSIC SCIENCES, 2015, 60 : S222 - S226
  • [22] Accuracy, Time, and Comfort of Different Intraoral Scanners: An In Vivo Comparison Study
    Lione, Roberta
    De Razza, Francesca Chiara
    Gazzani, Francesca
    Lugli, Letizia
    Cozza, Paola
    Pavoni, Chiara
    APPLIED SCIENCES-BASEL, 2024, 14 (17):
  • [23] Evaluation and comparison of the accuracy of three intraoral scanners for replicating a complete denture
    Le Texier, Louise
    Nicolas, Emmanuel
    Batisse, Cindy
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 131 (04): : 706.e1 - 706.e8
  • [24] 3D image reconstruction using optical sectioning in confocal scanning microscopy
    Seo, JW
    Kang, DK
    Park, SL
    Gweon, DG
    OPTOMECHATRONIC SYSTEMS II, 2001, 4564 : 58 - 65
  • [25] Accuracy Comparison of the Optical 3D Scanner and CT Scanner
    Mendricky, Radomir
    Sobotka, Jiri
    MANUFACTURING TECHNOLOGY, 2020, 20 (06): : 791 - 801
  • [26] Comparison of the Accuracy of 3D Images Obtained from Different Types of Scanners: A Systematic Review
    Kustrzycka, Dorota
    Marschang, Tim
    Mikulewicz, Marcin
    Grzebieluch, Wojciech
    JOURNAL OF HEALTHCARE ENGINEERING, 2020, 2020
  • [27] Accuracy of 3D Printed and Digital Casts Produced from Intraoral and Extraoral Scanners with Different Scanning Technologies: In Vitro Study
    Ellakany, Passent
    Aly, Nourhan M.
    Al-Harbi, Fahad
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2022, 31 (06): : 521 - 528
  • [28] Comparison of the Accuracy of Intraoral Scanners Based on the Type of Tooth Preparation for a Single Crown
    Lee, Dong-Geun
    Son, Keunbada
    Lee, Kyu-Bok
    APPLIED SCIENCES-BASEL, 2021, 11 (20):
  • [29] 3D Anthropometric Facial Imaging-A comparison of different 3D scanners
    Koban, Konstantin Christoph
    Perko, Philipp
    Li, Zhouxiao
    Xu, Ya
    Giunta, Riccardo E.
    Alfertshofer, Michael G.
    Kohler, Lukas H.
    Freytag, David L.
    Cotofana, Sebastian
    Frank, Konstantin
    FACIAL PLASTIC SURGERY CLINICS OF NORTH AMERICA, 2022, 30 (02) : 149 - 158
  • [30] SCANNING ACCURACY AND PRECISION IN 4 INTRAORAL SCANNERS: AN IN VITRO COMPARISON BASED ON 3-DIMENSIONAL ANALYSIS
    Nedelcu, Robert G.
    Persson, Anna S. K.
    JOURNAL OF PROSTHETIC DENTISTRY, 2014, 112 (06): : 1461 - 1471